DILM300/22(RAC500) 208206 EATON MOELLER XTCE300M22C Contactor 3P, 160kW(AC-3,400V) View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM300/22(RAC500) 208206 EATON MOELLER XTCE300M22C Contactor 3P, 160kW(AC-3,400V)

DILM300/22(RAC500)

208206

EATON - MOELLER

Available

Ship on today

XTCE300M22C Contactor 3P, 160kW(AC-3,400V)

More details


DIL Contactors - EATON - MOELLER

DIL Contactors up to 2600A - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Contactors
Application
  Contactors for Motors
Subrange
  Comfort devices greater than 170 A
Utilization category
  AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Connection technique
  Screw connection
Rated operational current
   
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA490
enclosed
IthA350
Conventional free air thermal current, 1 pole
   
open
IthA1000
enclosed
IthA875
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW90
380 V 400 V
PkW160
660 V 690 V
PkW286
1000 V
PkW132
AC-4
   
220 V 230 V
PkW75
380 V 400 V
PkW132
660 V 690 V
PkW229
1000 V
PkW132
Contact sequence
  >
Can be combined with auxiliary contact
  DILM820-XHI…
Actuating voltage
  RAC 500: 250 - 500 V 40 - 60 Hz/250 - 700 V DC
Voltage AC/DC
  AC and DC operation
Contacts
   
N/O = Normally open
  2 N/O
N/C = Normally closed
  2 NC
Auxiliary contacts
   
possible variants at auxiliary contact module fitting options
  on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
Side mounting auxiliary contacts
  >
Instructions
  integrated suppressor circuit in actuating electronics
660 V, 690 V or 1000 V: not directly reversing
Technical data
General
Standards
  IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
   
AC operated
Operationsx 10610
DC operated
Operationsx 10610
Operating frequency, mechanical
   
AC operated
Operations/h 3000
DC operated
Operations/h 3000
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +60
Enclosed
 °C- 25 - + 40
Storage
 °C- 40 - + 80
Mounting position
  >>
Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g10
Auxiliary contacts
   
N/O contact
 g10
N/C contact
 g8
Degree of Protection
  IP00
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof with terminal shroud or terminal block
Weight
   
AC operated
 kg8
DC operated
 kg8
Weight
 kg8
Terminal capacity main cable
   
Flexible with cable lug
 mm250 - 240
Stranded with cable lug
 mm270 - 240
Solid or stranded
 AWG2/0 - 500 MCM
Flat conductor
Lamellenzahl x Breite x DickemmFixing with flat cable terminal or cable terminal blocks
See terminal capacity for cable terminal blocks
Busbar
Breitemm25
Main cable connection screw/bolt
  M10
Tightening torque
 Nm24
Terminal capacity control circuit cables
   
Solid
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Solid or stranded
 AWG2 x (18 - 12)
Control circuit cable connection screw/bolt
  M3.5
Tightening torque
 Nm1.2
Tool
   
Main cable
   
Open-end spanner
 mm16
Control circuit cables
   
Pozidriv screwdriver
 Size2
Main conducting paths
Rated impulse withstand voltage
UimpV AC8000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC1000
Rated operational voltage
UeV AC1000
Safe isolation to EN 61140
   
between coil and contacts
 V AC500
between the contacts
 V AC500
Making capacity (p.f. to IEC/EN 60947)
 A5500
Breaking capacity
   
220 V 230 V
 A5000
380 V 400 V
 A5000
500 V
 A5000
660 V 690 V
 A5000
1000 V
 A950
Component lifespan
   
 
  AC1: See → Engineering, characteristic curves
AC3: See → Engineering, characteristic curves
AC4: See → Engineering, characteristic curves
Short-circuit rating
   
Short-circuit protection maximum fuse
   
Type “2” coordination
   
400 V
gG/gL 500 VA500
690 V
gG/gL 690 VA500
1000 V
gG/gL 1000 VA200
Type “1” coordination
   
400 V
gG/gL 500 VA630
690 V
gG/gL 690 VA630
1000 V
gG/gL 1000 VA250
AC
AC-1
   
Rated operational current
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA490
at 50 °C
Ith =IeA438
at 55 °C
Ith =IeA418
at 60 °C
Ith =IeA400
enclosed
IthA350
Notes
  At maximum permissible ambient air temperature.
Conventional free air thermal current, 1 pole
   
