SPC-S-20/335/3 248178 EATON ELECTRIC Changeoverswitches, Contacts: 4, 20 A, front plate: 1-0-2, 45 °, mainta..

SPC-S-20/335/3

248178

EATON-MOELLER

Changeoverswitches, Contacts: 4, 20 A, front plate: 1-0-2, 45 °, maintained, service distribution board mounting

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Change-over Contacts: 4, 20 A, plate: 1-0-2, 45 °, hanging, wall Mounting table, modular
Selector, Range: command Switches, type Identifier: T0, with black controller and plate, Contacts: 4, Degree of protection: front IP30, Shape: recessed Mounting in table, modular Angles of rotation: 45 °, cut-off Behavior: for hanging, with " 0 " position, plate: 1-0-2, rated Power employment AC-23A, 50 - 60 Hz 400 V: P = 5.5 kW, rated Current continuous: Iu = 20 A, 2 Cake(s), Compliance with standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, switch-disconnectors according to IEC/EN 60947-3
[

Range of delivery

Range
Command switches
Type identifier
T0
Basic function
Inverters
with black controller and plate
Contacts
Four
Degree of protection
Front side IP30
Form
Flush mounting in table, modular
Schema
Angles of rotation
45 °
Cut-off behavior
to snap
with position " 0 "
N° of plastron
plastron
1-0-2
Rated power of employment AC-23A, 50 - 60 Hz [P]
400 V [P]
5.5 kW
Rated current continuous [Iu]
Twenty
Note on the rated current continuous Iu
Rated current continuous Iuspecified for the maximum section.
Number of patties
2 Cake(s)
,

