DILEM-01(230V50/60HZ) 051114 EATON MOELLER Contactor, 3p+1N/C, 4kW/400V/AC3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILEM-01(230V50/60HZ) 051114 EATON MOELLER Contactor, 3p+1N/C, 4kW/400V/AC3

DILEM-01(230V50/60HZ)

051114

EATON - MOELLER

Available

Ship on today

Contactor, 3p+1N/C, 4kW/400V/AC3

More details


Contactor Relays

DIL Contactors - EATON - MOELLER

Mini Contactor Relays DILE - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$19.57
7+$17.75
13+$17.36
19+$17.16
26+$17.00
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Contactors
Application
  Mini Contactors for Motors and Resistive Loads
Subrange
  DILEM contactors
Utilization category
  AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
 
  >
Notes
  Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Connection technique
  Screw terminals
Description
  With auxiliary contact
Pole
  3 pole
Rated operational current
   
AC-3
   
380 V 400 V
IeA9
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA22
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW2.2
380 V 400 V
PkW4
660 V 690 V
PkW4
AC-4
   
220 V 230 V
PkW1.5
380 V 400 V
PkW3
660 V 690 V
PkW3
Contacts
   
N/C = Normally closed
  1 NC
Contact sequence
  >
For use with
  …DILE
Actuating voltage
  230 V 50/60 Hz
Voltage AC/DC
  AC operation
Technical data
General
Standards
  IEC/EN 60947, VDE 0660, CSA, UL
Lifespan, mechanical; Coil 50/60 Hz
Operationsx 1067
Lifespan, mechanical
Operationsx 10610
Maximum operating frequency
   
Mechanical
 Ops./h9000
electrical (Contactors without overload relay)
  Page 05/070
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +50
Enclosed
 °C- 25 - 40
Mounting position
  As required, except vertical with terminals A1/A2 at the bottom
Mounting position
  >
Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Basic unit without auxiliary contact module
   
Main contacts, make contacts
 g10
Main contacts Make/break contacts
 g10/8
Basic unit with auxiliary contact module
   
Main contacts make contact
 g 
Make
 g10
Auxiliary contacts Make/break contacts
 g20/20
Degree of Protection
  IP20
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Weight
 kg0.2
Terminal capacity of auxiliary and main contacts
   
Screw terminals
   
Solid
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
 AWG18 - 14
Terminal screw
  M3.5
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Max. tightening torque
 Nm1.2
Main conducting paths
Rated impulse withstand voltage
UimpV AC6000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC690
Safe isolation to EN 61140
   
between coil and contacts
 V AC300
between the contacts
 V AC300
Making capacity (cos ϕ to IEC/EN 60947)
 A110
Breaking capacity
   
220 V 230 V
 A90
380 V 400 V
 A90
500 V
 A64
660 V 690 V
 A42
Short-circuit protection maximum fuse
   
Type “2” coordination
gL/gGA10
Type “1” coordination
gL/gGA20
AC
AC-1
   
Rated operational current
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA22
at 50 °C
Ith =IeA20
at 55 °C
Ith =IeA19
enclosed
IthA16
Notes
  At maximum permissible ambient air temperature.
Conventional free air thermal current, 1 pole
   
Notes
  At maximum permissible ambient air temperature.
open
IthA50
enclosed
IthA40
AC-3
   
Rated operational current
   
Open, 3-pole: 50 – 60 Hz
   
Notes
  At maximum permissible ambient air temperature.
220 V 230 V
IeA9
240 V
IeA9
380 V 400 V
IeA9
415 V
IeA9
440V
IeA9
500 V
IeA6.4
660 V 690 V
IeA4.8
Motor rating
PkWh 
220 V 230 V
PkW2.2
240V
PkW2.5
380 V 400 V
PkW4
415 V
PkW4.3
440 V
PkW4
500 V
PkW4
660 V 690 V
PkW4
AC-4
   
