DA1-32024FB-A20N
169173
EATON-MOELLER
1
PowerXL Drive - Series DA1
Home > EATON - MOELLER
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Range | Frequency converter | ||
Type identifier | DA1 | ||
Rated voltage of employment | Ue | 230 V AC, three-phase 240 V AC, 3-phasig | |
Output voltage (Ue | UTwo | 230 V AC, three-phase 240 V AC, 3-phasig | |
Mains voltage (50/60Hz) | ULN | V | 200 (-10%) - 240 (+10%) |
Rated current job | |||
for an overload of 150 % | Ie | Has | Twenty four |
Note | Rated current of employment at a switching frequency of 4 kHz and an ambient air temperature of +50 °C | ||
Note | Cycle of overload for 60 s every 600 s | ||
Engine power corresponding | |||
Note | For three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500 tr/min)-1at 50 Hz and 1800-1at 60 Hz | ||
Note | Cycle of overload for 60 s every 600 s | ||
Note | at 230 V, 50 Hz | ||
150 % Overload | P | kW | 5.5 |
150 % Overload | Ie | Has | 19.6 |
Note | under 220 - 240 V, 60 Hz | ||
150 % Overload | P | HP | 7.5 |
150 % Overload | Ie | Has | Twenty two |
Degree of protection | IP20/NEMA 0 | ||
Interface/field bus (built-in) | OP-Bus (RS485)/Modbus RTU, CANopen® | ||
Module coupling to field bus (option) | Ethernet IP DeviceNet PROFIBUS PROFINET Modbus-TCP EtherCAT BACnet/IP SmartWire-DT | ||
Equipment | Filter interference suppression Braking unit Display bright 7-segment | ||
Size | FS3 | ||
Connection to SmartWire-DT | with module SmartWire-DT DX-NET-SWD1 |
General | |||
Compliance with standards | General requirements : IEC/EN 61800-2 Requirements EMC : IEC/EN 61800-3 Safety requirements : IEC/EN 61800-5-1 | ||
Certifications | CE, cUL, UL, c-Tick, Ukr Sepro, EAC | ||
Manufacturing quality | RoHS, ISO 9001 | ||
Climate resilience | ρw | % | < 95 %, average relative humidity (RH), non-condensing, non-corrosive (EN 50178) |
Ambient temperature | |||
Service (150 % surcharge). | ϑ | °C | -10 - +50 |
Storage | ϑ | °C | -40 - +60 |
Level of interference suppression | |||
Class interference suppression (EMC) | C1, C2, C3 ; depends on the length of the connection cable to the motor, the connected load and the environment. If applicable, filters, surge suppressor, external (optional) are necessary. | ||
Environment (EMC) | 1st and 2nd environment | ||
maximum length of motor cable | I | m | C1 ≤ 1 m C2 ≤ 5 m C3 ≤ 25 m |
Mounting Position | Vertical | ||
Altitude of installation | m | 0 - 1000 m above sea level above 1000 m : 1 % derating power 100 m max. 4000 m | |
Degree of protection | IP20/NEMA 0 | ||
Protection against direct contacts | BGV A3 (VBG4, protection against contact with the fingers and the back of the hand) | ||
Main Circuit | |||
Power | |||
Rated voltage of employment | Ue | 230 V AC, three-phase 240 V AC, 3-phasig | |
Mains voltage (50/60Hz) | ULN | V | 200 (-10%) - 240 (+10%) |
Input current (overload 150 %) | ILN | Has | 24.8 |
Power | Networks of alternating current with the middle point connected to earth | ||
Network frequency | fLN | Hz | 50/60 |
Frequency range | fLN | Hz | 48 - 62 |
Frequency power | every 30 seconds | ||
Power part | |||
Function | Frequency converters with intermediate circuit dc voltage and inverter IGBT | ||
Overload current (overload 150 %) | IThe | Has | Thirty six |
Peak current at start-up max. (High Overload) | IH | % | Two hundred |
A note about the peak current at start-up max. | for 4 seconds | ||
Output voltage (Ue | UTwo | 230 V AC, three-phase 240 V AC, 3-phasig | |
Output frequency | fTwo | Hz | 0 - 50/60 (max. 500) |
Clock frequency | fPWM | kHz | Sixteen adjustable 4 - 16 (audible) |
Operation | Command U/f Speed regulation with slip compensation Control vector without sensor (SLV) in option : control-vector with feedback (CLV) | ||
Resolution of the frequency (setpoint) | Δf | Hz | 0.1 |
Rated current job | |||
for an overload of 150 % | Ie | Has | Twenty four |
Note | Rated current of employment at a switching frequency of 4 kHz and an ambient air temperature of +50 °C | ||
Power dissipated | |||
Power dissipated under current assigned job | PV | W | 170.5 |
Performance | η | % | 96.9 |
