Voltage type | DC voltage | ||
Contacts | N/O = normally open contact, C/O = changeover contact, P = programmable as N/C or N/O | S | |
Rated switching distance | Sn | mm | 4 |
Rated operating voltage | Ue | V DC | 10 - 30 |
Maximum load current | Ie | mA | 200 |
Style | mm | M12 x 1 | |
Housing | Insulated material | ||
Terminal connection | 2 m connection cable | ||
Fitting in metal | Non-flush | ||
Notes All LSI-…D feature an LED function display and protective functions against:
Connection diagram as per IEC/EN 60947-5-2, 3-wire DC configuration: | |||
General | |||
Standards | IEC/EN 60947-5-2 | ||
Ambient temperature | 25 - 70 | ||
Degree of Protection | IP67 | ||
Characteristics | |||
Rated switching distance | Sn | mm | 4 |
Repetition accuracy of Sn | % | 2 | |
Temperature drift of Sn | % | < 10 | |
Switching hysteresis of Sn | % | 15 | |
Rated operating voltage | Ue | V DC | 10 - 30 |
Residual ripple of Ue | % | ||
Correction factor with LSI: | |||
Steel St 37 | 1.0 | x Sn | |
Nickel chrome | Approx. | 0.9 | x Sn |
Brass | Approx. | 0.5 | x Sn |
Aluminium | Approx. | 0.45 | x Sn |
Copper | Approx. | 0.4 | x Sn |
Galvanized sheet steel | Approx. | 0.85 | x Sn |
Stainless-steel depending on the alloy | 1.0 - 0.1 | x Sn |