FI-80/4/03-S/B 281024 EATON MOELLER Residual current circuit-breaker, 80A, 4p, 3A, B-Char View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FI-80/4/03-S/B 281024 EATON MOELLER Residual current circuit-breaker, 80A, 4p, 3A, B-Char

FI-80/4/03-S/B

281024

EATON - MOELLER

Available

Ship on today

Residual current circuit-breaker, 80A, 4p, 3A, B-Char

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Commercial Protective Devices - EATON - MOELLER

Residual Current Devices PFIM-B and PFGM - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Basic function
  Residual current circuit breakers
Pole
  4 pole
Rated current
InA80
Rated short-circuit strength
IcnkA10
Rated fault current
IΔNA0.3
Type
  Type S/B
Tripping
 Aselective switch off
Product range
  FI
Sensitivity
  All current sensitive
Impulse withstand current
  surge-proof 5 kA
Technical data
Electrical
Standards
  IEC/EN 61008
Tripping
 Aselective switch off
Rated operating voltage
UeV AC230/400
Limit values of the operating voltage
 V AC184 … 440
Rated frequency
fHz50
Rated fault currents
IΔnmA30, 100, 300, 500
Rated non-tripping current
IΔno 0.5 x I ∆n
Rated fault switching capacity
   
Rated fault switching capacity
IΔmAIn = 40 A: 500
In = 63 A: 630
In = 80 A: 800
In = 100 A: 1000
In = 125 A: 1250
Sensitivity
  Pulsed current and AC/DC
Rated switching capacity
IcnkA10
Rated current
IeA80
Rated impulse withstand voltage
UimpkV4
 
   
Maximum max. as short-circuit protective device
 A gLIn < 80 A: 100
In= 80 A: 125
In= 125 A: 125
Lifespan
 S 
Electrical
 Operations> 2000
Mechanical
 Operations> 5000
Mechanical
Standard front dimension
 mm45
Enclosure height
 mm85
Terminal protection
  Protection against electric shock to IEC 536
Mounting width
 mm70 (4 space unit)
Mounting
  Top-hat rail IEC/EN 60715
Degree of protection
   
Integrated
  IP40
Terminals top and bottom
  Twin-purpose terminals
Terminal capacities
 mm2 
Solid
 mm21.5 - 50; 2 x (1.5 - 16)
Stranded
 mm21.5 - 50; 2 x (1.5 - 16)
flexible
 mm21.5 - 50; 2 x (1.5 - 16)
Thickness of busbar material
 mm0.8 … 2
Admissible ambient temperature range
 °C-25 … +40
Climatic proofing
  IEC/EN 61008
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA80
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW11.4
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C55
 
  Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °C
Technical data ETIM 6.0(Show features)(Hide features)
Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906011])
Number of poles
  4
Nominal rated voltage
 V400
Nominal rated current
 A80
Rated fault current
 A0.3
Mounting method
  DIN rail
Leakage current type
  B
Selective protection
  Yes
Short-circuit breaking capacity (Icw)
 kA10
Surge current capacity
 kA5
Frequency
  50 Hz
Additional equipment possible
  Yes
Degree of protection (IP)
  IP20
Construction size (in accordance with DIN 43880)
  1
Width in number of modular spacings
  4
Built-in depth
 mm69.5
Short-time delayed tripping
  Yes
Dimensions
AWA1290-1756 Residual-current-circuit-breaker
 
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or