DILM12-XSPR500 281201 EATON MOELLER RC suppressor circuit, 240-500VAC, for DILA, DILM7-13 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM12-XSPR500 281201 EATON MOELLER RC suppressor circuit, 240-500VAC, for DILA, DILM7-13

DILM12-XSPR500

281201

EATON - MOELLER

Available

Ship on today

RC suppressor circuit, 240-500VAC, for DILA, DILM7-13

More details


Contactor Relays

DIL Contactors - EATON - MOELLER

DIL Contactors (Accessories)- EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$7.29
19+$6.14
37+$6.00
55+$5.92
73+$5.87
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Accessories
Accessories
  Suppressor circuit
Voltage
UsV240 - 500 AC
For use with
  DILM7 - DILM15
DILMP20
DILA
Contact sequence
  >
Instructions
  For AC operation contactors 50 - 60 Hz.
With DC operated contactors and with DILM115 and DILM150 the suppressor is integrated.
Note drop-out delay
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA0
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C60
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Surge protection module (EC000683)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Component for protective circuit ([email protected] [AKF019010])
Function
  RC-element
Rated control supply voltage Us at AC 50HZ
 V240 - 500
Rated control supply voltage Us at AC 60HZ
 V240 - 500
Rated control supply voltage Us at DC
 V0 - 0
Voltage type for actuating
  AC
With LED indication
  No
Approvals
Product Standards  IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.  E29096
UL Category Control No.  NLDX
CSA File No.  227038
CSA Class No.  3211-07
North America Certification  UL listed, CSA certified
Specially designed for North America  No
Dimensions
>
CAD data
>Product-specific CAD data
>3D Preview

Datasheet - PDF

Title:Language:Size:Type:
Datasheet 1: 281201 - DILM12-XSPR500English165 KbytesDatasheet 1: 281201 - DILM12-XSPR500
Complete catalogue 1: 281201 - DILM12-XSPR500English22 MbytesDatasheet 1: 281201 - DILM12-XSPR500

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or