SPBT12-280/3 158330 SPBT12-280-3 EATON ELECTRIC Lightning current and surge arresters kit, TN-C kit, 3p View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SPBT12-280/3 158330 SPBT12-280-3 EATON ELECTRIC Lightning current and surge arresters kit, TN-C kit, 3p

SPBT12-280/3

158330

SPBT12-280-3

EATON-MOELLER

Lightning current and surge arresters kit, TN-C kit, 3p

SPBT12-280/3

More details


Earthing, lightning and surge protection > Combined arrester for power supply systems

Modular Switchgear – Industrial

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $254.24
Unit price: $254.24

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Lightning current and surge arresters kit, TN-C kit, 3p
For protecting consumer systems against transient overvoltages caused by direct and indirect lightning strikes and switching operations, use in accordance with IEC 60364-5-53 section 534, iI according to IEC 61643-1, SPD-type T1, T2 according to EN 61643-11, lightning protection classes III and IV as per IEC 62305, type without remote signaling

General specifications
Product name
Eaton Moeller series xPole - SPBT12 Surge Protection Device
Part no.
SPBT12-280/3
EAN
4015081548880
Product Length/Depth
86 millimetre
Product height
69 millimetre
Product width
52.5 millimetre
Product weight
0.429 kilogram
Compliances
RoHS conform
Product Tradename
xPole - SPBT12
Product Type
Surge Protection Device
Product Sub Type
None
Delivery program
Application
Open areas
Residential buildings
Utility buildings
Number of poles
Three-pole
Type
Surge arrester
Technical Data - Electrical
Voltage protection level
1.5 kV
Voltage protection level (DC+ - DC-)
0 kV
Voltage protection level (DC+/DC- - PE)
0 kV
Voltage protection level (L-N)
0 kV
Voltage protection level (L-PE)
1.5 kV
Voltage protection level (N-PE)
0 kV
Nominal voltage at AC
280 V
Nominal voltage at DC
0 V
Continuous voltage at AC - max
280 V
Continuous voltage at DC - max
0 V
PV-voltage - max
0 V
Lightning impulse current (10/350 µs)
12.5 kA
Follow current extinguishing capability
0 kA
Signalling at the device
Optic
Specific energy (W/R)
39.1 kJ/Ohm
Technical Data - Mechanical
Frame
3 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Conductor cross section (flexible, fine-strand) - max
35 mm²
Conductor cross section (solid, solid-strand) - max
25 mm²
Degree of protection
IP20
Additional information
System configuration type
Other
TN-C-S
TN-C
TN
TN-S
TT
Test class
Type 1 + 2

Technical data ETIM 9.0

Earthing, lightning and surge protection (EG000021) / Combined arrester for power supply systems (EC001457)
Electric engineering, automation, process control engineering / Internal and external lightning protection / Combined SPD for energy and information technology / Energy and MSR technology (ecl@ss13-27-17-16-01 [AHE455002])
System configuration DC
No
System configuration IT
No
System configuration TN
Yes
System configuration TN-C
Yes
System configuration TN-C-S
Yes
System configuration TN-S
Yes
System configuration TT
Yes
System configuration other
Yes
Number of poles
3
Lightning impulse current (10/350 µs)
12.5 kA
Max. continuous voltage AC
280 V
Max. continuous voltage DC
0 V
Nominal voltage AC
280 V
Nominal voltage DC
0 V
Max. PV-voltage
0 V
Voltage protection level
1.5 kV
Voltage protection level L-N
0 kV
Voltage protection level L-PE
1.5 kV
Voltage protection level N-PE
0 kV
Voltage protection level (DC+ - DC-)
0 kV
Voltage protection level (DC+/DC- - PE)
0 kV
Follow current extinguishing capability
0 kA
Specific energy (W/R)
39.1 kJ/Ohm
Max. overcurrent protection device, parallel connection (fuse)
0 A
Max. overcurrent protection device, series connection (fuse)
160 A
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
3 modular spacing
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
Remote signalling
No
Signalling at the device
Optical
Test class
Type 1 + 2
Integrated backup fuse
No
Energy-coordinated protection effect with regard to the terminal equipment
No
Voltage switching spark gap technology
No
Overcurrent protected voltage tapping
No
Degree of protection (IP)
IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.