EMR5-N80-1-B 134232 EATON ELECTRIC Liquid level monitoring relay, 1W, 220-240V50/60Hz, 5-100kOhm View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EMR5-N80-1-B 134232 EATON ELECTRIC Liquid level monitoring relay, 1W, 220-240V50/60Hz, 5-100kOhm

EMR5-N80-1-B

134232

EATON-MOELLER

Liquid level monitoring relay, 1W, 220-240V50/60Hz, 5-100kOhm

More details


Relay timers (KETR, KEMR, KESR)

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: EMR6-N100-N-1 184758

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Liquid level monitoring relay, 1W, 220-240V50/60Hz, 5-100kOhm
Eaton Catalog No.
EMR5-N80-1-B
EL-Nummer (Norway)
4110391
Liquid level monitoring relay EMR5N… according to IEC/EN 60255-6, 22.5 mm wide, 220-240VAC, for monitoring the fill level or ratio of mixtures of conductive liquids, 5kOhm-100kOhm, 1 changeover contacts
[

Delivery program

This item will continue to be available for a limited time only and is being replaced by the following item: 184758, EMR6-N100-N-1
Product range
EMR Measuring and monitoring relays
Basic function
Level monitoring relays
Monitoring of
Fill level of conductive liquids
Mixture ratio of conductive liquids
adjustable sensitivity range
5 - 100 kΩ
Contact sequence
Supply voltage
220 - 240 V AC, 50/60 Hz
Width
22.5 mm
,

Technical data

Technical data in sheet catalogue
Other technical data (sheet catalogue)
Level monitoring relays
,

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
2 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
,

Technical data ETIM 7.0

Relays (EG000019) / (Fill) level monitoring relay (EC001447)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Monitoring equipment (low-voltage switch technology) / Level monitoring relay ([email protected] [AKF107014])
Type of electric connection
Screw connection
Rated control supply voltage Us at AC 50HZ
220 - 240 V
Rated control supply voltage Us at AC 60HZ
220 - 240 V
Rated control supply voltage Us at DC
0 - 0 V
Voltage type for actuating
AC
With detachable clamps
No
Number of inputs for electrodes
0
Min. adjustable operate delay time
0 s
Max. permitted operate delay time
0 s
Min. adjustable off-delay time
0 s
Max. permitted off-delay time
0 s
Response value sensitivity adjustable
Yes
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
1
Physical measurement principle
Conductive
Cascadable
No
Width
22.5 mm
Height
78 mm
Depth
100 mm
,

Approvals

Product Standards
IEC 255-6; UL 508; CSA-22.2 No. 14-05; CE marking
UL File No.
E29184
UL Category Control No.
NKCR, NKCR7
CSA File No.
UL report valid
CSA Class No.
3211-03
North America Certification
UL listed, certified by UL for use in Canada
Degree of Protection
IEC: IP20, UL/CSA Type: -
,

Characteristics

Characteristic curve
AC load (resistive)
Characteristic curve
DC load (resistive)
Characteristic curve
Derating factor F with inductive AC load
Characteristic curve
Contact life
S operations
220 V 50 Hz AC-1
360 operations/h
,

Dimensions

]

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.