M22-E4 216545 EATON MOELLER Flush mounting plate, 4 mounting locations View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

M22-E4 216545 EATON MOELLER Flush mounting plate, 4 mounting locations

M22-E4

216545

EATON - MOELLER

Available

Ship on today

Flush mounting plate, 4 mounting locations

More details


Signaling Signalization Rotating Beacons

RMQ-Titan pilot devices - EATON - MOELLER

Flush Mounting Panels, Shrouds - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$16.42
11+$14.45
21+$14.12
31+$13.95
41+$13.84
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  RMQ-Titan (drilling dimensions 22.5 mm)
Basic function
  Accessories
Accessories
  Surface mounting enclosure
Basic function accessories
  Flush mounting plates
Single unit/Complete unit
  Single unit
 
  No legend plates possible with vertical arrangements
Degree of protection only in conjunction with a suitable enclosure and correct mounting.
Aluminium light anodized, including M22-XE...
Degree of Protection
  IP65
Number of locations
 Qty.4
Colour
   
 
  
General
Ambient temperature
   
Open
 °C-25 - +70
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA0
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Please enquire
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  Not applicable.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Built-in panel for control circuit devices (EC000201)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Low-voltage switch technology (accessories) / Installation plate for command devices ([email protected] [ACO025008])
Width
 mm171
Height
 mm72
Material
  Aluminium
Number of command positions
  4
Diameter openings
 mm22
Colour
  -
Approvals
Product Standards  IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL File No.  E29184
UL Category Control No.  NKCR
CSA File No.  012528
CSA Class No.  3211-03
North America Certification  UL listed, CSA certified
Degree of Protection  UL/CSA Type 3R, 4X, 12, 13
Dimensions
IL04716003Z (AWA1160-1746) RMQ-Titan System
 
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or