IZMX40H3-P32W 149851 EATON ELECTRIC Circuit-breaker, 3p, 3200 A, withdrawable View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IZMX40H3-P32W 149851 EATON ELECTRIC Circuit-breaker, 3p, 3200 A, withdrawable

IZMX40H3-P32W

149851

EATON-MOELLER

Circuit-breaker, 3p, 3200 A, withdrawable

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery program
Product range
Air circuit-breakers/switch-disconnectors
Product range
Open circuit-breakers
Current Range
Up to 4000 A
Protective function
Professional protection
Installation type
Withdrawable
Cassette must be separately ordered.
IZMX-DTP-PTM external voltage measuring module required
Construction size
IZMX40
Release system
Electronic release
Standard/Approval
IEC
Number of poles
3 pole
Degree of Protection
IP20, IP55 with protective cover, IP41 door sealing frame
suitable for zone selectivity
suitable for communication
with integrated system monitor
with integrated test possibility
with graphic LCD color display
optionally fittable by user with comprehensive accessories
Rated current = rated uninterrupted current
In = IuA 3200
up to 440 V 50/60 Hz
IcukA 105
up to 440 V 50/60 Hz
IcskA 105
Overload release, min.
IrA 1600
Overload release, max.
IrA 3200
Non-delayed
Ii = In x … 2 - 12, OFF
Delayed
Isd = Ir x … 2 - 10
Technical data
General
Standards
IEC/EN 60947
Ambient temperature
Storage
ϑ°C -25 - +70 (device with LCD-display -20 - +70)
Operating (open)
°C -25 - +70 (device with LCD-display -20 - +70)
Mounting position
Utilization category
B
Degree of Protection
IP20, IP55 with protective cover, IP41 door sealing frame
Direction of incoming supply
as required
Main conducting paths
Rated current = rated uninterrupted current
In = IuA 3200
Rated uninterrupted current at 50 °C
IuA 3200
Rated uninterrupted current at 60 °C
IuA 3200
Rated uninterrupted current at 70 °C
IuA 75
Rated impulse withstand voltage
UimpV AC 12000
Rated operational voltage
UeV AC 690
Use in IT electrical power networks up to U = 440 V
IITkA 57.6
Overvoltage category/pollution degree
III/3
Rated insulation voltage
UiV 1000
Switching capacity
Rated short-circuit making capacity
Icm
up to 440 V 50/60 Hz
IcmkA 231
up to 690 V 50/60 Hz
IcmkA 166
Rated short-time withstand current 50/60 Hz
t = 1 s
IcwkA 85
t = 3 s
IcwkA 66
Rated short-circuit breaking capacity Icn
Icn
IEC/EN 60947 operating sequence Icu O-t-CO
up to 240 V 50/60 Hz
IcukA 105
up to 440 V 50/60 Hz
IcukA 105
up to 690 V 50/60 Hz
IcukA 75
IEC/EN 60947 operating sequence Ics O-t-CO-t-CO
up to 240 V 50/60 Hz
IcskA 105
up to 440 V 50/60 Hz
IcskA 105
up to 690 V 50/60 Hz
IcskA 75
Operating times
Closing delay via spring release
ms 35
Total opening delay via shunt release
ms 22
Total opening delay via undervoltage release
ms 37
Total opening delay on non-delayed short-circuit release (up to complete arc quenching)
ms 45
Maximum operating frequency
Operations/h 60
Heat dissipation at rated current In
Withdrawable units (switch with cassette)
W 560
Weight
Withdrawable
3-pole
kg 70
4-pole
kg 86
Cassette
3 pole
kg 27
4 pole
kg 35
Terminal capacities
Copper bar
Withdrawable units
Black
mm 3 x 80 x 10
These are values used in separate switchgear. The actual values will depend on the temperature around the circuit-breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.


Permissible continuous current for circuit‐breakers operating in switchboards at various internal ambient temperatures. The switchboard’s internal ambient temperature should be estimated using the calculation methods of IEC regulation.

Notes
IZMX-DTP-PTM external voltage measuring module required
Technical data ETIM 7.0
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716013])
Rated permanent current Iu
A 3200
Rated voltage
V 690 - 690
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
kA 105
Overload release current setting
A 1600 - 3200
Adjustment range short-term delayed short-circuit release
A 6400 - 32000
Adjustment range undelayed short-circuit release
A 6400 - 38400
Integrated earth fault protection
No
Type of electrical connection of main circuit
Rail connection
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
2
With switched-off indicator
Yes
With under voltage release
No
Number of poles
3
Position of connection for main current circuit
Rear
Position of connection for main current circuit
Back side
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.