EMT6-K 269470 EATON MOELLER Thermistor overload relay for machine protection, 1N/O+1N/C, 24-240VAC/DC, witho.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EMT6-K 269470 EATON MOELLER Thermistor overload relay for machine protection, 1N/O+1N/C, 24-240VAC/DC, witho..

EMT6-K

269470

EATON - MOELLER

Available

Ship on today

Thermistor overload relay for machine protection, 1N/O+1N/C, 24-240VAC/DC, without reclosing lockout

More details


Contactor Relays

DIL Contactors - EATON - MOELLER

Thermistor Overload Relay EMT6 - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$52.24
3+$49.85
5+$48.98
7+$48.47
10+$48.10
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  EMT6 thermistor overload relay for machine protection
Function
  Without manual reset
Mains and fault LED display
Trip with short-circuit in the sensor cable
Test button
Rated operational current
   
AC-15
   
240 V
IeA3
AC--14
   
300 V
IeA3
400 V
IeA3
 
  Value applies starting with release 001.
conventional thermal current
IthA6
Rated control voltage
UsV24 - 240 V 50 - 400 Hz
24 - 240 V DC
Notes 

General
Standards
  IEC/EN 60947, VDE 0660, EN 55011
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +60
Enclosed
 °C- 25 - 45
Storage
 °C- 45 - 85
Mounting position
  As required
Weight
 kg0.15
Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27
 g10
Degree of Protection
  IP20
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Safe isolation to EN 61140
   
between the contacts
 V AC250
between contacts and power supply
 V AC250
Auxiliary and control circuits
Rated impulse withstand voltage
UimpV AC4000
Rated impulse withstand voltage
UimpV AC6000
 
  Value applies starting with release 001.
Overvoltage category/pollution degree
  III/3
Terminal capacities Auxiliary and control circuits
   
Solid
 mm21 x (0.5 - 2.5)
2 x (0.5 - 1.5)
Flexible with ferrule
 mm21 x (0.5 - 2.5)
2 x (0.5 - 1.5)
Solid or stranded
 AWG20 - 14
Terminal screw
  M3.5
Tightening torque
 Nm1.2
Tools
   
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm1 x 6
Auxiliary power circuit
Rated insulation voltage
UiV300
Rated insulation voltage
UiV400
 
  Value applies starting with release 001.
Rated operational current
IeA 
AC--14
   
Make contact
   
300 V
IeA3
380 V 400 V 415 V
IeA3
 
  Value applies starting with release 001.
Break contact
   
300 V
IeA3
380 V 400 V 415 V
IeA3
 
  Value applies starting with release 001.
AC-15
   
Make contact
   
220 V 230 V 240 V
IeA3
300 V
IeA1
380 V 400 V 415 V
IeA1
 
  Value applies starting with release 001.
Break contact
   
220 V 230 V 240 V
IeA3
300 V
IeA1
380 V 400 V 415 V
IeA1
 
  Value applies starting with release 001.
Max. short-circuit protective device
   
Fuse
gG/gLA6
Control circuit
Rated insulation voltage
UiV240
Rated operational voltage
UeV240
Pick-up and drop-out values
 x Ue0.85 - 1.1
Power consumption
   
AC
 VA3.5
DC
 W2
Trip at approx.
 3600
Recovery at approx.
 1600
Electromagnetic compatibility (EMC)
Electrostatic discharge (ESD)
   
applied standard
  IEC/EN 61000-4-2
Air discharge
 kV8
Contact discharge
 kV6
Electromagnetic fields (RFI)
   
applied standard
  IEC/EN 61000-4-3
 
 V/m80 - 1000 MHz: 10
1.4 - 2 GHz: 3
2.0 - 2.7 GHz: 1
Radio interference suppression
  EN 55011
Class B
Burst
 kVSupply cables: 2
Signal cables: 1
according to IEC/EN 61000-4-4
power pulses (Surge)
  2 kV (symmetrical)
4 kV (asymmetrical)
according to IEC/EN 61000-4-5
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
 V10
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C60
Technical data ETIM 6.0(Show features)(Hide features)
Relays (EG000019) / Temperature monitoring relay (EC001446)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Monitoring equipment (low-voltage switch technology) / Temperature monitoring equipment ([email protected] [AKF104011])
Type of electric connection
  Screw connection
Rated control supply voltage Us at AC 50HZ
 V24 - 240
Rated control supply voltage Us at AC 60HZ
 V24 - 240
Rated control supply voltage Us at DC
 V24 - 240
Voltage type for actuating
  AC/DC
With detachable clamps
  No
Number of measuring circuits
  1
Error registration possible
  No
External reset possible
  No
Number of contacts as normally closed contact
  1
Number of contacts as normally open contact
  1
Number of contacts as change-over contact
  0
Width
 mm23
Height
 mm84
Depth
 mm104
Approvals
Product Standards  UL 508; CSA-C22.2 No. 14; IEC/EN 60947-8; CE marking
UL File No.  E29184
UL Category Control No.  NKCR
CSA File No.  12528
CSA Class No.  3211-03
North America Certification  UL listed, CSA certified
Specially designed for North America  No
Max. Voltage Rating  600 V AC
Degree of Protection  IEC: IP20, UL/CSA Type: -
Characteristics
IL03407100Z (AWA2327-1454) thermistor overload relay for machine protection
 
>
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or