DILL18(24V50HZ) 104404 XTPAXSR24V50H EATON ELECTRIC Contactor, 3p, 18A, for lamp load (HQL) View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILL18(24V50HZ) 104404 XTPAXSR24V50H EATON ELECTRIC Contactor, 3p, 18A, for lamp load (HQL)

DILL18(24V50HZ)

104404

XTPAXSR24V50H

EATON-MOELLER

Contactor, 3p, 18A, for lamp load (HQL)

DILL18(24V50HZ)

Lamp load contactor, 24 V 50 Hz, 220 V 230 V: 18 A, Contactors for lighting systems

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors up to 170A

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $78.88
Unit price: $78.88

Quantity Price
1+$78.88
2+$67.94
3+$64.39
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Lamp load contactor, 24 V 50 Hz, 220 V 230 V: 18 A, Contactors for lighting systems
Lamp load contactors, Application: Contactors for lighting systems, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, Rated operational current 380 V 400 V: Ie = 21 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie = 40 A, Actuating voltage: 24 V 50 Hz, Standards: IEC/EN 60947, VDE 0660, UL, CSA, Degree of Protection: IP00

Delivery program

Product range
DILL Lighting contactors
Application
Contactors for lighting systems
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Rated operational current
AC-5a220 V 230 V [Ie]
18 A
AC-5a380 V 400 V [Ie]
18 A
AC-5b220 V 230 V [Ie]
21 A
AC-5b380 V 400 V [Ie]
21 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
40 A
Contact sequence
210S045
Actuating voltage
24 V 50 Hz
Note

Switchgear for lighting systems
DIL L12 L18 L20 M7 M9 M12 M17 M25 M32 M40 M50
Permissible compensation capacitance Cmax [mF] 470 470 470 47 80 100 220 330 470 470 500
Filament lamp Ie [A] 14 21 27 6 7.5 10 14 21 27 33 42
Mercury blended lamps Ie [A] 12 16 23 5 6.5 8.5 12 16 23 30 38
Fluorescent lamps, conventional -reactor – starter – connection Ie [A] 20 26 35 9 10 15 20 26 35 41 45
Fluorescent lamps, conventional -reactor – starter – connection Ie [A] 20 26 35 5.5 8 13 15 22.5 29 36 47
Fluorescent lamps, duo circuit
(series compensated)
Ie [A] 12 18 20 5 6.5 8.5 12 17.5 22.5 28 35
electronic upstream devices and LED lamps Ie [A] 12 18 20 3.5 6 10 12 17.5 20 25 30
High-pressure mercury-arc lamps Ie [A] 12 18 20 3.5 6 10 12 17.5 20 25 30
Metal-halide lamps Ie [A] 12 18 20 3.5 6 10 12 17.5 20 25 30
Low-pressure sodium lamps Ie [A] 7.5 10 12 3 4 6 7.5 10 12 15 22
DIL M65 M80 M95 M115 M150 M185A M225A M250A M300A M400A M500A
Permissible compensation capacitance Cmax [mF] 500 550 620 830 970 2055 2300 2600 3000 3250 3500
Filament lamp Ie [A] 55 67 79 95 125 153 187 208 349 332 415
Mercury blended lamps Ie [A] 45 65 67 80 110 123 150 167 200 266 332
Fluorescent lamps, conventional -reactor – starter – connection Ie [A] 55 95 100 125 145 207 237 263 300 375 525
Fluorescent lamps, conventional -reactor – starter – connection Ie [A] 59 71 95 100 138 186 213 236 270 338 473
Fluorescent lamps, duo circuit
(series compensated)
Ie [A] 45.5 56 66.5 80.5 105 130 158 175 210 280 350
electronic upstream devices and LED lamps Ie [A] 36 55 60 80 95 138 158 175 200 250 350
High-pressure mercury-arc lamps Ie [A] 36 55 60 80 95 138 158 175 200 250 350
Metal-halide lamps Ie [A] 36 55 60 80 95 138 158 175 200 250 350
Low-pressure sodium lamps Ie [A] 25 35 40 50 70 100 11 123 140 175 245
In compensated lamps, the sum of the capacitances must not exceed the contactors' max. permissible capacitor load (Cmax)!
The values in the table are for each contact in the contactors.

