NZMB2-AF30-NA 269145 EATON ELECTRIC Circuit-breaker, 3p, 30A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZMB2-AF30-NA 269145 EATON ELECTRIC Circuit-breaker, 3p, 30A

NZMB2-AF30-NA

269145

EATON-MOELLER

Circuit-breaker, 3p, 30A

NZMB2-AF30-NA

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Circuit Breakers NZM

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $350.51
Unit price: $350.51

Quantity Price
1+$350.51
2+$350.51
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Circuit-breaker, 3p, 30A
Circuit-breaker NZM2, 3 pole, Switching capacity SCCR 480Y/277 V 60 Hz( Icu ): 25 kA, Switching capacity SCCR 600Y/347 V 60 Hz( Icu ): 18 kA, Switching capacity SCCR 480 V 60 Hz( Icu ): 25 kA, Rated current = rated uninterrupted current (In = Iu ): 30 A, Installation type: Fixed, Screw connection, Standard/Approval: UL/CSA, IEC, Protective function: System and cable protection

Delivery program

Product range
Circuit-breaker
Protective function
System and cable protection
Standard/Approval
UL/CSA, IEC
Release system
Thermomagnetic release
Installation type
Fixed
Description
Switches conform to UL/CSA as well as the IEC regulations. IEC switching performance values are contained on the rating plate.
Fixed overload releases Ir
Frame size
NZM2
Number of poles
3 pole
Standard equipment
Screw connection
Switching capacity
SCCR 480Y/277 V 60 Hz [Icu]
25 kA
SCCR 480 V 60 Hz [Icu]
25 kA
SCCR 600Y/347 V 60 Hz [Icu]
18 kA
Rated current = rated uninterrupted current [In= Iu]
Rated current = rated uninterrupted current [In= Iu]
30 A
Setting range
Overload trip[Ir]
30 - 30 A
Short-circuit releases[Irm]Non-delayed[Ii= Inx …]
350 A fixed

