XC-CPU101-C64K-8DI-6DO 262152 EATON MOELLER Modular PLC, 24 V DC, 8DI, 6DO, RS232, CAN, 64kB View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

XC-CPU101-C64K-8DI-6DO 262152 EATON MOELLER Modular PLC, 24 V DC, 8DI, 6DO, RS232, CAN, 64kB

XC-CPU101-C64K-8DI-6DO

262152

EATON - MOELLER

Available

Ship on today

Modular PLC, 24 V DC, 8DI, 6DO, RS232, CAN, 64kB

More details


Programmable Logic Controllers Plcs

XC Modular PLC - EATON - MOELLER

XC Modular PLC - CPU's - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$445.40
2+$435.85
3+$433.97
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Digital input count
  Digital: 8; of which usable as interrupt: 4
Quantity of outputs
  Transistor: 6
Built-in interfaces
  CANopen®
RS232
Instructions
  expandable with → expansions XI/OC
Only on connection with →XI/OC rack
User memory
  64 Kbyte
Cycle time for 1 k of instructions (Bit, Byte)
 ms0.5
Memory
   
Application/marker/retain data
 KByte64 KB/4 KB/4 KB
Integrated Web server
  no
Information about equipment supplied
  The following accessory equipment is required: terminal clamps, module rack, battery
Technical data
General
Standards
  IEC/EN 61131-2
EN 50178
Ambient temperature
 °C0 - +55
Storage
ϑ°C-25 - +70
Mounting position
  Horizontal
Relative humidity, non-condensing (IEC/EN 60068-2-30)
 %10 - 95
Air pressure (operation)
 hPa795 - 1080
Vibration resistance
  10 - 57 Hz ±0.075 mm
57 - 150 Hz ±1.0 g
Mechanical shock resistance
 g15
Shock duration 11 ms
Overvoltage category/pollution degree
  II/2
Degree of Protection
  IP20
Rated insulation voltage
UiV500
Emitted interference
  EN 50081-2, Class A
Interference immunity
  EN 50081-2
Battery (service life)
  normally 5 years
Weight
 kg0.23
Terminations
  Plug-in terminal block
Terminal capacities
 mm2 
Screw terminals
   
Flexible with ferrule
 mm20.5 - 1.5
Solid
 mm20.5 - 2.5
Spring-loaded terminals
   
flexible
 mm20.34 - 1.0
Solid
 mm20.14 - 1.0
Power supply
Duration of mains dip
 ms10
Repetition rate
 s1
Input voltage
 V DC24
Admissible range
 V DC20.4 - 28.8
Input rating
 Wmax. 26
Residual ripple
 %
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA0
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW6
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C0
Operating ambient temperature max.
 °C55
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Meets the product standard's requirements.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Approvals
Product Standards  IEC: see Technical Data; UL508; CSA-C22.2 No. 0-M; CSA-C22.2 No. 142-M; CE marking
UL File No.  E135462
UL Category Control No.  NRAQ
CSA File No.  012528
CSA Class No.  2252-01
North America Certification  UL listed, CSA certified
Specially designed for North America  No
Current Limiting Circuit-Breaker  No
Degree of Protection  IEC: IP20, UL/CSA Type: -
Dimensions
MN05003004Z Manual modular PLC XC-CPU101…(-XV)
 
>
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or