Leakage current maximum at the ground (PE) without motor | IPE | my | 0.93 |
Equipment | Filter interference suppression Braking unit Display bright 7-segment | ||
Safety function | STO (Safe Torque Off) | ||
Size | FS3 | ||
Start engine | |||
Note | For three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500 tr/min)-1at 50 Hz and 1800-1at 60 Hz | ||
Note | Cycle of overload for 60 s every 600 s | ||
Note | at 230 V, 50 Hz | ||
150 % Overload | P | kW | 5.5 |
Note | under 220 - 240 V, 60 Hz | ||
150 % Overload | P | HP | 7.5 |
Maximum permissible length of cable | I | m | shielded: 100 shielded, with inductance motor: 200 non-shielded: 150 non-armoured, with inductance motor: 300 |
Apparent power | |||
Apparent power in rated service 230 V | S | kVA | 9.56 |
Apparent power in rated service 240 V | S | kVA | 9.98 |
Braking function | |||
Braking torque Standard | max. 30 % MN | ||
Braking torque Braking dc | 100 %, adjustable | ||
Braking torque with external braking resistor | max. 100% of the rated current of job Ie with external braking resistor | ||
External braking resistor min. | Rmin | Ω | Twenty |
Activation threshold for the braking transistor | UDC | V | 390 V DC |
Part command | |||
control voltage external | Uc | V | 24 V DC (max. 100 mA) |
Voltage setpoint | Us | V | 10 V DC (max. 10 mA) |
Analog inputs | 2, configurable 0 - 10 V DC, 0/4 - 20 mA | ||
Analog outputs | 2, configurable 0 - 10 V, 0/4 - 20 mA | ||
Entries all-or-nothing | 3, configurable, 30 V DC max., 5 max. with analog inputs, non-parameterized | ||
Outputs all-or-nothing | 2, user configurable, 24 V DC | ||
Relay outputs | 2, software, with 1 normally open contact and 1 changeover contact, 6 A (250 V, AC-1) / 5 A (30 V, DC-1) | ||
Interface/field bus (built-in) | OP-Bus (RS485)/Modbus RTU, CANopen® | ||
Organs of control and protection suitable | |||
Connection to the network | |||
(IEC Type B, gG), 150 % | FAZ-B32/3 | ||
UL listed (Class CC or J) | Has | Thirty two | |
150 % overload (CT/IH at 50 °C) | DX-LN3-025 | ||
Start engine | |||
150 % overload (CT/IH at 50 °C) | DX-LM3-035 | ||
150 % overload (CT/IH at 50 °C) | DX-SIN3-032 | ||
10 % duty cycle (FM) | DX-BR022-1K4 | ||
20 % duty cycle (FM) | DX-BR022-3K1 |
Technical specifications for verification of design | |||
Rated current job for indication of the power dissipated | In | Has | Twenty four |
Power dissipated in the material, a function of the current | Pvid | W | 170.5 |
Certificate for IEC/EN 61439 | |||
10.2 Strength of materials and parts | |||
10.2.2 Resistance to corrosion | The requirements of the product standard are met. | ||
10.2.3.1 heat Resistance of the envelope | The requirements of the product standard are met. | ||
10.2.3.2 Resistance of insulating Materials to Heat normal | The requirements of the product standard are met. | ||
10.2.3.3 Resistance insulating Materials for outstanding Warmth | The requirements of the product standard are met. | ||
10.2.4 Resistance to UV | The requirements of the product standard are met. | ||
10.2.5 Elevation | Without object to the fact that the entire apparatus must be evaluated. | ||
10.2.6 shock Test | Without object to the fact that the entire apparatus must be evaluated. | ||
10.2.7 Inscriptions | The requirements of the product standard are met. | ||
10.3 Degree of protection of the envelope | Without object to the fact that the entire apparatus must be evaluated. | ||
10.4 isolation Distances and lines of flight | The requirements of the product standard are met. | ||
10.5 Protection against electric shock | Without object to the fact that the entire apparatus must be evaluated. | ||
10.6 Mounting hardware | Without object to the fact that the entire apparatus must be evaluated. | ||
10.7 electrical Circuits and connections internal | Under the responsibility of the tableautier. | ||
10.8 Connections for the conductors passed from the outside | Under the responsibility of the tableautier. | ||
10.9 Properties of isolation | |||
10.9.2 withstand Voltage at industrial frequency | Under the responsibility of the tableautier. | ||