Technical data

General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanicalAC operated [Operations]
1 x 106
Operating frequency, mechanicalAC operated [Operations/h]
60
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-25 - +60 °C
Ambient temperatureEnclosed
- 25 - 40 °C
Ambient temperatureStorage
- 40 - 80 °C
Mounting position
210N017210N019
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msMechanical shock resistance
6.9 g
Degree of Protection
IP00
Altitude
Max. 2000 m
WeightAC operated
0.42 kg
Main conducting paths
Rated impulse withstand voltage [Uimp]
8000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V AC
Rated operational voltage [Ue]
690 V AC
Making capacity
350 A
Breaking capacity [380 … 400 V]
250 A
Lifespan, electrical [Operations]
10000
Short-circuit protection maximum fuse400 V [gG/gL 500 V]
100 A
AC
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
40 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith=Ie]
35 A
AC-5a operation220 V 230 V [Ie]
18 A
AC-5a operation380 V 400 V [Ie]
18 A
AC-5b operation220 V 230 V [Ie]
21 A
AC-5b operation380 V 400 V [Ie]
21 A
AC-5b operation380 V 400 V [Ie]
21 A
Electric lampsFilament bulbs
21 A
Electric lampsMercury blended lamps
16 A
Electric lampsFluorescent lamp loadConventional reactor starter circuit
26 A
Electric lampsFluorescent lamp loadDuo circuit
26 A
Electric lampsElectronic upstream devices
18 A
Electric lampsHigh-pressure mercury vapour lamps
18 A
Electric lampsMetal-halide lamps
18 A
Electric lampsHigh-pressure sodium lamps
18 A
Electric lampsLow-pressure sodium lamps
10 A
Electric lampsMaximum permissible compensation capacitance
470 µF
Additional technical data
like the contactar [DIL]
M25
Rating data for approved types
Switching capacityGeneral use
35 A
Short Circuit Current RatingBasic RatingSCCR
5 kA
Short Circuit Current RatingBasic Ratingmax. Fuse
125 A
Short Circuit Current RatingBasic Ratingmax. CB
125 A
Short Circuit Current Rating480 V High FaultSCCR (fuse)
100 kA
Short Circuit Current Rating480 V High Faultmax. Fuse
100 Class J A
Short Circuit Current Rating480 V High FaultSCCR (CB)
22 kA
Short Circuit Current Rating480 V High Faultmax. CB
32 A
Short Circuit Current Rating600 V High FaultSCCR (fuse)
100 kA
Short Circuit Current Rating600 V High Faultmax. Fuse
100 Class J A
Short Circuit Current Rating600 V High FaultSCCR (CB)
22 kA
Short Circuit Current Rating600 V High Faultmax. CB
32 A
Special Purpose RatingsIncandescent Lamps (Tungsten)480V 60Hz 3phase, 277V 60Hz 1phase
35 A
Special Purpose RatingsIncandescent Lamps (Tungsten)600V 60Hz 3phase, 347V 60Hz 1phase
35 A

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
21 A
Heat dissipation per pole, current-dependent [Pvid]
1 W
Equipment heat dissipation, current-dependent [Pvid]
3 W
Static heat dissipation, non-current-dependent [Pvs]
2.1 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching ([email protected] [AAB718015])
Rated control supply voltage Us at AC 50HZ
24 - 24 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
0 - 0 V
Voltage type for actuating
AC
Rated operation current Ie at AC-1, 400 V
18 A
Rated operation current Ie at AC-3, 400 V
0 A
Rated operation power at AC-3, 400 V
0 kW
Rated operation current Ie at AC-4, 400 V
0 A
Rated operation power at AC-4, 400 V
0 kW
Rated operation power NEMA
0 kW
Modular version
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Number of normally closed contacts as main contact
0
Number of main contacts as normally open contact
3

Approvals

Product Standards
IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking
UL File No.
E29096
UL Category Control No.
NLDX
CSA File No.
012528
CSA Class No.
3211-04
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Dimensions

2110DIM-7
210T014
distance at side to earthed parts: 6 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.