DILM80(380V50/60HZ) 239411 XTCE080F00AR EATON ELECTRIC Contactor, 3p, 37kW/400V/AC3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM80(380V50/60HZ) 239411 XTCE080F00AR EATON ELECTRIC Contactor, 3p, 37kW/400V/AC3

DILM80(380V50/60HZ)

239411

XTCE080F00AR

EATON-MOELLER

Contactor, 3p, 37kW/400V/AC3

Power Contactor Screw connection 3 poles 80 A 37 kW 400 V

Contactor, 3 pole, 380 V 400 V 37 kW, 380 V 50/60 Hz, AC operation, Screw terminals

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors up to 170A

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Contactor, 3 pole, 380 V 400 V 37 kW, 380 V 50/60 Hz, AC operation, Screw terminals
Contactor, Application: Contactors for Motors, Contactors up to 170 A, 3 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 80 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 110 A, enclosed: Ith= 80 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 225 A, enclosed: Ith= 200 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 25 kW, 380 V 400 V: P= 37 kW, 660 V 690 V: P= 63 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 11.5 kW, 380 V 400 V: P= 20 kW, 660 V 690 V: P= 26 kW, Can be combined with auxiliary contact: DILM150-XHI(V).., DILM1000-XHI(V).., Instructions: Contacts to EN 50 012., Voltage AC/DC: AC operation

Delivery program

Product range
Contactors
Application
Contactors for Motors
Subrange
Contactors up to 170 A, 3 pole
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3/AC-3e: Normal AC induction motors: Starting, switching off while running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
0000SPC-571
Notes
Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Connection technique
Screw terminals
Number of poles
3 pole
Rated operational current
AC-3Notes
At maximum permissible ambient temperature (open.)
Also tested according to AC-3e.
AC-3380 V 400 V [Ie]
80 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
110 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 Hzenclosed [Ith]
80 A
AC-1Conventional free air thermal current, 1 poleopen [Ith]
225 A
AC-1Conventional free air thermal current, 1 poleenclosed [Ith]
200 A
Max. rating for three-phase motors, 50 - 60 Hz
AC-3220 V 230 V [P]
25 kW
AC-3380 V 400 V [P]
37 kW
AC-3660 V 690 V [P]
63 kW
AC-4220 V 230 V [P]
11.5 kW
AC-4380 V 400 V [P]
20 kW
AC-4660 V 690 V [P]
26 kW
Contact sequence
210S045
Instructions
Contacts to EN 50 012.
Can be combined with auxiliary contact
DILM150-XHI(V)…
DILM1000-XHI(V)…
Actuating voltage
380 V 50/60 Hz
Voltage AC/DC
AC operation
Connection to SmartWire-DT
no
Frame size
4

