Product name
Eaton XIOC Output module
Product Length/Depth
100 millimetre
Product height
95 millimetre
Product width
30 millimetre
Product weight
0.175 kilogram
Certifications
CSA
CSA-C22.2 No. 142-M
UL508
UL Category Control No.: NRAQ
IEC/EN 61131-2
EN 50178
CE
CSA File No.: 012528
CSA-C22.2 No. 0-M
CSA Class No.: 2252-01
UL
UL File No.: E135462
Product Type
Output module
Electric connection type
Screw-/spring clamp connection
Functions
Overvoltage protection (external)
Admissible range
20.4 – 28.8 V (11.8 – 14.4 V), Power supply
Current consumption
40 mA, Internal current consumption (5 V DC), Outputs
Number of channels
12, Output
Protection
Protection class: 1
Used with
XC100/200 (expandable with up to 15 XI/OC modules)
Ambient conditions, mechanical
Impact resistance
500 g/⌀ 50 mm ±25 g
Shock resistance
15 g, Mechanical, Shock duration 11 ms
Vibration resistance
57 - 150 Hz ± 1.0 mm
10 - 57 Hz, ± 0.075 mm
Climatic environmental conditions
Ambient operating temperature - min
0 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-25 °C
Ambient storage temperature - max
70 °C
Electro magnetic compatibility
Emitted interference
Class A (according to DIN/EN 55011/22)
Terminals
Optionally, screw terminals or spring-loaded terminals for digital/analog modules
Mains voltage tolerance
24 V DC (-15/+20 %, max. 70 mA)
Rated control voltage (Uc)
100/240 V AC
Rated operational current (Ie)
5 A at AC-3, 230 V
2 A at DC-13, 110 V
Rated operational voltage
24 (12) V DC
Short-circuit protection
Fuse, Outputs, External
Supply voltage at AC, 50 Hz - min
0 V AC
Supply voltage at AC, 50 Hz - max
0 V AC
Supply voltage at DC - min
20.4 V DC
Supply voltage at DC - max
28.8 V DC
Connection type
Plug-in terminal block, Power supply
LED indicator
Status indication: Green LED
Delay time
10 ms typ., Outputs, Delay time from 1 to 0, Debounce OFF
10 ms, Outputs, Off -> On, Debounce OFF
Input current at signal 1
0 mA
Number of inputs (digital)
0
Number of outputs (digital)
12
Output
12 Relay Outputs
Relay
Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Outputs: Opto-isolated
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0.2 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.