10.9.3 there Voltage shock | Under the responsibility of the tableautier. | ||
10.9.4 Test envelope insulation | Under the responsibility of the tableautier. | ||
10.10 Warm-up | The calculation of the warm-up is under the responsibility of the tableautier. Eaton provides the data of the dissipated power of the devices. | ||
10.11 resistance to short-circuits | Under the responsibility of the tableautier. The specifications of the devices must be observed. | ||
10.12 electromagnetic Compatibility | Under the responsibility of the tableautier. The specifications of the devices must be observed. | ||
10.13 mechanical Operation | At the level of the device, the required conditions are met, to the extent the instructions of the installation manual (IT) are taken into account. |
voltage | V | 200 - 240 | |
frequency of the sector | 50/60 Hz | ||
number of input phases | Three | ||
number of phases output | Three | ||
output frequency max. | Hz | Five hundred | |
output voltage: max. | V | Two hundred thirty | |
output current nominal I2N | Has | Twenty four | |
output power max. support quadratic in output voltage rated | kW | 5.5 | |
output power max. linear load voltage output rated | kW | 5.5 | |
with control element | yes | ||
use permitted in an industrial zone | yes | ||
permitted use in residential and commercial area | yes | ||
supported protocol for TCP/IP | not | ||
supported protocol for PROFIBUS | yes | ||
supported protocol for CAN | yes | ||
supported protocol for INTERBUS | not | ||
supported protocol for ASI | not | ||
supported protocol for KNX | not | ||
supported protocol for MODBUS | yes | ||
supported protocol for Data-Highway | not | ||
supported protocol for DeviceNet | not | ||
supported protocol for SUCONET | not | ||
supported protocol for LON | not | ||
supported protocol for PROFINET IO | yes | ||
supported protocol for PROFINET CBA | not | ||
supported protocol for SERCOS | not | ||
supported protocol for Foundation Fieldbus | not | ||
supported protocol for EtherNet/IP | yes | ||
supported protocol for AS-Interface Safety at Work | not | ||
supported protocol for DeviceNet Safety | not | ||
supported protocol for INTERBUS-Safety | not | ||
supported protocol for PROFIsafe | not | ||
supported protocol for SafetyBUS p | not | ||
supported protocol for other bus systems | not | ||
number of hardware interfaces Industrial Ethernet | Zero | ||
number of hardware interfaces PROFINET | Zero | ||
number of hardware interfaces RS-232 serial | Zero | ||
number of hardware interfaces serial RS-422 | Zero | ||
number of hardware interfaces RS-485 serial | One | ||
number of hardware interfaces serial TTY | Zero | ||
number of hardware interfaces USB | One | ||
number of hardware interfaces parallel | Zero | ||
a number of other hardware interfaces | Zero | ||
with optical interface | not | ||
with connection to PC | yes | ||
chopper integrated brake | yes | ||
operation possible in four quadrants | not | ||
type of converter | converter U | ||
protection class (IP) | IP20 | ||
height | mm | Two hundred seventy three | |
width | mm | One hundred thirty one | |
depth | mm | Two hundred four | |
tolerance relative frequency of the symmetrical network | % | Five | |
relative tolerance of voltage of the symmetrical network | % | Ten |
Product Standards | UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking | ||
UL File No. | E172143 | ||
UL Category Control No. | NMMS, NMMS7 | ||
CSA File No. | UL report applies to both US and Canada | ||
North America Certification | UL listed, certified by UL for use in Canada | ||
Specially designed for North America | No. | ||
Suitable for | Branch circuits | ||
Max. Voltage Rating | 3~ 240 V AC IEC: TN-S UL/CSA: Y (Solidly Grounded Wey) | ||
Degree of Protection | IEC: IP20 |
IL04020010Z frequency converter DA1 (FS2 - FS3, IP20) | |||
MN04020005Z frequency converter DA1, user manual | |||
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE EATON EN.pdf | 51 Mbytes | |
DA1-32024FB-A20N 169173 169173_EN.pdf | 205 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.