UTI0,5-115 206926 UTI0.5-115 EATON ELECTRIC Its own control transformer, 1p, 500VA, prim.208-600V/ seco.2x11.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

UTI0,5-115 206926 UTI0.5-115 EATON ELECTRIC Its own control transformer, 1p, 500VA, prim.208-600V/ seco.2x11..

UTI0,5-115

206926

UTI0.5-115

EATON-MOELLER

Its own control transformer, 1p, 500VA, prim.208-600V/ seco.2x115V

UTI0,5-115

Eaton Moeller® series UTI Control transformer, 0.5 kVA, Rated input voltage 208 – 600 V, Rated output voltage 2 x 115 V

More details


Low-voltage industrial components > One-phase control transformer

Transformers

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $255.84
Unit price: $255.84

Quantity Price
1+$255.84
2+$228.49
3+$222.14
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



General specifications

Product Name
Eaton Moeller® series UTI Control transformer
Catalog Number
206926
Model Code
UTI0,5-115
EAN
4015082069261
Product Length/Depth
120 mm
Product Height
124 mm
Product Width
121 mm
Product Weight
6.8 kg
Certifications
CE
UL Recognized
CSA-C22.2 No. 66.1-06
UL 5085-2
UL5085-1
UL Category Control No.: XPTQ2, XPTQ8
IEC/EN 60204-1, ÖVE-EN 13
IEC/EN 61558-2-2
CSA-C22.2 No. 66
VDE 0570 Part 2-2/2-6 (safety transformer)
UL report applies to both US and Canada
Certified by UL for use in Canada
UL 506
IEC/EN 61558-2-2/2-4/2-6
VDE 0113, VDE 0100 Part 410
CSA-C22.2 No. 66.2-06
UL File No.: E167225
VDE 0570 Part 2-4 (isolating transformer)
VDE 0550
Catalog Notes
Electrical characteristics: all details for no-load loss, short-circuit loss (copper losses), short-circuit voltage and efficiency values relate to a temperature of 20 °C

Product specifications

Features
Separate windings
Fully Vacuum-impregnated
Reinforced insulation
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-25 °C
Apparent power
500 VA
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
No-load losses
26 W
Primary voltage 1 - max
600 V
Primary voltage 1 - min
208 V
Primary voltage 10 - max
0 V
Primary voltage 10 - min
0 V
Primary voltage 2 - max
0 V
Primary voltage 2 - min
0 V
Primary voltage 3 - max
0 V
Primary voltage 3 - min
0 V
Primary voltage 4 - max
0 V
Primary voltage 4 - min
0 V
Primary voltage 5 - max
0 V
Primary voltage 5 - min
0 V
Primary voltage 6 - max
0 V
Built as
Safety transformer
Isolating transformer
Conductor material
Copper
Degree of protection
IP00
Connection type
Terminations
Duty factor
100 %
Insulation material type (IEC 85)
B
Efficiency
91.8 %
Relative short-circuit voltage
3.5 %
Suitable for
Branch circuits, (UL/CSA)
Insulation class
B
Primary tapping
± 20 %
Primary voltage 6 - min
0 V
Primary voltage 7 - max
0 V
Primary voltage 7 - min
0 V
Primary voltage 8 - max
0 V
Primary voltage 8 - min
0 V
Primary voltage 9 - max
0 V
Primary voltage 9 - min
0 V
Rated frequency - max
60 Hz
Rated frequency - min
50 Hz
Rated operational current for specified heat dissipation (In)
0 A
Rated power
0.5 VA
Secondary voltage 1 - max
115 V
Secondary voltage 1 - min
115 V
Secondary voltage 10 - max
0 V
Secondary voltage 10 - min
0 V
Secondary voltage 2 - max
115 V
Secondary voltage 2 - min
115 V
Secondary voltage 3 - max
0 V
Secondary voltage 3 - min
0 V
Secondary voltage 4 - max
0 V
Product category
Single-phase UTI multi-winding transformers
Secondary voltage 4 - min
0 V
Secondary voltage 5 - max
0 V
Secondary voltage 5 - min
0 V
Secondary voltage 6 - max
0 V
Secondary voltage 6 - min
0 V
Secondary voltage 7 - max
0 V
Secondary voltage 7 - min
0 V
Secondary voltage 8 - max
0 V
Secondary voltage 8 - min
0 V
Secondary voltage 9 - max
0 V
Secondary voltage 9 - min
0 V
Short-circuit losses
23 W
Static heat dissipation, non-current-dependent Pvs
49 W
Voltage rating - max
600 V
Power consumption in standby mode
21 W

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.