+IP23/02 200623 EATON ELECTRIC Housing, IP23 x, HxWxD 192x184x160mm, for transformer View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

+IP23/02 200623 EATON ELECTRIC Housing, IP23 x, HxWxD 192x184x160mm, for transformer

+IP23/02

200623

EATON-MOELLER

Housing, IP23_x, HxWxD=192x184x160mm, for transformer. Can only be sold assembled.

+IP23/02

IP23 enclosures, For use with STZ0.2 … STZ0.5

More details


Low-voltage industrial components > Empty enclosure for switchgear

Transformers

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article is restricted. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



IP23 enclosures, For use with STZ0.2 … STZ0.5
IP23 enclosure for STZ0.2 to STZ0.5, enclosure can be used with primary or secondary voltage > 110 V

General specifications
Product name
Eaton Moeller® series Accessory Housing
Part no.
+IP23/02
EAN
4015082006235
Product Length/Depth
192 millimetre
Product height
184 millimetre
Product width
160 millimetre
Product weight
1.9 kilogram
Certifications
UL Listed
Product Tradename
None
Product Type
Accessory
Product Sub Type
Housing
Catalog Notes
Electrical characteristics: all details for no-load loss, short-circuit loss (copper losses), short-circuit voltage and efficiency values relate to a temperature of 20 °C
Features & Functions
Enclosure material
Steel
Features
Separate windings
General information
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
40 °C
Degree of protection
IP23
NEMA Other
Duty factor
100 %
Insulation class
F
B
Model
Built-in
Product category
Accessories
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
39 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
Radiated heat dissipation with separate mounting
39 W (at an ambient temperature of 20 °C)
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Empty enclosure for switchgear (EC000712)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Empty housing for switch devices (ecl@ss13-27-37-13-01 [AKN343019])
Housing material
Steel
Width
160 mm
Height
184 mm
Depth
192 mm
With transparent cover
No
Suitable for emergency stop
No
Model
Built-in
Degree of protection (IP)
IP23
Degree of protection (NEMA)
Other

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.