RASP-304AI1S0-C320S1 169806 EATON MOELLER RASP-304AI1S0-C320S1 Rapid Link speed controller up to 3.3 A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RASP-304AI1S0-C320S1 169806 EATON MOELLER RASP-304AI1S0-C320S1 Rapid Link speed controller up to 3.3 A

RASP-304AI1S0-C320S1

169806

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

RASP-304AI1S0-C320S1 Rapid Link speed controller up to 3.3 A

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Speed controller
Description
  integrated PTC thermistor monitoring and Thermoclick with safe isolation
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Connection of supply voltage via adapter cable on round or flexible busbar junction
Diagnostics and reset on device and via AS-Interface
with AUTO - OFF/RESET - HAND key switches
3 fixed speeds and 1 potentiometer speed
can be switched over from U/f to (vector) speed control
Two sensor inputs through M12 sockets with Y-connector (optional) for creep speed
with selector switch REV - OFF - FWD
selectable: with quick stop on failure of the external 24 V
Repair switch
  without manual override switch
Fan
  without fan
Braking resistance
  without braking resistance
Rated operational voltage
Ue 400 V AC, 3-phase
Output voltage with Ve
U2 400 V AC, 3-phase
Mains voltage (50/60Hz)
ULNV380 (-10%) - 480 (+10%)
At 150% overload
IeA3.3
Control voltage external brake (50/60 Hz)
 V AC400
Mains voltage (50/60Hz)
ULNV380 (-10%) - 480 (+10%)
assigned motor rating P
   
Note
  at 400 V, 50 Hz
150 % Overload
PkW1.1
Note
  at 440 - 480 V, 60 Hz
150 % Overload
PHP1.5
Note
  for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
AS-Interface profile cable
  S-7.4 for 31 modules
Instructions for actuation of motors with mechanical brake
Technical data
General
Standards
  EN 61800-5-1
EN 61800-3
Directive 2002/95/EG (RoHS)
CE approval
Climatic proofing
ρw%< 95%, non-condensing
IEC/EN 50178
Ambient temperature
   
Storage
ϑ°C-30 - +70
Overvoltage category
  III
Rated impulse withstand voltage
UimpkV2
Radio interference level
   
Environment (EMC)
  2. Environment, Class C3
maximum motor cable length
Im5
Mechanical shock resistance
 g1000 shocks per shaft, semi-sinusoidal 15 g/11 ms
IEC/EN 60068-2-27
Vibration
  Oscillation frequency: 10 - 150 Hz
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
Mounting position
  Vertical
Altitude
 m0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m
Degree of Protection
  IP65
IEC/EN 60529
Main circuit
Supply
   
Rated operational voltage
Ue 400 V AC, 3-phase
Mains voltage (50/60Hz)
ULNV380 (-10%) - 480 (+10%)
Input current (150% overload)
ILNA4
System configuration
  AC voltage
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Supply frequency
fLNHz50/60
Frequency range
fLNHz47 - 66 Hz (± 0%)
Mains switch-on frequency
  Maximum of one time every 60 seconds
Mains current distortion
THD%> 120
Rated conditional short-circuit current
IqkA< 5
Short-circuit protection for output circuits, external
  Type 1 coordination via the power bus' feeder unit
Power section
   
Function
  Frequency inverter with internal DC link and IGBT inverter
On-delay
tONms30 - 50
Off-delay
tOFFms15 - 35
Overload current (150% overload)
ILA5
Note regarding overload current
  at 40 °C
Note about max. starting current
  for 2 seconds
at 40 °C
Output voltage with Ve
U2 400 V AC, 3-phase
Output Frequency
f2Hz0 - 50/60 (max. 320)
Switching frequency
fPWMkHz6
adjustable 1.5 - 16
Operation Mode
  linear, parameterizable
Frequency resolution (setpoint value)
ΔfHz0.01
Rated operational current
   
At 150% overload
IeA3.3
Note
  Rated operational current at an operating frequency of 6 kHz and an ambient air temperature of +40 °C
Motor current limit
I A0.66 - 6.6
adjustable
Efficiency
η%0.95
Maximum leakage current to ground (PE) without motor
IPEmA3.5
Fan
  internal, temperature controlled
optional RASP-FAN-S1 on heat sink, temperature-controlled
Fitted with
  without manual override switch
without fan
without braking resistance
Motor feeder
   
Note
  for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
Note
  at 400 V, 50 Hz
150 % Overload
PkW1.1
Note
  at 440 - 480 V, 60 Hz
150 % Overload
PHP1.5
Actuator for external motor brake
   
Breaking voltage
UV400 V AC -15% / +10%
Braking current
I A≤ 0.6 A
(max. 6 A for 120 ms)
Braking function
   
DC braking
%I/Ieborder=1>>IL03406020Z Rapid Link: Speed Control Unit
MN03406003Z Rapid Link 4.0
 
>border=1>>MN03406003Z Rapid Link 4.0 - Deutsch
 
>border=1>>MN03406003Z Rapid Link 4.0 - English
>border=1>>CA04020001Z-DE Sortimentskatalog: Antriebstechnik effizient gestalten, Motoren starten und steuern

Datasheet - PDF

Title:Language:Size:Type:
EATON MOELLER-169806-RASP-304AI1S0-C320S1English183 KbytesEATON MOELLER-169806-RASP-304AI1S0-C320S1

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or