LZMB2-4-A160/100-I 111930 EATON ELECTRIC Circuit-breaker, 4 p, 160A, 100A, in 4th pole View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

LZMB2-4-A160/100-I 111930 EATON ELECTRIC Circuit-breaker, 4 p, 160A, 100A, in 4th pole

LZMB2-4-A160/100-I

111930

EATON-MOELLER

Circuit-breaker, 4 p, 160A, 100A, in 4th pole

More details


Circuit Breakers LZM

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery programme
Product range
Circuit-breaker
Protective function
System and cable protection
Standard/Approval
IEC
Installation type
Fixed
Release system
Thermomagnetic release
Construction size
LZM2
Description
Set value in neutral conductor is synchronous with set value Ir of main pole.
Number of poles
4 pole
Standard equipment
Screw connection
Switching capacity
400/415 V 50 Hz
Icu kA 25
Rated current = rated uninterrupted current
Rated current = rated uninterrupted current
In= Iu A 160
Neutral conductor
% of phase conductor CSA 60
Neutral conductor protection
Reduced neutral conductor protection
Setting range
Overload trip
General
Standards
IEC/EN 60947, VDE 0660
Protection against direct contact
Finger and back-of-hand proof to VDE 0106 part 100
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
g 20 (half-sinusoidal shock 20 ms)
Safe isolation to EN 61140
Between auxiliary contacts and main contacts
V AC 500
between the auxiliary contacts
V AC 300
Weight
kg 3.5
Mounting position

Vertical and 90° in all directions
Basic equipment
Box terminal - - -
Screw connection -
accessory consideration
Box terminals - -
Screw connection - -
Tunnel terminal
connection on rear
Strip terminal - - -
Round copper conductor
Box terminal
Solid
mm2 1 x (4 - 16)
2 x (4 - 16)
Stranded
mm2 1 x (25 - 185)
2 x (25 - 70)
Tunnel terminal
Solid
mm2 1 x 16
Stranded
mm2
Stranded
mm2 1 x (25 - 185)
Bolt terminal and rear-side connection
Direct on the switch
Solid
mm2 1 x (4 - 16)
2 x (4 - 16)
Stranded
mm2 1 x (25 - 185)
2 x (25 - 70)
Al conductors, Cu cable
Solid
mm2 1 x 16
Stranded
mm2
Stranded
mm2 1 x (25 - 185)
Bolt terminal and rear-side connection
Flat copper strip, with holes
min. mm 2 x 16 x 0.8
Flat copper strip, with holes
max. mm 10 x 16 x 0.8
Cu strip (number of segments x width x segment thickness)
Box terminal
min. mm 2 x 9 x 0.8
max. mm 10 x 16 x 0.8
Bolt terminal and rear-side connection
Flat copper strip, with holes
min. mm 2 x 16 x 0.8
Flat copper strip, with holes
max. mm 10 x 16 x 0.8
Copper busbar (width x thickness)
mm
Bolt terminal and rear-side connection
Screw connection
M8
Direct on the switch
min. mm 16 x 5
max. mm 20 x 5
Control cables
mm2 1 x (0.75 - 2.5)
2 x (0.75 - 1.5)
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
Rated operational current for specified heat dissipation
In A 160
Equipment heat dissipation, current-dependent
Pvid W 38.4
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716010])
Rated permanent current Iu
A 160
Rated voltage
V 690 - 690
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
kA 25
Overload release current setting
A 125 - 160
Adjustment range short-term delayed short-circuit release
A 0 - 0
Adjustment range undelayed short-circuit release
A 960 - 1600
Integrated earth fault protection
No
Type of electrical connection of main circuit
Screw connection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Switched-off indicator available
No
With under voltage release
No
Number of poles
4
Position of connection for main current circuit
Front side
Type of control element
Rocker lever
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP20
Characteristics
IL01206012Z circuit-breaker LZMB2, switch-disconnector LN2
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.