Note
  at maximum permissible ambient air temperature
open
IthA1000
enclosed
IthA875
AC-3
   
Rated operational current
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA300
240 V
IeA300
415 V
IeA300
440V
IeA300
500 V
IeA300
660 V 690 V
IeA300
1000 V
IeA95
Motor rating
PkWh 
220 V 230 V
PkW90
240V
PkW100
380 V 400 V
PkW160
415 V
PkW180
440 V
PkW160
500 V
PkW215
660 V 690 V
PkW286
1000 V
PkW132
AC-4
   
Rated operational current
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA240
240 V
IeA240
380 V 400 V
IeA240
415 V
IeA240
440 V
IeA240
500 V
IeA240
660 V 690 V
IeA240
1000 V
IeA95
Motor rating
PkWh 
220 V 230 V
PkW75
240 V
PkW82
380 V 400 V
PkW132
415 V
PkW142
440 V
PkW140
500 V
PkW172
660 V 690 V
PkW229
1000 V
PkW132
Condensor operation
Individual compensation, rated operational current Ie of three-phase capacitors
   
Open
   
up to 525 V
 A307
690 V
 A177
Max. inrush current peak
 x Ie30
Component lifespan
Operationsx 1060.1
Max. operating frequency
 Ops/h200
DC
Rated operational current, open
   
DC-1
   
60 V
IeA400
110 V
IeA400
220 V
IeA400
440 V
IeA11
DC-3
   
60 V
IeA400
110 V
IeA400
220 V
IeA400
DC-5
   
60 V
IeA400
110 V
IeA400
220 V
IeA400
Current heat loss
3-pole at Ith
 W37
Current heat loss at Ie to AC-3/400 V
 W21
Magnet systems
Voltage tolerance
 x Uc 
UC
  250 - 500 V 40-60 Hz
DC auf Anfrage
AC operated
Pick-upx Uc0.7 x Uc min - 1.15 x Uc max
DC operated
Pick-upx Uc0.7 x Uc min - 1.15 x Uc max
AC operated
Drop-outx Uc0.2 x Uc min - 0.6 x Uc max
DC operated
Drop-outx Uc0.2 x Uc min - 0.6 x Uc max
Power consumption of the coil in a cold state and 1.0 x Uc
   
Note on power consumption
  Control transformer with uk >
on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
>
Normal switching duty
Normal AC induction motor
Operating characteristics
Switch on: from stop
Switch off: during run
Electrical characteristics:
Switch on:up to 6 x Rated motor current
Switch off:up to 1 x Rated motor current
Utility category
100 % AC-3
Typical Applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
fan
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevator
Air-conditioning systems
General drives for manufacturing and processing machines
>
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
>
Switching duty for non-motor loads, 3-pole, 4-pole
Operating characteristics
Non-inductive or slightly inductive loads
Electrical characteristics
Make: 1 x rated current
Break: 1 x rated current
Utilization category
100 % AC-1
Typical applications
Electric heat
>
Short-time loading, 3-pole
Time interval between two loading cycles: 15 minutes
Dimensions
>
>UL/CSA: Approved rating data
>>UL/CSA: UL/CSA: Short Circuit Current Rating (SCCR)
>>Switchgear of Power Factor Correction Systems
>>X-Start - Modern Switching Installations Efficiently Fitted and Wired Securely
>>Mirror Contacts for Highly-Reliable Information Relating to Safety-Related Control Functions
>>Effect of the Cabel Capacitance of Long Control Cables on the Actuation of Contactors
>>Motor starters and Special Purpose Ratings for the North American market
>>Switchgear for Luminaires
>>Standard Compliant and Functionally Safe Engineering Design with Mechanical Auxiliary Contacts
>>The Interaction of Contactors with PLCs
>>Busbar Component Adapters for modern Industrial control panels

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or