M22-K01 216378 M22-K01Q EATON ELECTRIC Contact element, 1 N/C, front mount, 6. contact, screw connection View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

M22-K01 216378 M22-K01Q EATON ELECTRIC Contact element, 1 N/C, front mount, 6. contact, screw connection

M22-K01

216378

M22-K01Q

EATON-MOELLER

Contact element, 1 N/C, front mount, 6. contact, screw connection

M22-K01

Contact element, Screw terminals, Front fixing, 1 NC, 24 V 3 A, 220 V 230 V 240 V 6 A

More details


Low-voltage industrial components > Auxiliary contact block

Auxiliary Control and Signalling Elements

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $4.23
Unit price: $4.23

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



EL-Nummer (Norway)
4355364
Contact element, Screw terminals, Front fixing, 1 NC, 24 V 3 A, 220 V 230 V 240 V 6 A
Contact element, Standard/Approval: UL/CSA, IEC, Construction size: NZM1/2/3/4, Connection technique: Screw terminals, Fixing: Front fixing, Contacts N/C = Normally closed: 1 NC, Contacts Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1: mm 4.8, Maximum travel: mm 5.7, Minimum force for positive opening: N 15, Degree of Protection: IP20, Connection to SmartWire-DT: no, Connection type: Single contact, Description of HIA trip-indicating auxiliary contact: General trip indication '+', when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current., Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Not in combination with switch-disconnector PN…, Marking on switch: HIA, Labeling in FI-Block: HIAFI., If the trip-indicating auxiliary switch in the fault current block is used, the NC contacts operates as a N/O contact and the NC contact operates as an N/O contact., Description standard auxiliary contact HIN: Switching with the main contacts Used for indicating and interlocking tasks., Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Marking on switch: HIN., On combination with remote operator NZM-XR... the right mounting location of standard auxiliary contact HIN can be fitted only with individual contacts., For use with: NZM1(-4), 2(-4), 3(-4), 4(-4), PN1(-4), 2(-4), 3(-4), N(S)1(-4), 2(-4), 3(-4), 4(-4), Standards: IEC 60947-5-1

Delivery program

Product range
Accessories
Basic function accessories
Contact elements
Accessories
Auxiliary contact
Accessories
Standard auxiliary contact, trip-indicating auxiliary switch
Standard/Approval
UL/CSA, IEC
Construction size
NZM1/2/3/4
Connection technique
Screw terminals
Fixing
Front fixing
Degree of Protection
IP20
Connection to SmartWire-DT
no
For use with
NZM1(-4), 2(-4), 3(-4), 4(-4)
PN1(-4), 2(-4), 3(-4)
N(S)1(-4), 2(-4), 3(-4), 4(-4)
Approval
000Z425
Contacts
N/C = Normally closed
1 NC
Notes
= safety function, by positive opening to IEC/EN 60947-5-1
Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1
[mm]
4.8
Maximum travel [mm]
5.7
Minimum force for positive opening [ N]
15
Contact sequence
116S041
Contact travel diagram, stroke in connection with front element
Contact diagram
116U023
Configuration
116Q003
Connection type
Single contact
Description of HIA trip-indicating auxiliary contact
General trip indication '+', when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current.
Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker.
Any combinations of the auxiliary contact types are possible.
Not in combination with switch-disconnector PN…
Marking on switch: HIA
Labeling in FI-Block: HIAFI.
If the trip-indicating auxiliary switch in the fault current block is used, the NC contacts operates as a N/O contact and the NC contact operates as an N/O contact.
Description standard auxiliary contact HIN
Switching with the main contacts Used for indicating and interlocking tasks.
Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.
Any combinations of the auxiliary contact types are possible.
Marking on switch: HIN.
On combination with remote operator NZM-XR... the right mounting location of standard auxiliary contact HIN can be fitted only with individual contacts.
Connection technique
Screw terminals
Notes

The following can be clipped into the switches:

  • NZM1: a standard auxiliary contact
  • NZM2: up to two M22-(C)K… standard auxiliary contacts
  • NZM3: up to three M22-(C)K… standard auxiliary contacts
  • NZM4: up to three M22-(C)K… standard auxiliary contacts

Any combinations of the auxiliary contact types are possible.

Marking on switch: HIN

In combination with remote operator NZM‐XR… only single contacts can be fitted to some installation locations of the standard auxiliary contact.

NZM2: Only single contact can be fitted in left installation location of standard auxiliary contact.

NZM3: Only single contact can be fitted in installation locations of standard auxiliary contact.

NZM4: Only single contact can be fitted in right installation location of standard auxiliary contact.

