QM100/3 1319815 EATON MOELLER Switch-disconnector, 3p, 100A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

QM100/3 1319815 EATON MOELLER Switch-disconnector, 3p, 100A

QM100/3

1319815

EATON - MOELLER

Available

Ship on today

Switch-disconnector, 3p, 100A

More details


Isolator Switch Isolation

DUMECO Switch-Disconnectors- EATON - MOELLER

DUMECO Switch-Disconnectors- EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$158.30
2+$154.24
3+$152.23
4+$150.95
5+$150.36
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Changeover switches
Part group reference
  QM
Emergency STOP
  optional
 
  without rotary handle
With drive shaft, 6 mm square
Information about equipment supplied
  Auxiliary contact or neutral conductor fitted by user.
Number of poles
  2 x 3 pole
Auxiliary contacts
   
 
General
Standards
  IEC/EN 60947, VDE 0660, IEC/EN 60204,
Switch-disconnector according to IEC/EN 60947-3
Certifications
  CE, RoHs
Overvoltage category/pollution degree
  III/3
Mounting position
  As required
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Contacts
Mechanical variables
   
Number of poles
  2 x 3 pole
Auxiliary contacts
   
 
 N/O0
 
 N/C0
Electrical characteristics
   
Rated uninterrupted current
IuA100
Note on rated uninterrupted current !u
  Rated uninterrupted current Iu is specified for max. cross-section.
Switching capacity
Safe isolation to EN 61140
   
Current heat loss per contact at Ie
 W8
Technical safety parameters:
Notes
  B10d values as per EN ISO 13849-1, table C1
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA100
Heat dissipation per pole, current-dependent
PvidW8
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Dimensions
>