NZMN1-4-A25 281247 EATON MOELLER Circuit-breaker, 4p, 25A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZMN1-4-A25 281247 EATON MOELLER Circuit-breaker, 4p, 25A

NZMN1-4-A25

281247

EATON - MOELLER

Available

Ship on today

Circuit-breaker, 4p, 25A

More details


Circuit Breakers Electrical Power

Circuit-breakers NZM - EATON - MOELLER

Compact circuit-breaker, up to 160A - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$354.53
2+$350.72
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Circuit-breaker
Protective function
  System and cable protection
Standard/Approval
  IEC
Installation type
  Fixed
Release system
  Thermomagnetic release
Construction size
  NZM1
Description
  Set value in neutral conductor is synchronous with set value Ir of main pole.
Number of poles
  4 pole
Standard equipment
  Box terminal
Switching capacity
   
400/415 V 50 Hz
IcukA50
Rated current = rated uninterrupted current
   
Rated current = rated uninterrupted current
In = IuA25
Neutral conductor
% of phase conductorCSA100
Setting range
   
Overload trip
   
General
Standards
  IEC/EN 60947
Protection against direct contact
  Finger and back of hand proof to VDE 0106 Part 100
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Ambient temperature, storage
 °C- 40 - + 80
Operation
 °C-25 - +70
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
 g20 (half-sinusoidal shock 20 ms)
Safe isolation to EN 61140
   
Between auxiliary contacts and main contacts
 V AC500
between the auxiliary contacts
 V AC300
Mounting position
  
Vertical and 90° in all directions
 
Switching of one pole via two series contacts Switching of one pole via three series contacts
 
Basic equipment        
 Box terminal  - - -
 Screw connection -   
Accessories        
 Box terminal -   -
 Screw connection  - - 
 Tunnel terminal    
 Connection on rear    
 Flat conductor terminal - - - 
Round copper conductor
   
Box terminal
   
Solid
 mm21 x (10 - 16)
2 x (6 - 16)
Stranded
 mm21 x (25 - 70)
2 x 25
Tunnel terminal
   
Solid
 mm21 x 16
Stranded
 mm2 
Stranded
 mm21 x (25 - 95)
Bolt terminal and rear-side connection
   
Direct on the switch
   
Solid
 mm21 x (10 - 16)
2 x (10 - 16)
Stranded
 mm21 x (25 - 35)
2 x (25 - 35)
Al conductors, Cu cable
   
 
   
Solid
 mm21 x 16
Stranded
 mm2 
Stranded
 mm21 x (25 - 95)
Cu strip (number of segments x width x segment thickness)
   
Box terminal
   
 
min.mm2 x 9 x 0.8
 
max.mm9 x 9 x 0.8
Copper busbar (width x thickness)
mm  
Bolt terminal and rear-side connection
   
Screw connection
  M6
Direct on the switch
   
 
min.mm12 x 5
 
max.mm16 x 5
Control cables
   
 
 mm21 x (0.75 - 2.5)
2 x (0.75 - 1.5)
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA25
Equipment heat dissipation, current-dependent
PvidW8.78
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716010])
Rated permanent current Iu
 A25
Rated voltage
 V690 - 690
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
 kA50
Overload release current setting
 A20 - 25
Adjustment range short-term delayed short-circuit release
 A0 - 0
Adjustment range undelayed short-circuit release
 A350 - 350
Integrated earth fault protection
  No
Type of electrical connection of main circuit
  Frame clamp
Device construction
  Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
  No
DIN rail (top hat rail) mounting optional
  Yes
Number of auxiliary contacts as normally closed contact
  0
Number of auxiliary contacts as normally open contact
  0
Number of auxiliary contacts as change-over contact
  0
Switched-off indicator available
  No
With under voltage release
  No
Number of poles
  4
Position of connection for main current circuit
  Front side
Type of control element
  Rocker lever
Complete device with protection unit
  Yes
Motor drive integrated
  No
Motor drive optional
  No
Degree of protection (IP)
  IP20
Characteristics
IL01203004Z (AWA1230-1913) Circuit-breaker, Switch-Disconnector
 
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or