NZM4-4-XKV95 281592 EATON MOELLER Connection width extension, 4p, spacing 95mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM4-4-XKV95 281592 EATON MOELLER Connection width extension, 4p, spacing 95mm

NZM4-4-XKV95

281592

EATON - MOELLER

Available

Ship on today

Connection width extension, 4p, spacing 95mm

More details


Circuit Breakers Electrical Power

Circuit-breakers NZM and LZM (Accessories) - EATON - MOELLER

Terminals - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$218.70
2+$214.00
3+$213.01
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Accessories
  Connection width extension
Description
  Five-hole fitting
Number of conductors
  4 pole
Rated current
InA1600
For use with
  NZM4-4, N4-4
Terminal capacities
   
Type of conductor
   
Cu/Al cable
  Cu cable lugs
Terminal capacities
   
flexible
 mm24 x 300
6 x 95 - 240
AWG/kcmil
 mm24 x 600
6 x 000 … 500
Terminal capacities
   
Cu strip (number of segments x width x segment thickness)
 mm2min.10 x 50 x 1.0
Copper busbar width x thickness
Breitemmmax. (2 x) 80 x 10
Notes 

Type contains parts for a terminal located at top or bottom for 3 or 4 pole switches.

Five-hole fitting, for up to nine cable lugs per phase, for example.

Can be fitted to circuit-breaker with screw connection.

Phase isolator included as standard.

Distance between pole centers: 95 mm

Installation conditions for current transformer up to 130 mm width with 80 mm busbar width.

4 mm holes predrilled for control circuit terminal.

Contains hole for large cover NZM4(-4)‑XKSAV.

Design verification as per IEC/EN 61439(Show features)(Hide features)
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Connection vane/phase spreader (EC002019)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Connection vane/phase spreader ([email protected] [ACN990009])
Suitable for number of poles
  4
Dimensions
IL01210014Z (AWA1230-2241) Connection extension for NZM4
 
>>

Datasheet - PDF