SPB-12/280/4 285082 SPET2-280/4 EATON ELECTRIC Surge arrester complete, 4-pole, 280VAC, 4x10kA View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SPB-12/280/4 285082 SPET2-280/4 EATON ELECTRIC Surge arrester complete, 4-pole, 280VAC, 4x10kA

SPB-12/280/4

285082

SPET2-280/4

EATON-MOELLER

Power Distribution Components IEC Miniature circuit breaker

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Surge arrester complete, 4-pole, 280VAC, 4x10kA
Alternate Catalog No.
SPET2-280/4
For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, can be bussed with all Xtra Combinations switchgear, use in accordance with IEC 60364-5-53 clause 534
[

Delivery program

Products
Surge arresters
Application field
Residential buildings
Utility buildings
Open areas
,

Technical data ETIM 7.0

Earthing, lightning and surge protection (EG000021) / Surge protection device for power supply systems (EC000941)
Electric engineering, automation, process control engineering / Protection installation, device (electric) / Surge protection device (inner lightning protection) / Surge protection device for power supply systems ([email protected] [ACN278011])
System configuration DC
No
System configuration IT
No
System configuration TN
No
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
No
System configuration TT
No
System configuration other
Yes
Number of conductors (without earthing)
4
Nominal discharge surge current (8/20)
10 kA
Nominal voltage AC
280 V
Nominal voltage DC
0 V
Short-circuit breaking capacity (Isccr)
0 kA
Max. continuous voltage AC
280 V
Max. discharge surge current (8/20)
20 kA
Max. continuous voltage DC
0 V
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
4 modular spacing
Max. PV-voltage
0 V
Voltage protection level
1.2 kV
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
0 mm²
Voltage protection level L-N
0 kV
Voltage protection level N-PE
0 kV
With remote signalling contact
No
Integrated backup fuse
No
Signalling at the device
Optic
Category type 2
Yes
Degree of protection (IP)
IP20
]

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.