Technical data

General
Standards
IEC 60947-5-1
Lifespan, mechanical [Operations]
> 5 x 106
Operating frequency [Operations/h]
≦ 3600
Actuating force
≦ 5 n
Operating torque (screw terminals)
≦ 0.8 Nm
Degree of Protection
IP20
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-25 - +70 °C
Mechanical shock resistance to IEC 60068-2-27 Shock duration 11 ms, half-sinusoidal
> 30 g
Terminal capacitiesSolid
0.75 - 2.5 mm2
Terminal capacitiesStranded
0.5 - 2.5 mm2
Terminal capacitiesFlexible with ferrule
0.5 - 1.5 mm2
Contacts
Rated impulse withstand voltage [Uimp]
6000 V AC
Rated insulation voltage [Ui]
500 V
Overvoltage category/pollution degree
III/3
Control circuit reliabilityat 24 V DC/5 mA [HF]
< 10-7(i.e. 1 failure to 107operations) Fault probability
Control circuit reliabilityat 5 V DC/1 mA [HF]
< 5 x 10-6(i.e. 1 failure in 5 x 106operations) Fault probability
Max. short-circuit protective deviceFuseless
PKZM0-10/FAZ-B6/1 Type
Max. short-circuit protective deviceFuse [gG/gL]
10 A
Switching capacity
Rated operational current [Ie]AC-15115 V [Ie]
6 A
Rated operational current [Ie]AC-15220 V 230 V 240 V [Ie]
6 A
Rated operational current [Ie]AC-15380 V 400 V 415 V [Ie]
4 A
Rated operational current [Ie]AC-15500 V [Ie]
2 A
Rated operational current [Ie]DC-1324 V [Ie]
3 A
Rated operational current [Ie]DC-1342 V [Ie]
1.7 A
Rated operational current [Ie]DC-1360 V [Ie]
1.2 A
Rated operational current [Ie]DC-13110 V [Ie]
0.6 A
Rated operational current [Ie]DC-13220 V [Ie]
0.3 A
Lifespan, electricalAC-15230 V/0.5 A [Operations]
1.6 x 106
Lifespan, electricalAC-15230 V/1.0 A [Operations]
1 x 106
Lifespan, electricalAC-15230 V/3.0 A [Operations]
0.7 x 106
Lifespan, electricalDV-1312 V/2.8 A [Operations]
1.2 x 106
Auxiliary contacts
Rated operational voltage [Ue]Rated operational voltage [Ue]
500 V AC
Rated operational voltage [Ue]Rated operational voltage, max. [Ue]
220 V DC
Conventional thermal current [Ith= Ie]
4 CSA
Rated operational current [Ie]Different rated operational currentswhen used as auxiliary contact for NZM circuit-breaker
M22-(C)K10(01)M22-CK11(02)(20)XHIV
bei AC = 50/60 Hz
Bemessungsbetriebsstrom
AC-15115 VIeA444
230 VIeA444
400 VIeA2-2
500 VIeA1-1
DC-1324 VIeA333
42 VIeA1.711.5
60 VIeA1.20.80.8
110 VIeA0.60.50.5
220 VIeA0.30.20.2
Rated conditional short-circuit current [Iq]
1 kA
Short-circuit protectionmax. fuse
10 A gG/gL
Short-circuit protectionMax. miniature circuit-breaker
FAZ-B6/B1 A
Operating times

Early-make time of the HIV compared to the main contacts during with make and break switching.

(switch times with manual operation):

NZM1, PN1, N(S)1: ca. 20 ms

NZM2, PN2, N(S)2: ca. 20 ms

NZM3, PN3, N(S)3: ca. 20 ms

NZM4, N(S)4: approx. 90 ms, the HIV switch earlyOffswitchingnotforward.

Terminal capacitiesSolid or flexible conductor, with ferrule
1 x (0,75 - 2,5)
2 x (0,75 - 2,5) mm2
UL/CSARated operational current [Ie]
5 A – 600 V AC
1 A - 250 V DC A

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
6 A
Heat dissipation per pole, current-dependent [Pvid]
0.11 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+70 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block ([email protected] [AKN342013])
Number of contacts as change-over contact
0
Number of contacts as normally open contact
0
Number of contacts as normally closed contact
1
Number of fault-signal switches
0
Rated operation current Ie at AC-15, 230 V
6 A
Type of electric connection
Screw connection
Model
Top mounting and integrable
Mounting method
Front fastening
Lamp holder
None

Approvals

Product Standards
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
012528
CSA Class No.
3211-03
North America Certification
UL listed, CSA certified
Degree of Protection
UL/CSA Type: -

Dimensions

116X101
A = 37.2
123X305
Pushbutton with M22-(C)K…
Pushbutton with M22-(C) LED… + M22-XLED…

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.