Technical data

General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanicalAC operated [Operations]
5.7 x 106
Operating frequency, mechanicalAC operated [Operations/h]
3600
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-25 - +60 °C
Ambient temperatureEnclosed
- 25 - 40 °C
Ambient temperatureStorage
- 40 - 80 °C
Mounting position
210N017210N018
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msMain contactsN/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/O contact
7 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/C contact
5 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mountedHalf-sinusoidal shock, 10 msMain contactsN/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mountedHalf-sinusoidal shock, 10 msAuxiliary contactsN/O contact
7 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mountedHalf-sinusoidal shock, 10 msAuxiliary contactsN/C contact
5 g
Degree of Protection
IP00
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Altitude
Max. 2000 m
WeightAC operated
2.18 kg
Screw connector terminalsTerminal capacity main cableFlexible with ferrule
1 x (10 - 70)
2 x (10 - 50) mm2
Screw connector terminalsTerminal capacity main cableStranded
1 x (16 - 70)
2 x (16 - 50) mm2
Screw connector terminalsTerminal capacity main cableSolid or stranded
single 8…3/0, double 8…2/0 AWG
Screw connector terminalsTerminal capacity main cableFlat conductor [Lamellenzahl x Breite x Dicke ]
2 x (6 x 16 x 0.8) mm
Screw connector terminalsTerminal capacity main cableStripping length
24 mm
Screw connector terminalsTerminal capacity main cableTerminal screw
M10
Screw connector terminalsTerminal capacity main cableTightening torque
14 Nm
Screw connector terminalsTerminal capacity main cableToolHexagon socket-head spanner [SW]
5 mm
Screw connector terminalsTerminal capacity control circuit cablesSolid
1 x (0.75 - 4)
2 x (0.75 - 2.5) mm2
Screw connector terminalsTerminal capacity control circuit cablesFlexible with ferrule
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Screw connector terminalsTerminal capacity control circuit cablesSolid or stranded
18 - 14 AWG
Screw connector terminalsTerminal capacity control circuit cablesStripping length
10 mm
Screw connector terminalsTerminal capacity control circuit cablesTerminal screw
M3.5
Screw connector terminalsTerminal capacity control circuit cablesTightening torque
1.2 Nm
Screw connector terminalsTerminal capacity control circuit cablesToolPozidriv screwdriver
2 Size
Screw connector terminalsTerminal capacity control circuit cablesToolStandard screwdriver
0.8 x 5.5
1 x 6 mm
Main conducting paths
Rated impulse withstand voltage [Uimp]
8000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V AC
Rated operational voltage [Ue]
690 V AC
Safe isolation to EN 61140between coil and contacts
690 V AC
Safe isolation to EN 61140between the contacts
690 V AC
Making capacity (p.f. to IEC/EN 60947) [Up to 690 V]
1120 A
Breaking capacity220 V 230 V
800 A
Breaking capacity380 V 400 V
800 A
Breaking capacity500 V
800 A
Breaking capacity660 V 690 V
650 A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination400 V [gG/gL 500 V]
160 A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination690 V [gG/gL 690 V]
160 A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination400 V [gG/gL 500 V]
250 A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination690 V [gG/gL 690 V]
200 A
AC
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
110 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 50 °C [Ith=Ie]
98 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 55 °C [Ith=Ie]
94 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith=Ie]
90 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 Hzenclosed [Ith]
80 A
AC-1Rated operational currentConventional free air thermal current, 1 poleopen [Ith]
225 A
AC-1Rated operational currentConventional free air thermal current, 1 poleenclosed [Ith]
200 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 HzNotes
At maximum permissible ambient temperature (open.)
Also tested according to AC-3e.
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
80 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz240 V [Ie]
80 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
80 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz415 V [Ie]
80 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz440V [Ie]
80 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz500 V [Ie]
80 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
65 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
80 A
AC-3Motor rating [P]220 V 230 V [P]
25 kW
AC-3Motor rating [P]240V [P]
27.5 kW
AC-3Motor rating [P]380 V 400 V [P]
37 kW
AC-3Motor rating [P]415 V [P]
48 kW
AC-3Motor rating [P]440 V [P]
51 kW
AC-3Motor rating [P]500 V [P]
58 kW
AC-3Motor rating [P]660 V 690 V [P]
63 kW
AC-4Open, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
40 A
AC-4Open, 3-pole: 50 – 60 Hz240 V [Ie]
40 A
AC-4Open, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
40 A
AC-4Open, 3-pole: 50 – 60 Hz415 V [Ie]
40 A
AC-4Open, 3-pole: 50 – 60 Hz440 V [Ie]
40 A
AC-4Open, 3-pole: 50 – 60 Hz500 V [Ie]
40 A
AC-4Open, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
27 A
AC-4Motor rating [P]220 V 230 V [P]
11.5 kW
AC-4Motor rating [P]240 V [P]
13 kW
AC-4Motor rating [P]380 V 400 V [P]
20 kW
AC-4Motor rating [P]415 V [P]
24 kW
AC-4Motor rating [P]440 V [P]
25 kW
AC-4Motor rating [P]500 V [P]
29 kW
AC-4Motor rating [P]660 V 690 V [P]
26 kW
DC
Rated operational current, openDC-160 V [Ie]
110 A
Rated operational current, openDC-1110 V [Ie]
110 A
Rated operational current, openDC-1220 V [Ie]
70 A
Current heat loss
3 pole, at Ith(60°)
11.4 W
Current heat loss at Ieto AC-3/400 V
9 W
Impedance per pole
0.6 mΩ
Magnet systems
Voltage toleranceAC operated [Pick-up]
0.8 - 1.1 x Uc
Voltage toleranceDrop-out voltage AC operated [Drop-out]
0.3 - 0.6 x Uc
Power consumption of the coil in a cold state and 1.0 x US50/60 Hz [Pick-up]
372
328 VA
Power consumption of the coil in a cold state and 1.0 x US50/60 Hz [Sealing]
37.1
22.6 VA
Power consumption of the coil in a cold state and 1.0 x US50/60 Hz [Sealing]
5.8 W
Duty factor
100 % DF
Changeover time at 100 % US(recommended value)Main contactsAC operatedClosing delay
14 - 20 ms
Changeover time at 100 % US(recommended value)Main contactsAC operatedOpening delay
9 - 14 ms
Changeover time at 100 % US(recommended value)Arcing time
15 ms
Changeover time at 100 % US(recommended value)Permissible residual current with actuation of A1 - A2 by the electronics (with 0 signal).
≦ 1 mA
Lifespan, mechanical; Coil 50/60 Hz
Mechanical lifespan at 50 Hz approx. 30% lower than under “General” x 106
Electromagnetic compatibility (EMC)
Emitted interference
to EN 60947-1
Interference immunity
to EN 60947-1

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
80 A
Heat dissipation per pole, current-dependent [Pvid]
3 W
Equipment heat dissipation, current-dependent [Pvid]
9 W
Static heat dissipation, non-current-dependent [Pvs]
5.8 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching ([email protected] [AAB718015])
Rated control supply voltage Us at AC 50HZ
380 - 380 V
Rated control supply voltage Us at AC 60HZ
380 - 380 V
Rated control supply voltage Us at DC
0 - 0 V
Voltage type for actuating
AC
Rated operation current Ie at AC-1, 400 V
110 A
Rated operation current Ie at AC-3, 400 V
80 A
Rated operation power at AC-3, 400 V
37 kW
Rated operation current Ie at AC-4, 400 V
40 A
Rated operation power at AC-4, 400 V
20 kW
Rated operation power NEMA
44.7 kW
Modular version
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Number of normally closed contacts as main contact
0
Number of main contacts as normally open contact
3

Characteristics

210O154
Accessories
1: Overload relay
2: Suppressor
3: Auxiliary contact modules
Side mounting auxiliary contacts
2100DRW-296
possible variants at auxiliary contact module fitting options
on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
Characteristic curve
2100DIA-7
Squirrel-cage motor
Operating characteristics
Starting:from rest
Stopping:after attaining full running speed
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 1 x rated motor current
Utilization category
100 % AC-3
Typical applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
Fans
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevators
Air conditioning system
General drives in manufacturing and processing machines
Characteristic curve
2100DIA-8
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Characteristic curve
210U038
Switching conditions for non-motor consumers, 3 pole, 4 pole
Operating characteristics
Non inductive and slightly inductive loads
Electrical characteristics
Switch on: 1 x rated operational current
Switch off: 1 x rated operational current
Utilization category
100 % AC-1
Typical examples of application
Electric heat

Dimensions

210X203
Contactor with auxiliary contact module
210T016
distance at side to earthed parts: 10 mm
DILM80…DILM170
DILMC80…DILMC150
DILMF80…DILMF150

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.