DILMC115(RAC240) 239736 EATON MOELLER Contactor, 3p, 55kW/400V/AC3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILMC115(RAC240) 239736 EATON MOELLER Contactor, 3p, 55kW/400V/AC3

DILMC115(RAC240)

239736

EATON - MOELLER

Available

Ship on today

Contactor, 3p, 55kW/400V/AC3

More details


Contactor Relays

DIL Contactors - EATON - MOELLER

DIL Contactors up to 170A - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$231.57
2+$226.99
*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Contactors
Application
  Contactors for Motors
Subrange
  Contactors up to 170 A, 3 pole
Utilization category
  AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
 
  >
Notes
  Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Connection technique
  Spring-loaded terminals
Description
  Spring-cage terminals on auxiliary and control circuit terminals
Pole
  3 pole
Rated operational current
   
AC-3
   
380 V 400 V
IeA115
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA160
enclosed
IthA115
Conventional free air thermal current, 1 pole
   
open
IthA325
enclosed
IthA285
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW37
380 V 400 V
PkW55
660 V 690 V
PkW90
AC-4
   
220 V 230 V
PkW17
380 V 400 V
PkW28
660 V 690 V
PkW43
Contact sequence
  >
Instructions
  Contacts to EN 50 012.
Auxiliary current, coil connections with spring-cage connection technology.
Main current connections with screw terminals.
integrated suppressor circuit in actuating electronics
Can be combined with auxiliary contact
  DILM150-XHIC(V)..
DILM1000-XHIC..
Voltage AC/DC
  AC operation
Technical data
General
Standards
  IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
   
AC operated
Operationsx 10610
DC operated
Operationsx 10610
Operating frequency, mechanical
   
AC operated
Operations/h 3600
DC operated
Operations/h 3600
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +60
Enclosed
 °C- 25 - 40
Storage
 °C- 40 - 80
Mounting position
  >>
Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g10
Auxiliary contacts
   
N/O contact
 g7
N/C contact
 g5
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g10
Auxiliary contacts
   
N/O contact
 g7
N/C contact
 g5
Degree of Protection
  IP00
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Weight
   
AC operated
 kg2
DC operated
 kg2.1
Terminal capacity main cable
   
Flexible with ferrule
 mm21 x (10 - 95)
2 x (10 - 70)
Stranded
 mm21 x (16 - 95)
2 x (16 - 70)
Solid or stranded
 AWG8…3/0
Flat conductor
Lamellenzahl x Breite x Dickemm2 x (6 x 16 x 0.8)
Main cable connection screw/bolt
  M10
Tightening torque
 Nm14
Tool
   
Main cable
   
Hexagon socket-head spanner
SWmm5
Terminal capacity control circuit cables
   
Solid
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
 AWG18 - 14
Tool
   
Stripping length
 mm10
Screwdriver blade width
 mm3.5
Main conducting paths
Rated impulse withstand voltage
UimpV AC8000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC690
Safe isolation to EN 61140
   
between coil and contacts
 V AC690
between the contacts
 V AC690
Making capacity (p.f. to IEC/EN 60947)
   
 
Up to 690 VA1610
Breaking capacity
   
220 V 230 V
 A1150
380 V 400 V
 A1150
500 V
 A1150
660 V 690 V
 A1100
Short-circuit rating
   
Short-circuit protection maximum fuse
   
Type “2” coordination
   
400 V
gG/gL 500 VA250
690 V
gG/gL 690 VA250
Type “1” coordination
   
400 V
gG/gL 500 VA250
690 V
gG/gL 690 VA250
AC
AC-1
   
Rated operational current
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA160
at 50 °C
Ith =IeA142
at 55 °C
Ith =IeA135
at 60 °C
Ith =IeA130
enclosed
IthA115
Conventional free air thermal current, 1 pole
   
