DILM9-01(24V50HZ) 276712 EATON MOELLER Contactor, 3p+1N/C, 4kW/400V/AC3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM9-01(24V50HZ) 276712 EATON MOELLER Contactor, 3p+1N/C, 4kW/400V/AC3

DILM9-01(24V50HZ)

276712

EATON - MOELLER

Available

Ship on today

Contactor, 3p+1N/C, 4kW/400V/AC3

More details


Contactor Relays

DIL Contactors - EATON - MOELLER

DIL Contactors up to 170A - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$20.29
7+$18.43
13+$18.03
19+$17.82
25+$17.69
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Contactors
Application
  Contactors for Motors
Subrange
  Contactors up to 170 A, 3 pole
Utilization category
  AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
 
  >
Notes
  Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Connection technique
  Screw terminals
Pole
  3 pole
Rated operational current
   
AC-3
   
380 V 400 V
IeA9
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA22
enclosed
IthA18
Conventional free air thermal current, 1 pole
   
open
IthA50
enclosed
IthA45
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW2.5
380 V 400 V
PkW4
660 V 690 V
PkW4.5
AC-4
   
220 V 230 V
PkW1.5
380 V 400 V
PkW2.5
660 V 690 V
PkW3.6
Contacts
   
N/C = Normally closed
  1 NC
Contact sequence
  >
Instructions
  Contacts to EN 50 012.
with mirror contact.
Can be combined with auxiliary contact
  DILA-XHI(V)..
Voltage AC/DC
  AC operation
Technical data
General
Standards
  IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
   
AC operated
Operationsx 10610
DC operated
Operationsx 10610
Operating frequency, mechanical
   
AC operated
Operations/h 5000
DC operated
Operations/h 5000
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +60
Enclosed
 °C- 25 - 40
Storage
 °C- 40 - 80
Mounting position
  >
Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g10
Auxiliary contacts
   
N/O contact
 g7
N/C contact
 g5
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g5.7
Auxiliary contacts
   
N/O contact
 g3.4
N/C contact
 g3.4
Degree of Protection
  IP20
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Weight
   
AC operated
 kg0.23
DC operated
 kg0.28
Terminal capacity main cable
   
Solid
 mm21 x (0.75 - 4)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2,5)
 
  Also without ferrule.
Solid or stranded
 AWG18 - 10
Main cable connection screw/bolt
  M3.5
Tightening torque
 Nm1.2
Terminal capacity control circuit cables
   
Solid
 mm21 x (0.75 - 4)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
 AWG18 - 14
Control circuit cable connection screw/bolt
  M3.5
Tightening torque
 Nm1.2
Tool
   
Main cable
   
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Control circuit cables
   
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Main conducting paths
Rated impulse withstand voltage
UimpV AC8000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC690
Safe isolation to EN 61140
   
between coil and contacts
 V AC400
between the contacts
 V AC400
Making capacity (p.f. to IEC/EN 60947)
   
 
Up to 690 VA112
Breaking capacity
   
220 V 230 V
 A90
380 V 400 V
 A90
500 V
 A70
660 V 690 V
 A50
Short-circuit rating
   
Short-circuit protection maximum fuse
   
Type “2” coordination
   
400 V
gG/gL 500 VA20
690 V
gG/gL 690 VA16
Type “1” coordination
   
400 V
gG/gL 500 VA35
690 V
gG/gL 690 VA20
AC
AC-1
   
Rated operational current
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA22
at 50 °C
Ith =IeA21
at 55 °C
Ith =IeA21
at 60 °C
Ith =IeA20
enclosed
IthA18
Conventional free air thermal current, 1 pole
   
open
IthA50
enclosed
IthA45
AC-3
   
Rated operational current
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA9
240 V
IeA9
380 V 400 V
IeA9
415 V
IeA9
440V
IeA9
500 V
IeA7
660 V 690 V
IeA5
380 V 400 V
IeA9
Motor rating
PkWh 
220 V 230 V
PkW2.5
240V
PkW3
380 V 400 V
PkW4
415 V
PkW5.5
440 V
PkW5.5
500 V
PkW4.5
660 V 690 V
PkW4.5
AC-4
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA6
240 V
IeA6
380 V 400 V
IeA6
415 V
IeA6
440 V
IeA6
500 V
IeA5
660 V 690 V
IeA4.5
Motor rating
PkWh 
220 V 230 V
PkW1.5
240 V
PkW1.6
380 V 400 V
PkW2.5
415 V
PkW2.8
440 V
PkW3
500 V
PkW2.8
660 V 690 V
PkW3.6
DC
Rated operational current, open
   
