NZM-XDMI-DPV1 270333 EATON MOELLER Fieldbus connection, profibus-DPV1-Slave View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM-XDMI-DPV1 270333 EATON MOELLER Fieldbus connection, profibus-DPV1-Slave

NZM-XDMI-DPV1

270333

EATON - MOELLER

Available

Ship on today

Fieldbus connection, profibus-DPV1-Slave

More details


Circuit Breakers Electrical Power

Circuit-breakers NZM and LZM (Accessories) - EATON - MOELLER

Circuit-breakers NZM and LZM (Accessories) - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$464.53
2+$463.39
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Accessories
Accessories
  Diagnostics, communication
Description
  

Connection to the DMI module

  • Transfer of phase currents, parameter data, status data and diagnostics data.
  • Transfer of circuit-breaker position (wiring of auxiliary contacts to DMI inputs).
  • Actuation of the DMI motor starter functions and the NZM remote operator.
  • Detection of digital inputs and actuation via field Bus.
  • PROFIBUS-DPV1-Slave fieldbus interface. Can be operated with class 1 and class 2 masters. Addresses available: 1 to 126.
Bus protocol
  PROFIBUS-DP
Notes 

Connected to the DMI module and has the same contour appearance.

Technical data
General
Standards
  EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
Dimensions (W x H x D)
 mm35.5 x 90 x 58 (2 PE)
Weight
 kg0.15
Mounting
  Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Terminal capacities
Solid
 mm20.2 … 4 (AWG 22 … 12)
Flexible with ferrule
 mm20.2 … 2.5 (AWG 22 … 12)
Standard screwdriver
 mm3.5 x 0.8
Max. tightening torque
 Nm0.6
Climatic environmental conditions
Operating ambient temperature
 °C-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2
Condensation
  Take appropriate measures to prevent condensation
Storage
 °C- 40 - 70
Relative humidity, non-condensing (IEC/EN 60068-2-30)
 %5 - 95
Air pressure (operation)
 hPa795 - 1080
Corrosion resistance
 cm³/m³ 
IEC/EN 60068-2-42
4 days SO2cm3/m310
IEC/EN 60068-2-43
4 days H2Scm3/m31
Ambient conditions, mechanical
Pollution degree
  2
Protection type (IEC/EN 60529, EN50178, VBG 4)
  IP20
Vibrations (IEC/EN 60068-2-6)
 Hz 
Constant amplitude 0.15 mm
 Hz10 - 57
Constant acceleration 2 g
 Hz57 - 150
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
 Impacts18
Drop to IEC/EN 60068-2-31
Drop heightmm50
Free fall, packaged (IEC/EN 60068-2-32)
 m1
Mounting position
  Vertical or horizontal
Electromagnetic compatibility (EMC)
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD)
 kV 
Air discharge
 kV8
Contact discharge
 kV6
Electromagnetic fields (RFI) to IEC EN 61000-4-3
 V/m10
Radio interference suppression
  EN 55011 Class B, EN 55022 Class B
Burst Impulse (IEC/EN 61000-4-4, Level 3)
   
Supply cable
 kV2
Signal lines
 kV2
power pulses (surge) (IEC/EN 61000-4-5, level 2)
 kV0.5 (supply cables, symmetrical)
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
 V10
Insulation resistance
Clearance in air and creepage distances
  EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance
  EN 50178
Power supply
Rated operational voltage
UeV24 (-15/+20 %)
Admissible range
 V DC20.4 - 28.8
Residual ripple
 %< 5
at 24 V DC
 mANormally 200
Voltage dips
 ms≤ 10
Heat dissipation at 24 V DC
 W4.8
Protection against polarity reversal
AS-I power supply
  Yes
LEDs
Supply
  Power LED (POW): green
LED display
  PROFIBUS-DP LED (BUS): red
Network
Connection technique
  SUB-D 9 pole, socket
Potential isolation
  Between bus and power supply (simple), between bus and power supply and NZM-XDMI612 (safe isolation)
Function
  PROFIBUS-DP slave
Interface
  RS485
Bus protocol
  PROFIBUS-DP
Baud rates
  Automatic search up to 12 MBit⁄s
Bus terminating resistors
  Separate external bus termination required
Bus addresses
  1 … 126 via DMI
Services
   
Cyclic
  Status ON/OFF/tripped (detailed),

load early warnings,

phase currents I1/I2/I3 [A],

remote operator actuation,

display/operation NZM-XDMI612 inputs/outputs,

motor starter functions
Acyclic
  Display/match protection settings,

event list,

identification,

hours of operation,

switching operations,

time
Design verification as per IEC/EN 61439(Show features)(Hide features)
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
PLC's (EG000024) / Fieldbus, decentr. periphery - communication module (EC001604)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - communications module ([email protected] [BAA073010])
Supply voltage AC 50 Hz
 V0 - 0
Supply voltage AC 60 Hz
 V0 - 0
Supply voltage DC
 V0 - 0
Voltage type of supply voltage
  DC
Supporting protocol for TCP/IP
  No
Supporting protocol for PROFIBUS
  Yes
Supporting protocol for CAN
  No
Supporting protocol for INTERBUS
  No
Supporting protocol for ASI
  No
Supporting protocol for KNX
  No
Supporting protocol for MODBUS
  No
Supporting protocol for Data-Highway
  No
Supporting protocol for DeviceNet
  No
Supporting protocol for SUCONET
  No
Supporting protocol for LON
  No
Supporting protocol for SERCOS
  No
Supporting protocol for PROFINET IO
  No
Supporting protocol for PROFINET CBA
  No
Supporting protocol for Foundation Fieldbus
  No
Supporting protocol for EtherNet/IP
  No
Supporting protocol for AS-Interface Safety at Work
  No
Supporting protocol for DeviceNet Safety
  No
Supporting protocol for INTERBUS-Safety
  No
Supporting protocol for PROFIsafe
  No
Supporting protocol for SafetyBUS p
  No
Supporting protocol for other bus systems
  No
Radio standard Bluetooth
  No
Radio standard WLAN 802.11
  No
Radio standard GPRS
  No
Radio standard GSM
  No
Radio standard UMTS
  No
IO link master
  No
System accessory
  Yes
Degree of protection (IP)
  IP20
With potential separation
  No
Fieldbus connection over separate bus coupler possible
  No
Rail mounting possible
  Yes
Wall mounting/direct mounting
  No
Front build in possible
  Yes
Rack-assembly possible
  No
Suitable for safety functions
  No
Category according to EN 954-1
  -
SIL according to IEC 61508
  None
Performance level acc. to EN ISO 13849-1
  None
Appendant operation agent (Ex ia)
  No
Appendant operation agent (Ex ib)
  No
Explosion safety category for gas
  None
Explosion safety category for dust
  -
Width
 mm35
Height
 mm90
Depth
 mm55
Dimensions
IL01219007Z (AWA1230-2123) Field Bus Connection PROFIBUS-DP
 
>
>
>>

Datasheet - PDF