Fieldbus connection, profibus-DPV1-Slave - EATON - NZM-XDMI-DPV1 - 270333 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

Fieldbus connection, profibus-DPV1-Slave - EATON - NZM-XDMI-DPV1 - 270333





Ship on today

Fieldbus connection, profibus-DPV1-Slave

More details

Circuit Breakers Electrical Power

Circuit-breakers NZM and LZM (Accessories) - EATON - MOELLER

Circuit-breakers NZM and LZM (Accessories) - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

Price: $475.18
*This price is per unit and is the net value (not including taxes if applicable).
Up to 35% discount for registered clients.

Request a quote
How it Works

How does the quotation request work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with our price proposals
4 You can directly process the order for the quotation

There are several options for payment
- Credit card
- Wire Transfer
- PayPal

More info

Delivery programme
Product range
  Diagnostics, communication

Connection to the DMI module

  • Transfer of phase currents, parameter data, status data and diagnostics data.
  • Transfer of circuit-breaker position (wiring of auxiliary contacts to DMI inputs).
  • Actuation of the DMI motor starter functions and the NZM remote operator.
  • Detection of digital inputs and actuation via field Bus.
  • PROFIBUS-DPV1-Slave fieldbus interface. Can be operated with class 1 and class 2 masters. Addresses available: 1 to 126.
Bus protocol

Connected to the DMI module and has the same contour appearance.

Technical data
  EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
Dimensions (W x H x D)
 mm35.5 x 90 x 58 (2 PE)
  Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Terminal capacities
 mm20.2 … 4 (AWG 22 … 12)
Flexible with ferrule
 mm20.2 … 2.5 (AWG 22 … 12)
Standard screwdriver
 mm3.5 x 0.8
Max. tightening torque
Climatic environmental conditions
Operating ambient temperature
 °C-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2
  Take appropriate measures to prevent condensation
 °C- 40 - 70
Relative humidity, non-condensing (IEC/EN 60068-2-30)
 %5 - 95
Air pressure (operation)
 hPa795 - 1080
Corrosion resistance
IEC/EN 60068-2-42
4 days SO2cm3/m310
IEC/EN 60068-2-43
4 days H2Scm3/m31
Ambient conditions, mechanical
Pollution degree
Protection type (IEC/EN 60529, EN50178, VBG 4)
Vibrations (IEC/EN 60068-2-6)
Constant amplitude 0.15 mm
 Hz10 - 57
Constant acceleration 2 g
 Hz57 - 150
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
Drop to IEC/EN 60068-2-31
Drop heightmm50
Free fall, packaged (IEC/EN 60068-2-32)
Mounting position
  Vertical or horizontal
Electromagnetic compatibility (EMC)
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD)
Air discharge
Contact discharge
Electromagnetic fields (RFI) to IEC EN 61000-4-3
Radio interference suppression
  EN 55011 Class B, EN 55022 Class B
Burst Impulse (IEC/EN 61000-4-4, Level 3)
Supply cable
Signal lines
power pulses (surge) (IEC/EN 61000-4-5, level 2)
 kV0.5 (supply cables, symmetrical)
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
Insulation resistance
Clearance in air and creepage distances
  EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance
  EN 50178
Power supply
Rated operational voltage
UeV24 (-15/+20 %)
Admissible range
 V DC20.4 - 28.8
Residual ripple
 %< 5
at 24 V DC
 mANormally 200
Voltage dips
 ms≤ 10
Heat dissipation at 24 V DC
Protection against polarity reversal
AS-I power supply
  Power LED (POW): green
LED display
Connection technique
  SUB-D 9 pole, socket
Potential isolation
  Between bus and power supply (simple), between bus and power supply and NZM-XDMI612 (safe isolation)
Bus protocol
Baud rates
  Automatic search up to 12 MBit⁄s
Bus terminating resistors
  Separate external bus termination required
Bus addresses
  1 … 126 via DMI
  Status ON/OFF/tripped (detailed),

load early warnings,

phase currents I1/I2/I3 [A],

remote operator actuation,

display/operation NZM-XDMI612 inputs/outputs,

motor starter functions
  Display/match protection settings,

event list,


hours of operation,

switching operations,

Design verification as per IEC/EN 61439(Show features)(Hide features)
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
  Meets the product standard's requirements. Verification of thermal stability of enclosures
  Meets the product standard's requirements. Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements. Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
PLC's (EG000024) / Fieldbus, decentr. periphery - communication module (EC001604)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - communications module ([email protected] [BAA073010])
Supply voltage AC 50 Hz
 V0 - 0
Supply voltage AC 60 Hz
 V0 - 0
Supply voltage DC
 V0 - 0
Voltage type of supply voltage
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for MODBUS
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Radio standard Bluetooth
Radio standard WLAN 802.11
Radio standard GPRS
Radio standard GSM
Radio standard UMTS
IO link master
System accessory
Degree of protection (IP)
With potential separation
Fieldbus connection over separate bus coupler possible
Rail mounting possible
Wall mounting/direct mounting
Front build in possible
Rack-assembly possible
Suitable for safety functions
Category according to EN 954-1
SIL according to IEC 61508
Performance level acc. to EN ISO 13849-1
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
Explosion safety category for dust
IL01219007Z (AWA1230-2123) Field Bus Connection PROFIBUS-DP

PDF of Fieldbus connection, profibus-DPV1-Slave - EATON - NZM-XDMI-DPV1 - 270333