Rated operational current
   
Open, 3-pole: 50 – 60 Hz
   
Notes
  At maximum permissible ambient air temperature.
220 V 230 V
IeA6.6
240 V
IeA6.6
380 V 400 V
IeA6.6
415 V
IeA6.6
440 V
IeA6.6
500 V
IeA5
660 V 690 V
IeA3.4
Motor rating
PkWh 
220 V 230 V
PkW1.5
240 V
PkW1.8
380 V 400 V
PkW3
415 V
PkW3.1
440 V
PkW3
500 V
PkW3
660 V 690 V
PkW3
DC
Rated operational current open
   
DC-1
   
12 V
IeA20
24 V
IeA20
60 V
IeA20
110 V
IeA20
220 V
IeA20
DC - 3
   
12 V
IeA8
24 V
IeA8
60 V
IeA4
110 V
IeA3
DC - 5
   
12 V
IeA2.5
24 V
IeA2.5
60 V
IeA2.5
110 V
IeA1.5
220 V
IeA0.3
Current heat losses (3- or 4-pole)
   
to Ith
 W2
at Ie to AC-3/400 V
 W0.5
Magnet systems
Voltage tolerance
   
AC operated
   
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pick-upx Uc0.8 - 1.1
Dual-frequency coil 50/60 Hz
Pick-upx Uc0.85 - 1.1
Power consumption
   
AC operation
   
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pick-upVA25
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pick-upW22
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
SealingVA4.6
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
SealingW1.3
Dual-frequency coil 50/60 Hz at 50 Hz
Pick-upVA30
Dual-frequency coil 50/60 Hz at 50 Hz
Pick-upW26
Dual-frequency coil 50/60 Hz at 50 Hz
SealingVA5.4
Dual-frequency coil 50/60 Hz at 50 Hz
SealingW1.6
Dual-frequency coil 50/60 Hz at 60 Hz
Pick-upVA29
Dual-frequency coil 50/60 Hz at 60 Hz
Pick-upW24
Dual-frequency coil 50/60 Hz at 60 Hz
SealingVA3.9
Dual-frequency coil 50/60 Hz at 60 Hz
SealingW1.1
Duty factor
  % DF100
Switching times at 100 % Uc
   
Make contact
 ms 
Closing delay
 ms 
Closing delay min.
 ms14
Closing delay max.
 ms21
Opening delay
 ms 
Opening delay min.
 ms8
Opening delay max.
 ms18
Closing delay with top mounting auxiliary contact
 msmax. 45
Reversing contactors
   
Changeover time at 110 % Uc
   
Changeover time min.
 ms16
Changeover time max.
 ms21
Arcing time at 690 V AC
 msmax. 12
Coil
   
Lifespan, mechanical; Coil 50/60 Hz
 x 1067
Auxiliary contacts
Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module
  Yes
Rated impulse withstand voltage
UimpV AC6000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC600
Safe isolation to EN 61140
   
between coil and auxiliary contacts
 V AC300
between the auxiliary contacts
 V AC300
Rated operational current
   
AC-15
   
220 V 240 V
IeA6
380 V 415 V
IeA3
500 V
IeA1.5
DC L/R >
1: Overload relay
2: Suppressor
3: Auxiliary contact modules
Enclosure totally insulated
>
Normal AC induction motor
Operating characteristics
Switch on: from stop
Switch off: during run
Electrical characteristics:
Switch on:up to 6 x Rated motor current
Switch off:up to 1 x Rated motor current
Utility category
100 % AC-3
Typical Applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
fan
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevator
Air-conditioning systems
General drives for manufacturing and processing machines
>
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Switching duty for non-motor loads, 3-pole, 4-pole
Operating characteristics
Non-inductive or slightly inductive loads
Electrical characteristics
Make: 1 x rated current
Break: 1 x rated current
Utilization category
100 % AC-1
Typical applications
Electric heat
>
Short-time loading, 3-pole
Time interval between two loading cycles: 15 minutes
Dimensions
>
>
2DILE-… + MVDILE + …DILE
2DILE-…-G + MVDILE + …DILE
CAD data
>Product-specific CAD data
>3D Preview

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or