Technical characteristics

General
Compliance with standards
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnectors according to IEC/EN 60947-3
Climate resilience
Damp heat, constant according to IEC 60068-2-78
Damp heat, cyclical, according to IEC 60068-2-30
Ambient temperatureopen
-25 - +50 °C
Ambient temperaturein an envelope
-25 - +40 °C
Overvoltage category/pollution Degree
III/3
Voltage withstand [Uimp]
6000 V AC
Shock
15 g
Mounting Position
Any
Electrical Circuits
Electrical characteristicsRated voltage of employment [Ue]
690 V AC
Electrical characteristicsRated current continuous [Iu]
Twenty
Electrical characteristicsNote on the rated current continuous Iu
Rated current continuous Iuspecified for the maximum section.
Load max. eligible in-service intermittent, Class 12IF 25 % FM
2 x Ie
Load max. eligible in-service intermittent, Class 12IF 40 % FM
1.6 x Ie
Load max. eligible in-service intermittent, Class 12IF 60 % FM
1.3 x Ie
Resistance to short-circuitswith fuse
20 A gG/gL
Rated short-time current (1 s) [Icw]
320 Aeff
Note on the rated short-time current eligible Icw
current 1 second
Short-circuit current, conditional [Iq]
6 kA
Power cut-off
Rated closing cos ϕ according to IEC 60947-3
130 A
Rated breaking cos ϕ according to IEC 60947-3230 V
One hundred
Rated breaking cos ϕ according to IEC 60947-3400 / 415v V
110 A
Rated breaking cos ϕ according to IEC 60947-3500 V
Eighty
Rated breaking cos ϕ according to IEC 60947-3690 V
Sixty
Reliable separation according to EN 61140between the contacts
440 V AC
Reliable separation according to EN 61140Losses by the Joule effect by circuit (Ie
0.6 W
Reliable separation according to EN 61140Losses by the Joule effect by electric circuit auxiliary under Ie(AC-15/230 V)
0.6 W
Durability mechanical [maneuvers]
> 0.4 x 10Six
Frequency of maneuvers max. [Man./h]
One thousand two hundred
Ac voltageAC-3Rated power job starter [P]220 V 230 V [P]
3 kW
Ac voltageAC-3Rated power job starter [P]230 V star-delta [P]
5.5 kW
Ac voltageAC-3Rated power job starter [P]400 V 415 [P]
5.5 kW
Ac voltageAC-3Rated power job starter [P]400 V star-delta [P]
7.5 kW
Ac voltageAC-3Rated power job starter [P]500 V [P]
5.5 kW
Ac voltageAC-3Rated power job starter [P]500 V star-delta [P]
7.5 kW
Ac voltageAC-3Rated power job starter [P]690 V [P]
4 kW
Ac voltageAC-3Rated power job starter [P]690 V star-delta [P]
5.5 kW
Ac voltageAC-3Rated current job, start switch engine230 V [Ie]
11.5 A
Ac voltageAC-3Rated current job, start switch engine230 V star-delta [Ie]
Twenty
Ac voltageAC-3Rated current job, start switch engine400V 415 V [Ie]
11.5 A
Ac voltageAC-3Rated current job, start switch engine400 V star-delta [Ie]
Twenty
Ac voltageAC-3Rated current job, start switch engine500 V [Ie]
Nine
Ac voltageAC-3Rated current job, start switch engine500 V star-delta [Ie]
15.6 A
Ac voltageAC-3Rated current job, start switch engine690 V [Ie]
4.9 A
Ac voltageAC-3Rated current job, start switch engine690 V star-delta [Ie]
8.5. A
Ac voltageAC-21ACurrent assigned job switch440 V [Ie]
Twenty
Ac voltageAC-23ARated power of employment AC-23A, 50 - 60 Hz [P]230 V [P]
3 kW
Ac voltageAC-23ARated power of employment AC-23A, 50 - 60 Hz [P]400 V 415 V [P]
5.5 kW
Ac voltageAC-23ARated power of employment AC-23A, 50 - 60 Hz [P]500 V [P]
7.5 kW
Ac voltageAC-23ARated power of employment AC-23A, 50 - 60 Hz [P]690 V [P]
5.5 kW
Ac voltageAC-23ARated current job, start switch engine230 V [Ie]
13.3 A
Ac voltageAC-23ARated current job, start switch engine400 V 415 V [Ie]
13.3 A
Ac voltageAC-23ARated current job, start switch engine500 V [Ie]
13.3 A
Ac voltageAC-23ARated current job, start switch engine690 V [Ie]
7.6 Has
Tension continuesDC-1, switches L/R = 1 msRated current of employment [Ie]
Ten
Tension continuesDC-1, switches L/R = 1 msVoltage per contact series
60 V
Tension continuesDC-21A, [Ie]Rated current of employment [Ie]
One
Tension continuesDC-21A, [Ie]Contacts
1 Number
Tension continuesDC-23A, motor starters, L/R = 15 ms24 VRated current of employment [Ie]
Ten
Tension continuesDC-23A, motor starters, L/R = 15 ms24 VContacts
1 Number
Tension continuesDC-23A, motor starters, L/R = 15 ms48 VRated current of employment [Ie]
Ten
Tension continuesDC-23A, motor starters, L/R = 15 ms48 VContacts
2 Number
Tension continuesDC-23A, motor starters, L/R = 15 ms60 VRated current of employment [Ie]
Ten
Tension continuesDC-23A, motor starters, L/R = 15 ms60 VContacts
3 Number
Tension continuesDC-23A, motor starters, L/R = 15 ms120 VRated current of employment [Ie]
Five
Tension continuesDC-23A, motor starters, L/R = 15 ms120 VContacts
3 Number
Tension continuesDC-23A, motor starters, L/R = 15 ms240 VRated current of employment [Ie]
Five
Tension continuesDC-23A, motor starters, L/R = 15 ms240 VContacts
5 Number
Tension continuesDC-13, command switches L/R = 50 msRated current of employment [Ie]
Ten
Tension continuesDC-13, command switches L/R = 50 msVoltage per contact series
32 V
Reliability of the contacts 24 V DC, 10 mA [dud Rate]
< 10-5, < 1 missed on 100000 maneuvers HF
Sections connectable
soul massive or multi-stranded
1 x (1 - 2,5)
2 x (1 - 2.5) mmTwo
With a flexible tip according to DIN 46228
1 x (0,75 - 2,5)
2 x (0,75 - 2,5) mmTwo
Connecting screws
M3,5
Tightening torque screw connection
1 Nm
The characteristic variables in the domain of security
Notes
Values B10daccording to EN ISO 13849-1, table C1
Electrical characteristics approved
Electrical CircuitsRated voltage of employment [Ue]
600 V AC
Electrical CircuitsRated current continuous max.Main circuitGeneral use
16 A
Electrical CircuitsRated current continuous max.Auxiliary CircuitsGeneral Use [IU]
Ten
Electrical CircuitsRated current continuous max.Auxiliary CircuitsPilot Duty
Six hundred
P 600
Power cut-offEngine power maximumsingle-phase120 V AC
0.5 HP
Power cut-offEngine power maximumsingle-phase200 V AC
1 HP
Power cut-offEngine power maximumsingle-phase240 V AC
1.5 HP
Power cut-offEngine power maximumthree-phase200 V AC
3 HP
Power cut-offEngine power maximumthree-phase240 V AC
3 HP
Power cut-offEngine power maximumthree-phase480 V AC
7.5 HP
Power cut-offEngine power maximumthree-phase600 V AC
7.5 HP
Short Circuit Current RatingNominal value
5 kA
Short Circuit Current Ratingmax. Fuse
Fifty
Short Circuit Current RatingNominal default high
10 kA
Short Circuit Current Ratingmax. Fuse
20, Class J Has
Sections connectableto soul massive or flexible with ferrule
18 - 14 AWG
Sections connectableConnecting screws
M3,5
Sections connectableTightening torque
8.8 lb-in
,

