NHI12-PKZ0 072895 XTPAXSA12 EATON ELECTRIC Standard auxiliary contact, 1N/O+2N/C, screw connection View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NHI12-PKZ0 072895 XTPAXSA12 EATON ELECTRIC Standard auxiliary contact, 1N/O+2N/C, screw connection

NHI12-PKZ0

072895

XTPAXSA12

EATON-MOELLER

5

Standard auxiliary contact, 1N/O+2N/C, screw connection

Standard auxiliary contact NHI, 1 N/O, 2 N/C, Side mounting, Screw connection

More details


Low-voltage industrial components > Auxiliary contact block

Motor-protective circuit-breakers PKZ (Accessories)

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Quantity Price
5+$17.02
10+$15.16
20+$13.75
25+$13.42
35+$13.05
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Standard auxiliary contact NHI, 1 N/O, 2 N/C, Side mounting, Screw connection
Standard auxiliary contact, Contacts N/O = Normally open: 1 N/O, Contacts N/C = Normally closed: 2 NC, For use with: PKZM01, PKZM0, PKZM4, PKZM0-T, PKM0, PKE

General specifications
Product name
Eaton Moeller® series NHI Accessory Standard auxiliary contact
Part no.
NHI12-PKZ0
EAN
4015080728955
Product Length/Depth
68 millimetre
Product height
90 millimetre
Product width
15 millimetre
Product weight
0.038 kilogram
Certifications
CSA
CSA File No.: 165628
UL Category Control No.: NLRV
UL File No.: E36332
CSA Class No.: 3211-05
CE
IEC/EN 60947-4-1
UL
CSA-C22.2 No. 14
UL 508
Product Tradename
NHI
Product Type
Accessory
Product Sub Type
Standard auxiliary contact
Catalog Notes
Can be retrofitted on the right side of motor-protective circuit-breakers
Features & Functions
Electric connection type
Screw connection
Features
Interlocked opposing contacts
General information
Lifespan, electrical
50,000 Operations
Model
Top mounting
Mounting method
Side mounting
Overvoltage category
III
Pollution degree
3
Product category
Accessories
Rated impulse withstand voltage (Uimp)
6000 V AC
Used with
Motor protective circuit-breaker
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Terminal capacities
Terminal capacity (solid/flexible with ferrule)
0.75 - 1.5 mm²
Terminal capacity (solid/stranded AWG)
18 - 14, Screw terminals
Electrical rating
Rated operational current (Ie)
1 A at AC-15, 440 V 500 V
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
3.5 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
2 A
Rated operational current (Ie) at DC-13, 110 V
0.5 A
Rated operational current (Ie) at DC-13, 220 V, 230 V
0.25 A
Rated operational current (Ie) at DC-13, 24 V
2 A
Rated operational current (Ie) at DC-13, 60 V
1 A
Rated operational voltage (Ue) at AC - max
500 V
Rated operational voltage (Ue) at DC - max
250 V
Safe isolation
440 V, Between auxiliary contacts and main contacts, According to EN 61140
Short-circuit protection rating without welding
10 A gG/gL, Fuse, Auxiliary contacts
Switching capacity
Switching capacity (auxiliary contacts, general use)
1 A, 250 V DC, (UL/CSA)
5 A, 600 V AC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)
Q300, DC operated (UL/CSA)
A600, AC operated (UL/CSA)
Communication
Connection type
Screw connection
Contacts
Control circuit reliability
< 2 λ, < 1 failure at 100,000,000 Operations (at Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
2
Number of contacts (normally open contacts)
1
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.04 W
Rated operational current for specified heat dissipation (In)
3.5 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss13-27-37-13-02 [AKN342018])
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Number of contacts as normally closed contact
2
Number of fault-signal switches
0
Rated operation current Ie at AC-15, 230 V
3.5 A
Type of electric connection
Screw connection
Model
Clip-on
Mounting method
Side mounting
Lamp holder
None

Datasheet - PDF

Reviews (1)

  • Acrebind Ltd
    Customer rating:
  • Page:1
    Add Review
    hide form
    Rating:
    Name:
    Email:
    Subject:
    Text:
      Captcha
      Add review

    All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.