XN-2DO-24VDC-2A-P 140055 EATON MOELLER Digital output module XI/ON, 24 V DC, 2DO, 2A, pulse-switching View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

XN-2DO-24VDC-2A-P 140055 EATON MOELLER Digital output module XI/ON, 24 V DC, 2DO, 2A, pulse-switching

XN-2DO-24VDC-2A-P

140055

EATON - MOELLER

Available

Ship on today

Digital output module XI/ON, 24 V DC, 2DO, 2A, pulse-switching

More details


Programmable Logic Controllers Plcs

EC4E & XI/ON Remote I/O system - EATON - MOELLER

Input/output expansion - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$56.50
5+$52.30
10+$51.03
14+$50.50
19+$50.08
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Function
  XI/ON I/O modules
Function
  XN Slice module
Short Description
  2 Digital output, 24 V DC/2 A
Positive switching
For use with
  XN-S3T-SBC
XN-S3S-SBC
XN-S4T-SBCS
XN-S4S-SBCS
Technical data
General
Standards
  EN 61000-6-2
EN 61000-6-4
EN 61131-2
Potential isolation
  Yes, through optocoupler
Ambient temperature
   
Ambient temperature, operation
 °C0 - +55
Storage, transport
ϑ°C-25 - +85
Relative humidity
   
Relative humidity
  5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C)
Ambient conditions, mechanical
   
Degree of Protection
  IP20
Harmful gases
 ppmSO2: 10 (rel. humidity < 75%, no condensation)
H2S: 1.0 (rel. humidity < 75 %,no condensation)
Vibration resistance, operating conditions
  according to IEC/EN 60068-2-6
Mechanical shock resistance
 gaccording to IEC 60068-2-27
Continuous shock resistance (IEC/EN 60068-2-29)
  According to IEC 60068-2-29
Drop and topple
  According to IEC 60068-2-31, free fall according to IEC 60068-2-32
Electromagnetic compatibility (EMC)
   
ESD
 kVEN 61100-4-2
Electromagnetic fields
 V/mEN 61100-4-2
Burst
  EN 61100-4-4
Surge
  EN 61100-4-5
Radiated RFI
  VEN 61100-4-6
Emitted interference (radiated, high frequency)
 dBEN 55016-2-3
Voltage fluctuations/voltage dips
  EN 61131-2
Type test
  to EN 61131-2
Approvals
  CE, cULus
Other technical data (sheet catalogue)
  >Technical Data
Analog input modules
Channels
 Number2
Rated voltage through supply terminal
UL 24 V DC
Rated current consumption from supply terminal
ILmA50
Rated current consumption from module bus
IMBmA
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA0
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW1
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C0
Operating ambient temperature max.
 °C55
Degree of Protection
  IP20
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Meets the product standard's requirements.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
PLC's (EG000024) / Fieldbus, decentr. periphery - digital I/O module (EC001599)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - digital I/O module ([email protected] [BAA055011])
Supply voltage AC 50 Hz
 V0 - 0
Supply voltage AC 60 Hz
 V0 - 0
Supply voltage DC
 V18 - 30
Voltage type of supply voltage
  DC
Number of digital inputs
  0
Number of digital outputs
  2
Digital inputs configurable
  No
Digital outputs configurable
  No
Input current at signal 1
 mA0
Permitted voltage at input
 V0 - 0
Type of voltage (input voltage)
  DC
Type of digital output
  -
Output current
 A2
Permitted voltage at output
 V0 - 29
Type of output voltage
  DC
Short-circuit protection, outputs available
  No
Number of HW-interfaces industrial Ethernet
  0
Number of HW-interfaces PROFINET
  0
Number of HW-interfaces RS-232
  0
Number of HW-interfaces RS-422
  0
Number of HW-interfaces RS-485
  0
Number of HW-interfaces serial TTY
  0
Number of HW-interfaces parallel
  0
Number of HW-interfaces Wireless
  0
Number of HW-interfaces other
  1
With optical interface
  No
Supporting protocol for TCP/IP
  No
Supporting protocol for PROFIBUS
  Yes
Supporting protocol for CAN
  Yes
Supporting protocol for INTERBUS
  No
Supporting protocol for ASI
  No
Supporting protocol for KNX
  No
Supporting protocol for MODBUS
  No
Supporting protocol for Data-Highway
  No
Supporting protocol for DeviceNet
  Yes
Supporting protocol for SUCONET
  No
Supporting protocol for LON
  No
Supporting protocol for PROFINET IO
  No
Supporting protocol for PROFINET CBA
  No
Supporting protocol for SERCOS
  No
Supporting protocol for Foundation Fieldbus
  No
Supporting protocol for EtherNet/IP
  No
Supporting protocol for AS-Interface Safety at Work
  No
Supporting protocol for DeviceNet Safety
  No
Supporting protocol for INTERBUS-Safety
  No
Supporting protocol for PROFIsafe
  No
Supporting protocol for SafetyBUS p
  No
Supporting protocol for other bus systems
  Yes
Radio standard Bluetooth
  No
Radio standard WLAN 802.11
  No
Radio standard GPRS
  No
Radio standard GSM
  No
Radio standard UMTS
  No
IO link master
  No
System accessory
  Yes
Degree of protection (IP)
  IP20
Type of electric connection
  Plug-in connection
Time delay at signal exchange
 ms0 - 0.1
Fieldbus connection over separate bus coupler possible
  Yes
Rail mounting possible
  Yes
Wall mounting/direct mounting
  No
Front build in possible
  No
Rack-assembly possible
  No
Suitable for safety functions
  No
Category according to EN 954-1
  None
SIL according to IEC 61508
  None
Performance level acc. to EN ISO 13849-1
  None
Appendant operation agent (Ex ia)
  No
Appendant operation agent (Ex ib)
  No
Explosion safety category for gas
  None
Explosion safety category for dust
  None
Width
 mm12.6
Height
 mm74.1
Depth
 mm55.4
Approvals
Product Standards  UL 508; CSA-C22.2 No. 142; IEC/EN 6113-2; CE marking
UL File No.  E205091
UL Category Control No.  NRAQ, NRAQ7
CSA File No.  UL report applies to both US and Canada
CSA Class No.  2252-01, 2252-81
North America Certification  UL recognized, certified by UL for use in Canada
Specially designed for North America  No
Current Limiting Circuit-Breaker  No
Degree of Protection  IEC: IP20, UL/CSA Type: -
Dimensions
MN05002010Z Manual Digital XI/ON modules, power supply modules
 
>
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or