SWD4-3LF8-24-2S 116027 EATON MOELLER Flat cable, SmartWire-DT, 3m, 8-Pole, prefabricated with 2 blade termin.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SWD4-3LF8-24-2S 116027 EATON MOELLER Flat cable, SmartWire-DT, 3m, 8-Pole, prefabricated with 2 blade termin..

SWD4-3LF8-24-2S

116027

EATON - MOELLER

Available

Ship on today

Flat cable, SmartWire-DT, 3m, 8-Pole, prefabricated with 2 blade terminals SWD4-8MF2

More details


Programmable Relays

SmartWire-DT

SmartWire-DT - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$10.08
19+$8.48
38+$8.27
57+$8.16
76+$8.09
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  SmartWire-DT accessories
Basic function
  SWD ribbon cable
Function
  For connecting the SmartWire-DT modules within the control panel
Description
  8 pole
prefabricated with two blade terminals SWD4-8MF2
Length
 m3
Note regarding length
  1 off
Connection to SmartWire-DT
  yes
For use with
  EU5C-SWD…
EU5E-SWD…
M22-SWD…
DIL-SWD…
Protection type (IEC/EN 60529, EN50178, VBG 4)
  IP20
Technical data
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
  IP20
Climatic environmental conditions
Condensation
  Take appropriate measures to prevent condensation
Relative humidity, non-condensing (IEC/EN 60068-2-30)
 %5 - 95
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA0
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Meets the product standard's requirements.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Cables and wires unpreassembled (EG000001) / Data cable (EC000830)
Electric engineering, automation, process control engineering / Cable, wire / Communication cable / Data cable ([email protected] [AKE197011])
Conductor material
  Cu, tinned
Diameter conductor
 mm1.35
Nominal cross section conductor
 mm²0.23
AWG-size
  24
Conductor category
  Class 2 = stranded
Number of cores
  8
Stranding element
  No
Core insulation
  PVC
Core identification
  Colour
Screen over stranding element
  None
Screen over stranding
  None
Material outer sheath
  PVC
Colour outer sheath
  Green
Halogen free (acc. EN 60754-1/2)
  Yes
Flame retardant
  In accordance with EN 60332-1-2
Low smoke (acc. EN 61034-2)
  No
Outer diameter approx.
 mm17.5
Permitted cable outer temperature, in movement
 °C-10 - 105
Permitted cable outer temperature, fixed
 °C-30 - 105
Category
  -
NVP value
 %66.7
Approvals
UL File No.  E29184
UL Category Control No.  NKCR
CSA File No.  2324643
CSA Class No.  3211-07
North America Certification  UL listed, CSA certified
Specially designed for North America  No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or