IN32S4-32W-1100V 123872 EATON MOELLER Int-Isolator, 4P, 3200A, 1100V, removable without chassis

IN32S4-32W-1100V

123872

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Int-Isolator, 4P, 3200A, 1100V, removable without chassis

More details


Circuit-breakers IZM - EATON - MOELLER

IN switch-disconnectors - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

Up to 35% discount for registered clients. * This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.
EXPRESS quotation request, you will get an answer in a few minutes

IN32S4-32W-1100V 123872 EATON MOELLER Int-Isolator, 4P, 3200A, 1100V, removable without chassis

Enter your contact details and submit your request, you will be notified by email with a quotation. You simply finish your order and you will receive the products.






* Required fields

or 

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Air circuit-breakers/switch-disconnectors
Product range
  Open switch-disconnectors for 1100 V AC
Current Range
  over 4000 A
Protective function
  Switch disconnector
Installation type
  Withdrawable
Construction size
  IN32S
Release system
  Electronic release
Standard/Approval
  IEC
Number of poles
  4 pole
Degree of Protection
  IP20, IP55 with protective cover
Rated current = rated uninterrupted current
In = IuA3200
Making capacity Icm to 440 V 50/60 Hz
IcmkA210
Notes 

Including rear connection main terminals and secondary terminal blocks according to ordered breaker options.

Note concerning the product 

Cassette needs to be ordered separately.

Technical data
General
Standards
  IEC/EN 60947
Ambient temperature
   
Storage
ϑ°C-40 - +70
Operating (open)
 °C-25 - +70
Mounting position
  >>
Utilization category
  B
Degree of Protection
  IP20, IP55 with protective cover
Direction of incoming supply
  as required
Main conducting paths
Rated current = rated uninterrupted current
In = IuA3200
Rated uninterrupted current at 50 °C
IuA3100
Rated uninterrupted current at 60 °C
IuA2800
Rated uninterrupted current at 70 °C
IuA2550
Rated impulse withstand voltage
UimpV AC8000
Rated operational voltage
UeV AC690
Use in IT electrical power networks up to U = 440 V
IITkA39
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV1100
Switching capacity
Rated short-circuit making capacity
Icm  
up to 440 V 50/60 Hz
IcmkA210
up to 690 V 50/60 Hz
IcmkA53
Operating times
   
Closing delay via spring release
 ms35
Break times
 ms40
Total opening delay via shunt release
 ms30
Total opening delay via undervoltage release
 ms35/70
Maximum operating frequency
 Ops./h 
Maximum operating frequency
Operations/h 60
Heat dissipation at rated current In
   
Fixed mounting
 W320
Withdrawable units (switch with cassette)
 W800
Weight
Fixed mounting
   
3-pole
 kg70
4-pole
 kg89
Withdrawable
   
3-pole
 kg88
4-pole
 kg115
Cassette
   
3 pole
 kg60
4 pole
 kg73
Terminal capacities
Copper bar
   
Fixed mounting
   
Black
 mm3 x 10 x 100
Withdrawable units
   
Black
 mm3 x 10 x 100
 
  

Permissible continuous current for circuit‐breakers operating in switchboards at various internal ambient temperatures. The switchboard’s internal ambient temperature should be estimated using the calculation methods of IEC regulation.

Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
Dimensions
>
>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or