DILK20-11(190V50HZ,220V60HZ) 294008 EATON MOELLER Contactor for 3ph three-phase capacitors, 20kVAR View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILK20-11(190V50HZ,220V60HZ) 294008 EATON MOELLER Contactor for 3ph three-phase capacitors, 20kVAR

DILK20-11(190V50HZ,220V60HZ)

294008

EATON - MOELLER

Available

Ship on today

Contactor for 3ph three-phase capacitors, 20kVAR

More details


Contactor Relays

DIL Contactors - EATON - MOELLER

DILK Contactors - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$51.76
3+$49.39
5+$48.53
7+$48.03
10+$47.65
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  DILK Contactors for capacitors
Application
  Contactors for power factor correction
Three-phase capacitors 50 - 60 Hz
   
Open
   
230 V
 kVAr11
400 V
 kVAr20
525 V
 kVAr25
690 V
 kVAr33.3
Contact sequence
  
General
Standards
  IEC/EN 60947
Ambient temperature
   
Open
 °C-25 - +60
Enclosed
 °C- 25 - 40
Mounting position
  
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA29
Heat dissipation per pole, current-dependent
PvidW1.8
Equipment heat dissipation, current-dependent
PvidW5.4
Static heat dissipation, non-current-dependent
PvsW2.1
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C60
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Capacitor contactor (EC001079)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Capacitor contactor ([email protected] [AGZ569012])
Rated control supply voltage Us at AC 50HZ
 V190 - 190
Rated control supply voltage Us at AC 60HZ
 V220 - 220
Rated control supply voltage Us at DC
 V0 - 0
Voltage type for actuating
  AC
Number of auxiliary contacts as normally open contact
  1
Number of auxiliary contacts as normally closed contact
  1
Type of electrical connection of main circuit
  Screw connection
Number of main contacts as normally open contact
  3
Number of normally closed contacts as main contact
  0
Rated blind power at 400 V, 50 Hz
 kvar20
Approvals
Product Standards  IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.  E29096
UL Category Control No.  NLDX
CSA File No.  012528
CSA Class No.  3211-04
North America Certification  UL listed, CSA certified
Specially designed for North America  No
Dimensions
IL03407038Z (AWA2100-2272) Contactor for capacitors
 
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or