Technical data

General
Standards
IEC/EN 60947
Protection against direct contact
Finger and back of hand proof to VDE 0106 Part 100
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureAmbient temperature, storage
- 40 - + 70 °C
Ambient temperatureOperation
-25 - +70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140Between auxiliary contacts and main contacts
500 V AC
Safe isolation to EN 61140between the auxiliary contacts
300 V AC
Weight
2.345 kg
Mounting positionMounting position
Vertical and 90° in all directions
With XFI earth-fault release:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in unit
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90° right/left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Direction of incoming supply
as required
Degree of protectionDevice
In the operating controls area: IP20 (basic degree of protection)
Degree of protectionEnclosures
With insulating surround: IP40
With door coupling rotary handle: IP66
Degree of protectionTerminations
Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Circuit-breakers
Rated surge voltage invariability [Uimp]Main contacts
8000 V
Rated surge voltage invariability [Uimp]Auxiliary contacts
6000 V
Rated operational voltage [Ue]
440 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V
Use in unearthed supply systems
≦ 440 V
Switching capacity
Rated short-circuit making capacity [Icm]240 V [Icm]
63 kA
Rated short-circuit making capacity [Icm]400/415 V [Icm]
53 kA
Rated short-circuit making capacity [Icm]440 V 50/60 Hz [Icm]
53 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]240 V 50/60 Hz [Icu]
30 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]400/415 V 50/60 Hz [Icu]
25 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]440 V 50/60 Hz [Icu]
25 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]240 V 50/60 Hz [Ics]
30 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]400/415 V 50/60 Hz [Ics]
25 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]440 V 50/60 Hz [Ics]
18.5 kA
Rated short-circuit breaking capacity Icn[Icn]Maximum low-voltage h.b.c. fuse
355 A gG/gL
Rated short-circuit breaking capacity Icn[Icn]
Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Technical data that diverge from products for the IEC market
Switching capacity of NA switches (UL489, CSA 22.2 No. 5.1)
Short-circuit current rating SCCR
SCCR 240 V 60 Hz [Icu]
35 kA
Technical data that diverge from products for the IEC market
Switching capacity of NA switches (UL489, CSA 22.2 No. 5.1)
Short-circuit current rating SCCR
SCCR 480Y/277 V 60 Hz [Icu]
25 kA
Technical data that diverge from products for the IEC market
Switching capacity of NA switches (UL489, CSA 22.2 No. 5.1)
Short-circuit current rating SCCR
SCCR 480 V 60 Hz [Icu]
25 kA
Technical data that diverge from products for the IEC market
Switching capacity of NA switches (UL489, CSA 22.2 No. 5.1)
Short-circuit current rating SCCR
SCCR 600Y/347 V 60 Hz [Icu]
18 kA
Utilization category to IEC/EN 60947-2
A
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) [Operations]
20000
Lifespan, electricalAC-1400 V 50/60 Hz [Operations]
7500
Lifespan, electricalAC--3415 V 50/60 Hz [Operations]
6500
Lifespan, electricalMax. operating frequency
120 Ops/h
Total break time at short-circuit
< 10 ms
Terminal capacity
Standard equipment
Screw connection
Round copper conductorBox terminalSolid
1 x (12 … 6) mm2
Round copper conductorBox terminalStranded
1 x (4 … 350) mm2
Round copper conductorTunnel terminalSolid
1 x 16 mm2
Round copper conductorTunnel terminalStrandedStranded
1 x (4 … 350) mm2
Round copper conductorBolt terminal and rear-side connectionDirect on the switchSolid
1 x (11 … 6) mm2
Round copper conductorBolt terminal and rear-side connectionDirect on the switchStranded
1 x (4 … 3/0) mm2
Al conductors, Cu cableTunnel terminalSolid
1 x 16 mm2
Al conductors, Cu cableBolt terminal and rear-side connectionFlat copper strip, with holes [min.]
2 x 16 x 0.8 mm
Al conductors, Cu cableBolt terminal and rear-side connectionFlat copper strip, with holes [max.]
10 x 16 x 0.8 mm
Cu strip (number of segments x width x segment thickness)Box terminal [min.]
2 x 9 x 0.8 mm
Cu strip (number of segments x width x segment thickness)Box terminal [max.]
10 x 16 x 0.8 mm
Cu strip (number of segments x width x segment thickness)Bolt terminal and rear-side connectionFlat copper strip, with holes [min.]
2 x 16 x 0.8 mm
Cu strip (number of segments x width x segment thickness)Bolt terminal and rear-side connectionFlat copper strip, with holes [max.]
10 x 16 x 0.8 mm
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionScrew connection
M8
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionDirect on the switch [min.]
16 x 5 mm
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionDirect on the switch [max.]
20 x 5 mm
Control cables
1 x (18 … 14)
2 x (18 … 16) mm2

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
30 A
Equipment heat dissipation, current-dependent [Pvid]
8.48 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+70 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716013])
Rated permanent current Iu
30 A
Rated voltage
440 - 440 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25 kA
Overload release current setting
30 - 30 A
Adjustment range short-term delayed short-circuit release
0 - 0 A
Adjustment range undelayed short-circuit release
350 - 350 A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Screw connection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
With under voltage release
No
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Rocker lever
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP20

Approvals

Product Standards
UL 489; CSA-C22.2 No. 5-09; IEC 60947-2; CE marking
UL File No.
E31593
UL Category Control No.
DIVQ
CSA File No.
022086
CSA Class No.
1432-01
North America Certification
UL listed, CSA certified
Specially designed for North America
Yes
Suitable for
Feeder circuits, branch circuits
Current Limiting Circuit-Breaker
Yes
Max. Voltage Rating
600Y/347 V, 480 V
Degree of Protection
IEC: IP20; UL/CSA Type: -

Characteristics

Characteristic curve
123U176
Characteristic curve
1230DIA-85
Characteristic curve
1230DIA-80

Dimensions

123X312
① Blow out area, minimum clearance to adjacent parts
② Minimum clearance to adjacent parts
123X341

Datasheet - PDF

Title: Size: Type:
NZMB2-AF30-NA 269145 EN_269145.pdf 585 Kbytes   NZMB2-AF30-NA  269145 EN_269145.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.