T5-5-8361/E 095280 EATON MOELLER Changeoverswitches, Contacts: 10, 100 A, front plate: 1-0-2, 60 °, maintain.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

T5-5-8361/E 095280 EATON MOELLER Changeoverswitches, Contacts: 10, 100 A, front plate: 1-0-2, 60 °, maintain..

T5-5-8361/E

095280

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Changeoverswitches, Contacts: 10, 100 A, front plate: 1-0-2, 60 °, maintained, flush mounting

More details


Switches

T Cam switches and P Switch-disconnectors - EATON - MOELLER

Switch-disconnectors - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$223.84
2+$218.60
3+$216.00
4+$215.51
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Control switches
Part group reference
  T5
Basic function
  Changeoverswitches
 
  with black thumb grip and front plate
Contacts
  10
Degree of Protection
  Front IP65
Design
  flush mounting
 
  
General
Standards
  IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +50
Enclosed
 °C-25 - +40
Overvoltage category/pollution degree
  III/3
Rated impulse withstand voltage
UimpV AC6000
Mechanical shock resistance
 g15
Mounting position
  As required
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Contacts
Electrical characteristics
   
Rated operational voltage
UeV AC690
Rated uninterrupted current
IuA100
Note on rated uninterrupted current !u
  Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
   
AB 25 % DF
 x Ie2
AB 40 % DF
 x Ie1.6
AB 60 % DF
 x Ie1.3
Short-circuit rating
   
Fuse
 A gG/gL100
Rated short-time withstand current (1 s current)
IcwArms1700
Note on rated short-time withstand current lcw
  Current for a time of 1 second
Rated conditional short-circuit current
IqkA2
Switching capacity
cos ϕ rated making capacity as per IEC 60947-3
 A950
Rated breaking capacity cos ϕ to IEC 60947-3
 A 
230 V
 A760
400/415 V
 A740
500 V
 A590
690 V
 A420
Safe isolation to EN 61140
   
between the contacts
 V AC440
Current heat loss per contact at Ie
 W7.5
Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
 CO7.5
Lifespan, mechanical
Operationsx 106> 0.5
Maximum operating frequency
Operations/h 1200
AC
   
AC-3
   
Rating, motor load switch
PkW 
220 V 230 V
PkW22
230 V Star-delta
PkW30
400 V 415 V
PkW30
400 V Star-delta
PkW45
500 V
PkW30
500 V Star-delta
PkW45
690 V
PkW15
690 V Star-delta
PkW22
Rated operational current motor load switch
   
230 V
IeA71
230 V star-delta
IeA100
400V 415 V
IeA55
400 V star-delta
IeA95.3
500 V
IeA44
500 V star-delta
IeA76.2
690 V
IeA17
690 V star-delta
IeA29.4
AC-21A
   
Rated operational current switch
   
440 V
IeA100
AC-23A
   
Motor rating AC-23A, 50 - 60 Hz
PkW 
230 V
PkW30
400 V 415 V
PkW55
500 V
PkW37
690 V
PkW30
Rated operational current motor load switch
   
230 V
IeA100
400 V 415 V
IeA100
500 V
IeA55
690 V
IeA32
DC
   
DC-1, Load-break switches L/R = 1 ms
   
Rated operational current
IeA80
Voltage per contact pair in series
 V60
Control circuit reliability at 24 V DC, 10 mA
Fault probabilityHF< 10 -5, < 1 fault in 100000 operations
Terminal capacities
Solid or stranded
 mm21 x (2,5 - 35)
2 x (2,5 - 16)
Flexible with ferrules to DIN 46228
 mm21 x (1 - 25)
2 x (1.5 - 10)
Terminal screw
  M6
Max. tightening torque
 Nm4
Technical safety parameters:
Notes
  B10d values as per EN ISO 13849-1, table C1
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA100
Heat dissipation per pole, current-dependent
PvidW7.5
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C50
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Please enquire
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Off-load switch (EC001105)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Changeover switch ([email protected] [AKF062010])
Model
  Reverser
Number of poles
  5
With 0 (off) position
  Yes
With retraction in 0-position
  No
Rated permanent current Iu
 A100
Rated operation current Ie at AC-3, 400 V
 A55
Rated operation power at AC-3, 400 V
 kW30
Degree of protection (IP), front side
  IP65
Number of auxiliary contacts as normally closed contact
  0
Number of auxiliary contacts as normally open contact
  0
Number of auxiliary contacts as change-over contact
  0
Suitable for ground mounting
  No
Suitable for front mounting 4-hole
  Yes
Suitable for distribution board installation
  No
Suitable for intermediate mounting
  No
Complete device in housing
  No
Type of control element
  Toggle
Type of electrical connection of main circuit
  Screw connection
Dimensions
IL03801009Z (AWA1150-1692) Cam switches: switch-disconnectors
 
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or