open
IthA325
enclosed
IthA285
AC-3
   
Rated operational current
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA115
240 V
IeA115
380 V 400 V
IeA115
415 V
IeA115
440V
IeA115
500 V
IeA115
660 V 690 V
IeA93
380 V 400 V
IeA115
Motor rating
PkWh 
220 V 230 V
PkW37
240V
PkW40
380 V 400 V
PkW55
415 V
PkW70
440 V
PkW75
500 V
PkW85
660 V 690 V
PkW90
AC-4
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA55
240 V
IeA55
380 V 400 V
IeA55
415 V
IeA55
440 V
IeA55
500 V
IeA55
660 V 690 V
IeA45
Motor rating
PkWh 
220 V 230 V
PkW17
240 V
PkW19
380 V 400 V
PkW28
415 V
PkW33
440 V
PkW35
500 V
PkW40
660 V 690 V
PkW43
DC
Rated operational current, open
   
DC-1
   
60 V
IeA160
110 V
IeA160
220 V
IeA90
440 V
IeA4.5
DC-3
   
60 V
IeA160
110 V
IeA160
220 V
IeA40
440 V
IeA1
DC-5
   
60 V
IeA160
110 V
IeA160
220 V
IeA40
440 V
IeA1
Current heat loss
3-pole at Ith
 W25.8
Current heat loss at Ie to AC-3/400 V
 W18.9
Impedance per pole
 mΩ0.6
Magnet systems
Voltage tolerance
 x Uc 
AC operated
Pick-upx Uc0.8 - 1.15
Drop-out voltage AC operated
Drop-outx Uc0.25 - 0.6
DC operated
Pick-upx Uc0.7 - 1.2
DC operated
Drop-outx Uc0.15 - 0.6
Notes
  at least smoothed two-phase bridge rectifier or three-phase rectifier
Power consumption of the coil in a cold state and 1.0 x Uc
   
50 Hz
Pick-upVA180
50 Hz
SealingVA3.1
50 Hz
SealingW2.1
60 Hz
Pick-upVA170
60 Hz
SealingVA3.1
60 Hz
SealingW2.1
50/60 Hz
Pick-upVA170
170
50/60 Hz
SealingVA3.1
3.1
50/60 Hz
SealingW2.1
DC operated
Pick-upW149
DC operated
SealingW2.1
Duty factor
  % DF100
Switching times at 100 % Uc (approximate values)
   
Main contacts
   
AC operated
   
Closing delay
 ms28 - 33
Opening delay
 ms35 - 41
DC operated
 ms 
Closing delay
 ms35
Opening delay
 ms30
Arcing time
 ms15
Permissible residual current with actuation of A1 - A2 by the electronics (with 0 signal).
 mA>
1: Overload relay
2: Suppressor
3: Auxiliary contact modules
>
on the side: 2 x DILM820-XHI(V)11-SI; 2 x DILM820-XHI(V)11-SA
on the side: 2 x DILM1000-XHI(V)11-SI; surface mounting: 1 x DILM150-XHIA22
on the side: 2 x DILM1000-XHI(V)11-SI; surface mounting: 1 x DILM150-XHIA11
on the side: 2 x DILM1000-XHI(V)11-SA; surface mounting: 1 x DILM150-XHI (4 pole)
on the side: 2 x DILM1000-XHI(V)11-SA; surface mounting: 1 x DILM150-XHI (2 pole)
>
Squirrel-cage motor
Operating characteristics
Starting:from rest
Stopping:after attaining full running speed
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 1 x rated motor current
Utilization category
100 % AC-3
Typical applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
Fans
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevators
Air conditioning system
General drives in manufacturing and processing machines
>
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Dimensions
>
Contactor with auxiliary contact module
>
distance at side to earthed parts: 10 mm
DILM80…DILM170
DILMC80…DILMC150
DILMF80…DILMF150
CAD data
>Product-specific CAD data
>3D Preview

Datasheet - PDF

Title:Language:Size:Type:
pdf-XTCEC115G00B Contactor, 3p, 55kW/400V/AC3 - EATON - DILMC115RAC240 - 239736English617 Kbytespdf-XTCEC115G00B Contactor, 3p, 55kW/400V/AC3 - EATON - DILMC115RAC240 - 239736

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review