EMR4-I15-1-B 106944 EATON ELECTRIC Current monitoring relay, 2 W, 0,3 1,5 A, 1 -5 A, 3 15 A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EMR4-I15-1-B 106944 EATON ELECTRIC Current monitoring relay, 2 W, 0,3 1,5 A, 1 -5 A, 3 15 A

EMR4-I15-1-B

106944

EATON-MOELLER

Current monitoring relay, 2 W, 0,3 - 1,5 A, 1 -5 A, 3 - 15 A

More details


Relays > Current monitoring relay

Relay timers (KETR, KEMR, KESR)

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: EMR6-I15-B-1 184755

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Current monitoring relay, 2 W, 0,3 - 1,5 A, 1 -5 A, 3 - 15 A
Eaton Catalog No.
EMR4-I15-1-B
EL-Nummer (Norway)
4110380
Current monitoring relay single-phase EMR4-I... 60255-6 according to IEC/EN, 22.5 mm wide, current measuring ranges: 0.3-1.5A, 1-5A, 3-15A, switching hysteresis adjustable from 3-30%, response delay 0.1-30s, monitoring of the upper and lower limit, 220-240VAC
[

Delivery program

This item will continue to be available for a limited time only and is being replaced by the following item: 184755, EMR6-I15-B-1
Product range
EMR Measuring and monitoring relays
Basic function
Current monitoring relays
Monitoring of single-phase DC and AC networks
Switching hysteresis adjustable from 3 – 30 %
On delay: None = 0 or adjustable from 0.1 to 30 s
Extension of the measurement range possible with current transformers
Monitoring of
Overcurrent
Undercurrent
Current measuring range [I{unicode_image code_point="223C"}/I=]
0.3 - 1.5 A
1 - 5 A
3 - 15 A A
Contact sequence
Supply voltage
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
Width
22.5 mm
,

Technical data

Technical data in sheet catalogue
Other technical data (sheet catalogue)
Current monitoring relays
,

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
2 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-20 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
,

Technical data ETIM 7.0

Relays (EG000019) / Current monitoring relay (EC001440)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Monitoring equipment (low-voltage switch technology) / Current monitoring equipment ([email protected] [AKF096014])
Type of electric connection
Screw connection
With detachable clamps
No
Single-phase under current possible
Yes
Three-phase under current possible
No
Single-phase over current possible
Yes
Three-phase over current possible
No
Single-phase hysteresis possible
No
Three-phase hysteresis possible
No
Contains function DC-voltage under current
Yes
Contains function DC-voltage over current
Yes
Function DC-current hysteresis
No
Rated control supply voltage Us at AC 50HZ
220 - 240 V
Rated control supply voltage Us at AC 60HZ
220 - 240 V
Rated control supply voltage Us at DC
220 - 240 V
Voltage type for actuating
AC/DC
Current measurement range
0.3 - 15 A
Min. adjustable delay-on energization time
0.1 s
Max. permitted delay-on energization time
30 s
Min. adjustable off-delay time
0 s
Max. permitted off-delay time
0 s
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
2
External current transformer
No
Width
23 mm
Height
78 mm
Depth
110 mm
,

Approvals

Product Standards
IEC 255-6; UL 508; CSA-22.2 No. 14-05; CE marking
UL File No.
E29184
UL Category Control No.
NKCR, NKCR7
CSA File No.
203843
CSA Class No.
3211-03
North America Certification
UL listed, CSA certified
Degree of Protection
IEC: IP20, UL/CSA Type: -
,

Characteristics

Characteristic curve
AC load (resistive)
Characteristic curve
DC load (resistive)
Characteristic curve
Derating factor F with inductive AC load
Characteristic curve
Contact life
S operations
220 V 50 Hz AC-1
360 operations/h
,

Dimensions

]

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.