NZM-XDMI612 260217 EATON MOELLER Interface, data Management, for NZM2/3/4 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM-XDMI612 260217 EATON MOELLER Interface, data Management, for NZM2/3/4

NZM-XDMI612

260217

EATON - MOELLER

Available

Ship on today

Interface, data Management, for NZM2/3/4

More details


Circuit Breakers Electrical Power

Circuit-breakers NZM and LZM (Accessories) - EATON - MOELLER

Circuit-breakers NZM and LZM (Accessories) - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Accessories
Accessories
  Diagnostics, communication
Description
  

Inclusive NZM-XDMI-CAB connection cable between NZM and DMI (length: 2 m)

  • Access to diagnostics and operational data
  • Recording of current values, motor starter function, set parameters
  • Control of the circuit-breakers with electronic trip block
  • Comprehensive remote diagnostic options and remote access via field bus in combination with a field bus connection NZM-XDMI-DPV1
  • Remote parameter definition
Standard/Approval
  IEC
Construction size
  NZM2/3/4
Notes 

Only in combination with circuit-breakers with electronic trip blocks.

Technical data
General
Dimensions (W x H x D)
 mm107.5 x 90 x 53
Modular spacing (space units)
  6 space units wide
Weight
 kg0.3
Mounting
  Top-hat rail IEC/EN 60715, 35 mm
Climatic environmental conditions
Operating ambient temperature
 °C0 to +55
Mounting position
  Vertical or horizontal
Condensation
  Take appropriate measures to prevent condensation
LCD display (clearly legible)
 °C 
LCD
  0 to +55
Storage/Transport
 °C 
Storage
ϑ°C-40 - +70
Relative humidity, non-condensing (IEC/EN 60068-2-30)
 %5 - 95
Air pressure (operation)
 hPa795 - 1080
Corrosion resistance
 cm³/m³ 
IEC/EN 60068-2-42
4 days SO2cm3/m310
IEC/EN 60068-2-43
4 days H2Scm3/m31
Ambient conditions, mechanical
Pollution degree
  2
Protection type (IEC/EN 60529, EN50178, VBG 4)
  IP20
Vibrations (IEC/EN 60068-2-6)
 Hz 
Constant amplitude 0.15 mm
 Hz10 - 57
Constant acceleration 2 g
 Hz57 - 150
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
 Impacts18
Drop to IEC/EN 60068-2-31
Drop heightmm50
Free fall, packaged (IEC/EN 60068-2-32)
 m1
Power supply
Admissible range
 V DC20.4 - 28.8
Residual ripple
 %
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
PLC's (EG000024) / Fieldbus, decentr. periphery - communication module (EC001604)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - communications module ([email protected] [BAA073010])
Supply voltage AC 50 Hz
 V0 - 0
Supply voltage AC 60 Hz
 V0 - 0
Supply voltage DC
 V24 - 24
Voltage type of supply voltage
  DC
Supporting protocol for TCP/IP
  No
Supporting protocol for PROFIBUS
  No
Supporting protocol for CAN
  No
Supporting protocol for INTERBUS
  No
Supporting protocol for ASI
  No
Supporting protocol for KNX
  No
Supporting protocol for MODBUS
  No
Supporting protocol for Data-Highway
  No
Supporting protocol for DeviceNet
  No
Supporting protocol for SUCONET
  No
Supporting protocol for LON
  No
Supporting protocol for SERCOS
  No
Supporting protocol for PROFINET IO
  No
Supporting protocol for PROFINET CBA
  No
Supporting protocol for Foundation Fieldbus
  No
Supporting protocol for EtherNet/IP
  No
Supporting protocol for AS-Interface Safety at Work
  No
Supporting protocol for DeviceNet Safety
  No
Supporting protocol for INTERBUS-Safety
  No
Supporting protocol for PROFIsafe
  No
Supporting protocol for SafetyBUS p
  No
Supporting protocol for other bus systems
  No
Radio standard Bluetooth
  No
Radio standard WLAN 802.11
  No
Radio standard GPRS
  No
Radio standard GSM
  No
Radio standard UMTS
  No
IO link master
  No
System accessory
  Yes
Degree of protection (IP)
  IP20
With potential separation
  No
Fieldbus connection over separate bus coupler possible
  No
Rail mounting possible
  Yes
Wall mounting/direct mounting
  No
Front build in possible
  Yes
Rack-assembly possible
  No
Suitable for safety functions
  No
Category according to EN 954-1
  -
SIL according to IEC 61508
  None
Performance level acc. to EN ISO 13849-1
  None
Appendant operation agent (Ex ia)
  No
Appendant operation agent (Ex ib)
  No
Explosion safety category for gas
  None
Explosion safety category for dust
  -
Width
 mm105
Height
 mm90
Depth
 mm55
Dimensions
IL01219009Z (AWA1230-2001) Data Management Interface
 
>
>
>
>
>
>
>>

Datasheet - PDF

Title:Language:Size:Type:
English198 Kbytes
English199 Kbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or