CLS6-C25/1N 263672 EATON ELECTRIC Over current switch, 25A, 1pole+N, type C characteristic View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CLS6-C25/1N 263672 EATON ELECTRIC Over current switch, 25A, 1pole+N, type C characteristic

CLS6-C25/1N

263672

EATON-MOELLER

Over current switch, 25A, 1pole+N, type C characteristic

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: CLS6-C25/1N-DE 247649

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
Rated operational current for specified heat dissipation
In A 25
Heat dissipation per pole, current-dependent
Pvid W 0
Equipment heat dissipation, current-dependent
Pvid W 3.5
Static heat dissipation, non-current-dependent
Pvs W 0
Heat dissipation capacity
Pdiss W 0
Operating ambient temperature min.
°C -25
Operating ambient temperature max.
°C 55
linear, per +1 °C, results in a 0.5% reduction of current carrying capacity
Technical data ETIM 6.0
Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)
Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) ([email protected] [AAB905011])
Release characteristic
C
Number of poles (total)
2
Number of protected poles
2
Nominal rated current
A 25
Nominal rated voltage
V 230
Rated short-circuit breaking capacity Icn EN 60898 at 230 V
kA 6
Rated short-circuit breaking capacity Icn EN 60898 at 400 V
kA 6
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V
kA 0
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V
kA 0
Voltage type
AC
Current limiting class
3
Frequency
Hz 50 - 60
Concurrently switching N-neutral
Yes
Suitable for flush-mounted installation
No
Over voltage category
3
Pollution degree
2
Width in number of modular spacings
2
Built-in depth
mm 70.5
Additional equipment possible
Yes
Degree of protection (IP)
IP20

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE EATON EN.pdf 51 Mbytes
CLS6-C25/1N 263672 263672.pdf 133 Kbytes   CLS6-C25/1N  263672 263672.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.