I/O module, 100-240VAC, for MFD-AC-CP8, 12DI, 4DO relays - EATON - MFD-AC-R16 - 274093 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

I/O module, 100-240VAC, for MFD-AC-CP8, 12DI, 4DO relays - EATON - MFD-AC-R16 - 274093





Ship on today

I/O module, 100-240VAC, for MFD-AC-CP8, 12DI, 4DO relays

More details

Programmable Relays


easyHMI - MFD-Titan - I/O expansions - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

Price: $118.38
*This price is per unit and is the net value (not including taxes if applicable).
Up to 35% discount for registered clients.

Request a quote
How it Works

How does the quotation request work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with our price proposals
4 You can directly process the order for the quotation

There are several options for payment
- Credit card
- Wire Transfer
- PayPal

More info

Delivery programme
Supply voltage
  100 - 240 V AC
Relay 10 A (UL)
Temperature range
Temperature detector
For use with
Technical data
  EN 61000-6-1/-2/-3/-4, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
Dimensions (W x H x D)
 mm89 x 90 x 44
  Fitted into the power supply unit.
Terminal capacities
 mm20.2⁄4 (AWG 24 - 12)
Flexible with ferrule
 mm20.2⁄2.5 (AWG 24 - 12)
Standard screwdriver
 mm3.5 x 0.6
Climatic environmental conditions
Operating ambient temperature
 °C-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2
  Take appropriate measures to prevent condensation
 °C- 40 - 70
Relative humidity, non-condensing (IEC/EN 60068-2-30)
 %5 - 95
Air pressure (operation)
 hPa795 - 1080
Ambient conditions, mechanical
Pollution degree
Protection type (IEC/EN 60529, EN50178, VBG 4)
Vibrations (IEC/EN 60068-2-6)
Constant amplitude 0.15 mm
 Hz10 - 57
Constant acceleration 2 g
 Hz57 - 150
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
Drop to IEC/EN 60068-2-31
Drop heightmm50
Free fall, packaged (IEC/EN 60068-2-32)
Mounting position
  Vertical or horizontal
Electromagnetic compatibility (EMC)
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD)
Air discharge
Contact discharge
Electromagnetic fields (RFI) to IEC EN 61000-4-3
Radio interference suppression
  EN 55011 Class B, EN 55022 Class B
Burst Impulse (IEC/EN 61000-4-4, Level 3)
Supply cable
Signal lines
Power pulses (surge) (IEC/EN 61000-4-5)
 kV2 (supply cables, symmetrical)
power pulses (surge) (IEC/EN 61000-4-5, level 2)
 kV0.5 (symmetrical power lines)
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
Insulation resistance
Clearance in air and creepage distances
  EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance
  EN 50178
Power supply
Heat dissipation
Digital inputs 115/230 V AC
Status indication
  LCD-display (if present)
Potential isolation
From power supply
Between digital inputs
From the outputs
From the PC interface, memory card NET network, EASY-Link
Rated voltage L (sinusoidal)
 V AC 
On 0 signal
 V AC0 - 40
On 1 signal
 V AC79 - 264
Rated frequency
 Hz50 - 60
Input current on 1 signal
I1 - I12
 mA12 x 0.2 (at 115 V AC, 60 Hz), 12 x 0.5 (at 230 V AC, 50 Hz)
Delay time
Delay time (0 - 1⁄1 - 0) I1 - I12, 50⁄60 Hz
Max. admissible cable length (per input)
I1 - I12
 mNormally 60
Relay outputs
Parallel switching of outputs for increased output
  Not permissible
Protection of an output relay
  Miniature circuit-breaker B16 or fuse 8 A (slow)
Potential isolation
From power supply
From the inputs
From the PC interface, memory card NET network, EASY-Link
Safe isolation according to EN 50178
 V AC300
Basic insulation
 V AC600
Lifespan, mechanical
Operationsx 10610
Conventional thermal current (10 A UL)
Recommended for load: 12 V AC/DC
 mA> 500
Short-circuit-proof cos ϕ = 1, characteristic B16 at 600 A
Short-circuit-proof cos ϕ = 0.5 to 0.7, characteristic B16 at 900 A
Rated impulse withstand voltage Uimp of contact coil
Rated operational voltage
UeV AC250
Rated insulation voltage
UiV AC250
Safe isolation to EN 50178 between coil and contact
 V AC300
Safe isolation to EN 50178 between 2 contacts
 V AC300
Making capacity
AC-15, 230 V AC, 3 A
Operations 300000
DC-13, 24 V DC, 5 A, 0.1 Hz
Operations 200000
Breaking capacity
AC-15, 250 V AC, 3 A (600 Ops./h)
Operations 300000
DC-13, L/R
Technical data for design verification
Rated operational current for specified heat dissipation
Heat dissipation per pole, current-dependent
Equipment heat dissipation, current-dependent
Static heat dissipation, non-current-dependent
Heat dissipation capacity
Operating ambient temperature min.
Operating ambient temperature max.
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
  Meets the product standard's requirements. Verification of thermal stability of enclosures
  Meets the product standard's requirements. Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements. Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Meets the product standard's requirements.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Product Standards  IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking
UL File No.  E135462
UL Category Control No.  NRAQ
CSA File No.  012528
CSA Class No.  2252-01 + 2258-02
North America Certification  UL listed, CSA certified
Degree of Protection  IEC: IP20, UL/CSA Type: -
IL05013014Z (AWA2528-2019) Multi function display, Control relay easy

PDF of I/O module, 100-240VAC, for MFD-AC-CP8, 12DI, 4DO relays - EATON - MFD-AC-R16 - 274093

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait

* Required fields