IZMX40N3-P40W 149820 EATON ELECTRIC Circuit-breaker, 3p, 4000 A, withdrawable View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IZMX40N3-P40W 149820 EATON ELECTRIC Circuit-breaker, 3p, 4000 A, withdrawable

IZMX40N3-P40W

149820

EATON-MOELLER

Circuit-breaker, 3p, 4000 A, withdrawable

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery programme
Product range
  Air circuit-breakers/switch-disconnectors
Product range
  Open circuit-breakers
Current Range
  Up to 4000 A
Protective function
  Professional protection
Installation type
  Withdrawable
Construction size
  IZMX40
Release system
  Electronic release
Standard/Approval
  IEC
Number of poles
  3 pole
Degree of Protection
  IP20, IP55 with protective cover, IP41 door sealing frame
 
  suitable for zone selectivity
suitable for communication
with integrated system monitor
with integrated test possibility
with graphic LCD color display
optionally fittable by user with comprehensive accessories
Rated current = rated uninterrupted current
In = IuA4000
up to 440 V 50/60 Hz
IcukA85
up to 440 V 50/60 Hz
IcskA85
Overload release, min.
IrA2000
Overload release, max.
IrA4000
Non-delayed
General
Standards
  IEC/EN 60947
Ambient temperature
   
Storage
ϑ°C-25 - +70 (device with LCD-display -20 - +70)
Operating (open)
 °C-25 - +70 (device with LCD-display -20 - +70)
Mounting position
  
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA4000
Equipment heat dissipation, current-dependent
PvidW880
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716010])
Rated permanent current Iu
 A4000
Rated voltage
 V690 - 690
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
 kA85
Overload release current setting
 A2000 - 4000
Adjustment range short-term delayed short-circuit release
 A8000 - 40000
Adjustment range undelayed short-circuit release
 A8000 - 48000
Integrated earth fault protection
  No
Type of electrical connection of main circuit
  Rail connection
Device construction
  Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
  No
DIN rail (top hat rail) mounting optional
  No
Number of auxiliary contacts as normally closed contact
  0
Number of auxiliary contacts as normally open contact
  0
Number of auxiliary contacts as change-over contact
  2
Switched-off indicator available
  Yes
With under voltage release
  No
Number of poles
  3
Position of connection for main current circuit
  Back side
Type of control element
  Push button
Complete device with protection unit
  Yes
Motor drive integrated
  No
Motor drive optional
  Yes
Degree of protection (IP)
  IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.