SPCT2-385/2 167604 EATON ELECTRIC Plug-in surge arresters, 2p, 385VAC, 2x20kA View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SPCT2-385/2 167604 EATON ELECTRIC Plug-in surge arresters, 2p, 385VAC, 2x20kA

SPCT2-385/2

167604

EATON-MOELLER

Plug-in surge arresters, 2p, 385VAC, 2x20kA

SPCT2-385/2

More details


Earthing, lightning and surge protection > Surge protection device for power supply systems

Modular Switchgear – Industrial

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $119.55
Unit price: $119.55

Quantity Price
1+$119.55
2+$104.85
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Plug-in surge arresters, 2p, 385VAC, 2x20kA
For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear

General specifications
Product name
Eaton Moeller series xPole - SPCT2 Surge Protection Device
Part no.
SPCT2-385/2
EAN
4015081640959
Product Length/Depth
85 millimetre
Product height
67 millimetre
Product width
35 millimetre
Product weight
0.217 kilogram
Compliances
RoHS conform
Product Tradename
xPole - SPCT2
Product Type
Surge Protection Device
Product Sub Type
None
Delivery program
Application
Open areasResidential buildingsUtility buildings
Type
Surge arrester
Technical Data - Electrical
Voltage protection level
1.8 kV
Voltage protection level (L-N)
0 kV
Voltage protection level (N-PE)
0 kV
Nominal voltage at AC
385 V
Nominal voltage at DC
0 V
Continuous voltage at AC - max
385 V
Continuous voltage at DC - max
0 V
PV-voltage - max
0 V
Nominal discharge surge current (8/20)
20 kA
Discharge surge current (8/20) - max
40 kA
Short-circuit breaking capacity (ISCCR)
0 kA
Signalling at the device
Optic
Technical Data - Mechanical
Frame
2 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Number of conductors without earthing
2
Conductor cross section (flexible, fine-strand) - min
35 mm²
Conductor cross section (flexible, fine-strand) - max
35 mm²
Conductor cross section (solid, solid-strand) - min
25 mm²
Conductor cross section (solid, solid-strand) - max
25 mm²
Degree of protection
IP20
Additional information
Features
Category type 2
System configuration type
TN
Other
TN-S

Technical data ETIM 9.0

Earthing, lightning and surge protection (EG000021) / Surge protection device for power supply systems (EC000941)
Electric engineering, automation, process control engineering / Internal and external lightning protection / Lightning protection (other) / Lightning protection (other, not specified) (ecl@ss13-27-17-90-90 [AHE465002])
System configuration DC
No
System configuration IT
No
System configuration TN
Yes
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
Yes
System configuration TT
No
System configuration other
Yes
Number of conductors (without earthing)
2
Nominal discharge surge current (8/20)
20 kA
Max. discharge surge current (8/20)
40 kA
Nominal voltage AC
385 V
Nominal voltage DC
0 V
Max. continuous voltage AC
385 V
Max. continuous voltage DC
0 V
Max. PV-voltage
0 V
Voltage protection level
1.8 kV
Voltage protection level L-N
0 kV
Voltage protection level N-PE
0 kV
Max. overcurrent protection device, parallel connection (fuse)
0 A
Max. overcurrent protection device, series connection (fuse)
125 A
Short-circuit breaking capacity (Isccr)
0 kA
Integrated short-circuit protection
No
Integrated short-circuit protection selective to fuse gG
0 A
Integrated backup fuse
No
Leakage-current free
No
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
2 modular spacing
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
With remote signalling contact
No
Signalling at the device
Optical
Category type 2
Yes
Degree of protection (IP)
IP20

Datasheet - PDF

Reviews (1)

  • bruno ricamo
    Customer rating:
  • Page:1
    Add Review
    hide form
    Rating:
    Name:
    Email:
    Subject:
    Text:
      Captcha
      Add review

    All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.