DMM125/4 +CM 1314207 EATON MOELLER Switch-disconnector, 4 pole, 125 A, With blue rotary handle (Type C) and .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DMM125/4 +CM 1314207 EATON MOELLER Switch-disconnector, 4 pole, 125 A, With blue rotary handle (Type C) and ..

DMM125/4 +CM

1314207

EATON - MOELLER

Available

Ship on today

Switch-disconnector, 4 pole, 125 A, With blue rotary handle (Type C) and drive shaft, flush mounting, Vertical connection

More details


Isolator Switch Isolation

DUMECO Switch-Disconnectors- EATON - MOELLER

DUMECO Switch-Disconnectors- EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$193.79
2+$189.07
3+$186.73
4+$185.51
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Switch-disconnector
Main switch
maintenance switch
Part group reference
  DMM
 
  With blue rotary handle (Type C) and drive shaft
Information about equipment supplied
  auxiliary contact fitted by user.
Number of poles
  4 pole
Auxiliary contacts
   
 
General
Standards
  IEC/EN 60947, VDE 0660, IEC/EN 60204,
Switch-disconnector according to IEC/EN 60947-3
Certifications
  CE, RoHs, KEMA, GOST-R, Lloyds
Ambient temperature
   
Operation
ϑ°C-25 - +55
Storage
ϑ°C-30 - +80
Overvoltage category/pollution degree
  III/3
Rated impulse withstand voltage
UimpkV6
Rated insulation voltage
UiV1000
Mounting position
  As required
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Contacts
Mechanical variables
   
Number of poles
  4 pole
Auxiliary contacts
   
 
 N/O0
 
 N/C0
Electrical characteristics
   
Rated operational voltage
UeV AC690
Rated uninterrupted current
IuA125
Note on rated uninterrupted current !u
  Rated uninterrupted current Iu is specified for max. cross-section.
Short-circuit rating
   
fuse
  125
Rated conditional short-circuit current
IqkA50
Breaking current
 kA14.5
max. let-through energy
 kA²s140
Rated short-time withstand current (1 s current)
IcwArms2500
Note on rated short-time withstand current lcw
  Current for a time of 1 second
Switching capacity
Rated breaking capacity cos ϕ to IEC 60947-3
 A 
400/415 V
 A480
500 V
 A520
690 V
 A352
Safe isolation to EN 61140
   
Current heat loss per contact at Ie
 W4.5
Lifespan, mechanical
Operations 10000
AC
   
AC-21A
   
Rated operational current switch
   
400 V 415 V
IeA125
500 V
IeA125
690 V
IeA125
AC-22A
   
Rated operational current switch
   
400 V 415 V
IeA125
500 V
IeA125
690 V
IeA125
AC-23A
   
Rated operational current switch
   
400 V 415 V
IeA60
500 V
IeA65
690 V
IeA44
Motor rating AC-23A, 50 - 60 Hz
PkW 
400 V 415 V
PkW30
500 V
PkW45
690 V
PkW40
Terminal capacities
Flexible with ferrules to DIN 46228
 mm2 
flexible
 mm26 - 70
Max. tightening torque
 Nm7
Technical safety parameters:
Notes
  B10d values as per EN ISO 13849-1, table C1
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA125
Heat dissipation per pole, current-dependent
PvidW4.5
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C55
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ([email protected] [AKF060010])
Version as main switch
  No
Version as maintenance-/service switch
  No
Version as safety switch
  No
Version as emergency stop installation
  No
Version as reversing switch
  No
Max. rated operation voltage Ue AC
 V690
Rated operating voltage
 V690 - 690
Rated permanent current Iu
 A125
Rated permanent current at AC-21, 400 V
 A125
Rated operation power at AC-3, 400 V
 kW0
Rated short-time withstand current lcw
 kA2.5
Rated operation power at AC-23, 400 V
 kW30
Switching power at 400 V
 kW0
Conditioned rated short-circuit current Iq
 kA50
Number of poles
  4
Number of auxiliary contacts as normally closed contact
  0
Number of auxiliary contacts as normally open contact
  0
Number of auxiliary contacts as change-over contact
  0
Motor drive optional
  No
Motor drive integrated
  No
Voltage release optional
  No
Device construction
  Built-in device fixed built-in technique
Suitable for ground mounting
  Yes
Suitable for front mounting 4-hole
  No
Suitable for front mounting center
  No
Suitable for distribution board installation
  No
Suitable for intermediate mounting
  Yes
Colour control element
  -
Type of control element
  Toggle
Interlockable
  No
Type of electrical connection of main circuit
  Screw connection
Degree of protection (IP), front side
  IP20
Dimensions
>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or