DMM-63/1+SK 1314159 EATON ELECTRIC Switch-disconnector, 3 pole + N, 63 A, With blue rotary handle (Type C) a.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DMM-63/1+SK 1314159 EATON ELECTRIC Switch-disconnector, 3 pole + N, 63 A, With blue rotary handle (Type C) a..

DMM-63/1+SK

1314159

EATON-MOELLER

Switch-disconnector, 3 pole + N, 63 A, With blue rotary handle (Type C) and drive shaft, flush mounting, Vertical connection

DMM-63/1+SK

Switch-disconnector, DMM, 63 A, 3P + N (solid), With blue rotary handle (Type C) and drive shaft, Vertical connection

More details


Low-voltage industrial components > Switch disconnector

DUMECO Switch-Disconnectors

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $186.80
Unit price: $186.80

Quantity Price
1+$186.80
2+$171.41
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Switch-disconnector, DMM, 63 A, 3P + N (solid), With blue rotary handle (Type C) and drive shaft, Vertical connection
Switch-disconnector, Product range: Switch-disconnector, Main switch, maintenance switch, Part group reference: DMM, With blue rotary handle (Type C) and drive shaft, Information about equipment supplied: auxiliary contact fitted by user., 3 pole + SN (direct), Notes: 1 padlock, 5 mm, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP20, Design: flush mounting, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 30 kW, Rated uninterrupted current: Iu = 63 A, Connection technique: Vertical connection, Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3

Delivery program

Product range
Switch-disconnector
Main switch
maintenance switch
Part group reference
DMM
With blue rotary handle (Type C) and drive shaft
Information about equipment supplied
auxiliary contact fitted by user.
Number of poles
3P + N (solid)
Auxiliary contacts
0 N/O
0 N/C
Notes
1 padlock, ∅ 5 mm
Locking facility
Lockable in the 0 (Off) position
Degree of Protection
IP20
Design
flush mounting
000Z427
Contact sequence
1150SWI-39
Motor rating AC-23A, 50 - 60 Hz [P]
400 V [P]
30 kW
Rated uninterrupted current [Iu]
63 A
Note on rated uninterrupted current !u
Rated uninterrupted current Iuis specified for max. cross-section.
Connection technique
Vertical connection

Technical data

General
Standards
IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Certifications
CE, RoHs, KEMA, EAC, Lloyds
Ambient temperatureOperation [ϑ]
-25 - +55 °C
Ambient temperatureStorage [ϑ]
-30 - +80 °C
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage [Uimp]
6 kV
Rated insulation voltage [Ui]
1000 V
Mounting position
As required
Contacts
Mechanical variablesNumber of poles
3P + N (solid)
Mechanical variablesAuxiliary contacts
0 N/O
Mechanical variablesAuxiliary contacts
0 N/C
Electrical characteristicsRated operational voltage [Ue]
690 V AC
Electrical characteristicsRated uninterrupted current [Iu]
63 A
Electrical characteristicsNote on rated uninterrupted current !u
Rated uninterrupted current Iuis specified for max. cross-section.
Short-circuit ratingfuse
80/50
Short-circuit ratingRated conditional short-circuit current [Iq]
In = 80: 50
In = 50: 100 kA
Short-circuit ratingBreaking current
In = 80: 9.7
In = 50: 9.6 kA
Short-circuit ratingmax. let-through energy
In = 80: 44
In = 50: 10 kA²s
Rated short-time withstand current (1 s current) [Icw]
1500 Arms
Note on rated short-time withstand current lcw
Current for a time of 1 second
Heat dissipation per pole, current-dependent [Pvid]
6 W
Switching capacity
Rated breaking capacity cos ϕ to IEC 60947-3400/415 V
504 A
Rated breaking capacity cos ϕ to IEC 60947-3500 V
264 A
Rated breaking capacity cos ϕ to IEC 60947-3690 V
200 A
Safe isolation to EN 61140Current heat loss per contact at Ie
6 W
Lifespan, mechanical [Operations]
8500
ACAC-21ARated operational current switch400 V 415 V [Ie]
63 A
ACAC-21ARated operational current switch500 V [Ie]
63 A
ACAC-21ARated operational current switch690 V [Ie]
63 A
ACAC-22ARated operational current switch400 V 415 V [Ie]
63 A
ACAC-22ARated operational current switch500 V [Ie]
63 A
ACAC-22ARated operational current switch690 V [Ie]
63 A
ACAC-23ARated operational current switch400 V 415 V [Ie]
63 A
ACAC-23ARated operational current switch500 V [Ie]
33 A
ACAC-23ARated operational current switch690 V [Ie]
25 A
ACAC-23AMotor rating AC-23A, 50 - 60 Hz [P]400 V 415 V [P]
30 kW
ACAC-23AMotor rating AC-23A, 50 - 60 Hz [P]500 V [P]
22 kW
ACAC-23AMotor rating AC-23A, 50 - 60 Hz [P]690 V [P]
22 kW
Terminal capacities
Solid
2.5 - 16 mm2
Flexible with ferrules to DIN 46228flexible
1.5 - 25 mm2
Stripping length
14 mm
Tightening torque for terminal screw
2 Nm
Technical safety parameters:
Notes
B10dvalues as per EN ISO 13849-1, table C1

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
63 A
Heat dissipation per pole, current-dependent [Pvid]
6 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ([email protected] [AKF060013])
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as emergency stop installation
No
Version as reversing switch
No
Number of switches
1
Max. rated operation voltage Ue AC
690 V
Rated operating voltage
690 - 690 V
Rated permanent current Iu
63 A
Rated permanent current at AC-23, 400 V
40 A
Rated permanent current at AC-21, 400 V
63 A
Rated operation power at AC-3, 400 V
0 kW
Rated short-time withstand current lcw
1.5 kA
Rated operation power at AC-23, 400 V
30 kW
Switching power at 400 V
0 kW
Conditioned rated short-circuit current Iq
100 kA
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Motor drive integrated
No
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Suitable for ground mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Suitable for distribution board installation
Yes
Suitable for intermediate mounting
No
Colour control element
Other
Type of control element
Toggle
Interlockable
No
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
Degree of protection (NEMA)
Other

Dimensions

1150DIM-43

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.