KST34-150 074520 EATON MOELLER Panel enclosure, with gland plate and cable glands, HxWxD 375x250x175mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

KST34-150 074520 EATON MOELLER Panel enclosure, with gland plate and cable glands, HxWxD 375x250x175mm

KST34-150

074520

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Panel enclosure, with gland plate and cable glands, HxWxD=375x250x175mm

More details


Control Cabinets Switch Boxes Distribution Enclosures

Enclosures- EATON - MOELLER

CI insulated enclosures - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$110.41
2+$107.36
4+$104.89
5+$104.19
7+$103.58
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Ci insulated enclosures
Basic function
  Basic enclosures
Product function
  Panel enclosure with gland plates fitted
Single unit/Complete unit
  Stand-alone device
Degree of Protection
  IP65 (from below)
Description
  Sealable cover fasteners
Sides closed, but with full area knockout
Open top
Fitting of cable supports in the distribution board with wedge-lock fastener
Gland plate can be split, cables can be inserted from the front
Model base
  Plain
Type cover
  Transparent
Width
 mm250
Height
 mm375
Depth
 mm175
Mounting depth with mounting plate
 mm150
Mounting depth for mounting rail 7.5 mm height
 mm142.5
Mounting depth for mounting rail 15 mm height
 mm135
Dimensions
 mm
General
Ambient temperature
 °C-40 - +80
Ambient temperature
   
Mean value over 24 hours
 °C35
Limit values
 °C 
Ambient temperature limit value min.
 °C-5
Ambient air temperature, limit values max.
 °C40
Degree of Protection
  IP65 (from below)
Protection type
  IP65 (Enclosure)
IP65 (KST cable entries from below)
IP64 (KST cable entries from above)
IP00 (Cable entry open)
Components
  Switchgear assembly components are type-tested. They are available individually for the self-assembly of switchgear installations, distribution boards and control panels.
Devices that can be fitted
  The reference values indicated in the table apply to the basic elements of the distribution board. As far as devices, terminals etc. fitted into the enclosures are concerned, their own specific technical data and rated values apply.
Standards
   
TTA - Type Tested Assemblies
  IEC/EN 60439-1, VDE 0660 Part 500
Low-voltage fuses
  IEC/EN 60269, VDE 0636
Type test
  VDE 0660 Part 500, IEC/EN 60439-1
Creepage and clearance distances
  III/3 to IEC/EN 60439-1
Flammability characteristics - Glow rod test
  VDE 0304 Part 3 level IIb, level IIb to IEC 60707
Regulation for the fire resistance tests of electrical products, their modules and components, glow wire test
  VDE 0471 Part 2
Operating and ambient conditions to VDE 0660 Part 500
   
Ambient temperature
   
Mean value over 24 hours
 °C35
Limit values
 °C-5…40
Indoor installation
   
Relative humidity
  90 % (at 20°C)
50% (at 40°C)
Altitude
 mMax. 2000
Protection type
  IP65 (Enclosure)
IP65 (KST cable entries from below)
IP64 (KST cable entries from above)
IP00 (Cable entry open)
Mounting grid
 mm25 (DIN 43660)
Colour
   
Base
  RAL 7032, pebble grey
Housing body
  Transparent, colourless or RAL 7032, pebble grey
 
  CI...-NA: Transparent cover, opaque
Surface finish
  Galvanized
Passivated
Material characteristics
Surface finish
  Galvanized
Passivated
Colour
   
Base
  RAL 7032, pebble grey
Housing body
  Transparent, colourless or RAL 7032, pebble grey
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees, calculated as per IEC 60890
   
Individual enclosure for wall mounting
PVCO20
Starting enclosure for wall mounting
PVCO19
Middle enclosure for wall mounting
PVCO17
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees, calculated as per IEC 60890
   
Individual enclosure for wall mounting
PVCO41
Starting enclosure for wall mounting
PVCO38
Middle enclosure for wall mounting
PVCO34
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Lower part: 960 °C / cover: 850 °C; meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Not relevant to indoor installations.
10.2.5 Lifting
  10 kg per enclosure with support frame and lifting aid met; assembled and secured as per the latest applicable instruction leaflet.
10.2.6 Mechanical impact
  IK10
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  IP65
10.4 Clearances and creepage distances
  Is the panel builder's responsibility.
10.5 Protection against electric shock
  Protection class 2, therefore not applicable.
10.6 Incorporation of switching devices and components
  Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Ui = 1000 V AC
10.9.3 Impulse withstand voltage
  8 kV
10.9.4 Testing of enclosures made of insulating material
  Meets the product standard's requirements.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility.
10.13 Mechanical function
  Meets the product standard's requirements.
Dimensions
AWA3200-0572 Gland plates
 
>>

Datasheet - PDF

Title:Language:Size:Type:
Datasheet 1: 074520 - KST34-150English230 KbytesDatasheet 1: 074520 - KST34-150
Datasheet 2: 074520 - KST34-150English86 KbytesDatasheet 1: 074520 - KST34-150
Complete catalogue 1: 074520 - KST34-150English18 MbytesDatasheet 1: 074520 - KST34-150

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or