DC-1
   
60 V
IeA20
110 V
IeA20
220 V
IeA15
440 V
IeA1.3
DC-3
   
60 V
IeA20
110 V
IeA20
220 V
IeA1.5
440 V
IeA0.2
DC-5
   
60 V
IeA20
110 V
IeA20
220 V
IeA1.5
440 V
IeA0.2
Current heat loss
3-pole at Ith
 W2.7
Current heat loss at Ie to AC-3/400 V
 W0.6
Impedance per pole
 mΩ2.5
Magnet systems
Voltage tolerance
 x Uc 
AC operated
Pick-upx Uc0.8 - 1.1
Drop-out voltage AC operated
Drop-outx Uc0.3 - 0.6
DC operated
Pick-upx Uc0.7 - 1.2
DC operated
Drop-outx Uc0.15 - 0.6
Notes
  at least smoothed two-phase bridge rectifier or three-phase rectifier
Power consumption of the coil in a cold state and 1.0 x Uc
   
50 Hz
Pick-upVA24
50 Hz
SealingVA3.4
50 Hz
SealingW1.2
60 Hz
Pick-upVA30
60 Hz
SealingVA4.4
60 Hz
SealingW1.4
50/60 Hz
Pick-upVA27
25
50/60 Hz
SealingVA4.2
3.3
50/60 Hz
SealingW1.4
1.2
DC operated
Pick-upW3
DC operated
SealingW3
Duty factor
  % DF100
Switching times at 100 % Uc (approximate values)
   
Main contacts
   
AC operated
   
Closing delay
 ms15 - 21
Opening delay
 ms9 - 18
DC operated
 ms 
Closing delay
 ms31
Opening delay
 ms12
Arcing time
 ms10
Lifespan, mechanical; Coil 50/60 Hz
 x 106Mechanical lifespan at 50 Hz approx. 30% lower than under “Technical data, general”
Electromagnetic compatibility (EMC)
Emitted interference
  to EN 60947-1
Interference immunity
  to EN 60947-1
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA9
Heat dissipation per pole, current-dependent
PvidW0.2
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW1.4
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C60
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching ([email protected] [AAB718012])
Rated control supply voltage Us at AC 50HZ
 V24 - 24
Rated control supply voltage Us at AC 60HZ
 V0 - 0
Rated control supply voltage Us at DC
 V0 - 0
Voltage type for actuating
  AC
Rated operation current Ie at AC-1, 400 V
 A14
Rated operation current Ie at AC-3, 400 V
 A9
Rated operation power at AC-3, 400 V
 kW4
Rated operation current Ie at AC-4, 400 V
 A6
Rated operation power Ie at AC-4, 400 V
 kW2.5
Modular version
  No
Number of auxiliary contacts as normally open contact
  0
Number of auxiliary contacts as normally closed contact
  1
Type of electrical connection of main circuit
  Screw connection
Number of normally closed contacts as main contact
  0
Number of main contacts as normally open contact
  3
Approvals
Product Standards  IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.  E29096
UL Category Control No.  NLDX
CSA File No.  012528
CSA Class No.  2411-03, 3211-04
North America Certification  UL listed, CSA certified
Specially designed for North America  No
Characteristics
>
1: Overload relay
2: Suppressor
3: Auxiliary contact modules
>
Squirrel-cage motor
Operating characteristics
Starting:from rest
Stopping:after attaining full running speed
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 1 x rated motor current
Utilization category
100 % AC-3
Typical applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
Fans
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevators
Air conditioning system
General drives in manufacturing and processing machines
>
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Dimensions
>
Contactor with auxiliary contact module
>
CAD data
>Product-specific CAD data
>3D Preview

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or