Design verification according to IEC/EN 61439

Technical specifications for verification of design
Rated current job for indication of the power dissipated [In]
Twenty
Power dissipated per pole, according to the current [Pvid]
0.6 W
Power dissipated in the material, a function of the current [Pvid]
0 W
Power dissipated static, dependent on the current [Pvs]
0 W
Power issue of power dissipation [Pve]
0 W
Temperature of use min.
-25 °C
Working temperature max.
+50 °C
Certificate for IEC/EN 61439
10.2 Strength of materials and parts10.2.2 Resistance to corrosion
The requirements of the product standard are met.
10.2 Strength of materials and parts10.2.3.1 heat Resistance of the envelope
The requirements of the product standard are met.
10.2 Strength of materials and parts10.2.3.2 Resistance of insulating Materials to Heat normal
The requirements of the product standard are met.
10.2 Strength of materials and parts10.2.3.3 Resistance insulating Materials for outstanding Warmth
The requirements of the product standard are met.
10.2 Strength of materials and parts10.2.4 Resistance to UV
The requirements of the product standard are met.
10.2 Strength of materials and parts10.2.5 Elevation
Without object to the fact that the entire apparatus must be evaluated.
10.2 Strength of materials and parts10.2.6 shock Test
Without object to the fact that the entire apparatus must be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
The requirements of the product standard are met.
10.3 Degree of protection of the envelope
Without object to the fact that the entire apparatus must be evaluated.
10.4 isolation Distances and lines of flight
The requirements of the product standard are met.
10.5 Protection against electric shock
Without object to the fact that the entire apparatus must be evaluated.
10.6 Mounting hardware
Without object to the fact that the entire apparatus must be evaluated.
10.7 electrical Circuits and connections internal
Under the responsibility of the tableautier.
10.8 Connections for the conductors passed from the outside
Under the responsibility of the tableautier.
10.9 Properties of isolation10.9.2 withstand Voltage at industrial frequency
Under the responsibility of the tableautier.
10.9 Properties of isolation10.9.3 there Voltage shock
Under the responsibility of the tableautier.
10.9 Properties of isolation10.9.4 Test envelope insulation
Under the responsibility of the tableautier.
10.10 Warm-up
The calculation of the warm-up is under the responsibility of the tableautier. Eaton provides the data of the dissipated power of the devices.
10.11 resistance to short-circuits
Under the responsibility of the tableautier. The specifications of the devices must be observed.
10.12 electromagnetic Compatibility
Under the responsibility of the tableautier. The specifications of the devices must be observed.
10.13 mechanical Operation
At the level of the device, the required conditions are met, to the extent the instructions of the installation manual (IT) are taken into account.
,

Technical data ETIM 7.0

Switches low-voltage (EG000017) / Switch (EC001105)
Electricity, Electronics, Automation and Control / Engineering of low voltage switch / Disconnect switch, switch, switch / Switch ([email protected] [AKF062013])
model
switch
number of poles
Two
with position 0
yes
with automatic return to position 0
not
continuous current rating (Ui)
Twenty
current rated operation AC-3, 400 V
11.5 A
operating power nominal, AC-3, 400 V
4 kW
protection class (IP), front side
IP30
degree of protection (NEMA), front
other
number of auxiliary contacts opening
Zero
number of auxiliary contacts to close
Zero
number of auxiliary contacts to the two directions
Zero
suitable for mounting to the floor
yes
suited to a front mount
not
adapted to a mount distributor
yes
suitable for mounting to intermediate
not
complete device in a housing
not
housing material/body
plastic
finishing of the actuator
lever / lever
type of connection of the main circuit
screw terminal
,

Approvals

Product Standards
UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
UL File No.
E36332
UL Category Control No.
NLRV
CSA File No.
Twelve thousand five hundred twenty eight
CSA Class No.
3211-05
North America Certification
UL listed, CSA certified
Suitable for
Branch circuits, suitable as motor disconnect
Degree of Protection
IEC: IP30; UL/CSA Type: –
,

Congestion

]

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE EATON EN.pdf 51 Mbytes
SPC-S-20/335/3 248178 248178.pdf 156 Kbytes   SPC-S-20/335/3  248178 248178.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.