IZM32N3-V20F 123951 EATON MOELLER Automatic switch, 3P, 2000A, fixed

IZM32N3-V20F

123951

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Automatic switch, 3P, 2000A, fixed

More details


Circuit-breakers IZM - EATON - MOELLER

Circuit Breakers IZM32 - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

Up to 35% discount for registered clients. * This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.
EXPRESS quotation request, you will get an answer in a few minutes

IZM32N3-V20F 123951 EATON MOELLER Automatic switch, 3P, 2000A, fixed

Enter your contact details and submit your request, you will be notified by email with a quotation. You simply finish your order and you will receive the products.






* Required fields

or 

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Air circuit-breakers/switch-disconnectors
Product range
  Open circuit-breakers
Current Range
  over 4000 A
Protective function
  Selective operation
Installation type
  Fixed
Construction size
  IZM32
Release system
  Electronic release
Standard/Approval
  IEC
Number of poles
  3 pole
Degree of Protection
  IP20, IP55 with protective cover, IP41 with door sealing frame
Rated current = rated uninterrupted current
In = IuA2000
Breaking capacity Icu = Ics to 440 V 50/60 Hz
IcukA85
Breaking capacity Ics to 440 V 50/60 Hz
IcskA85
Overload release, min.
IrA800
Overload release, max.
IrA2000
Non-delayed
Ii = In x … 2 - 10, OFF
Delayed
Isd = Ir x … 2 - 10
Notes 

Including rear connection main terminals and secondary terminal blocks according to ordered breaker options.

Technical data
General
Standards
  IEC/EN 60947
Ambient temperature
   
Storage
ϑ°C-25 - +70 (device with LCD-display -20 - +70)
Operating (open)
 °C-25 - +70 (device with LCD-display -20 - +70)
Mounting position
  >
 
  >
Utilization category
  B
Degree of Protection
  IP20, IP55 with protective cover, IP41 with door sealing frame
Direction of incoming supply
  as required
Main conducting paths
Rated current = rated uninterrupted current
In = IuA2000
Rated uninterrupted current at 50 °C
IuA2000
Rated uninterrupted current at 60 °C
IuA2000
Rated uninterrupted current at 70 °C
IuA2000
Rated impulse withstand voltage
UimpV AC8000
Rated operational voltage
UeV AC690
Use in IT electrical power networks up to U = 440 V
IITkA28
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV1000
Switching capacity
Rated short-circuit making capacity
Icm  
up to 440 V 50/60 Hz
IcmkA178
up to 690 V 50/60 Hz
IcmkA179
Rated short-time withstand current 50/60 Hz
   
t = 1 s
IcwkA85
t = 3 s
IcwkA65
Rated short-circuit breaking capacity Icn
Icn  
IEC/EN 60947 operating sequence Icu O-t-CO
   
up to 240 V 50/60 Hz
IcukA85
up to 440 V 50/60 Hz
IcukA85
up to 690 V 50/60 Hz
IcukA85
IEC/EN 60947 operating sequence Ics O-t-CO-t-CO
   
up to 240 V 50/60 Hz
IcskA85
up to 440 V 50/60 Hz
IcskA85
up to 690 V 50/60 Hz
IcskA85
Operating times
   
Closing delay via spring release
 ms30
Break times
 ms40
Total opening delay via shunt release
 ms35
Total opening delay via undervoltage release
 ms35/70
Total opening delay on non-delayed short-circuit release (up to complete arc quenching)
 ms35
Maximum operating frequency
Operations/h 60
Heat dissipation at rated current In
   
Fixed mounting
 W190
Withdrawable units (switch with cassette)
 W380
Weight
Fixed mounting
   
3-pole
 kg68
4-pole
 kg86
Withdrawable
   
3-pole
 kg80
4-pole
 kg102
Cassette
   
3 pole
 kg34
4 pole
 kg38
Terminal capacities
Copper bar
   
Fixed mounting
   
Black
 mm3 x 5 x 100
Withdrawable units
   
Black
 mm3 x 5 x 100
 
  

Permissible continuous current for circuit‐breakers operating in switchboards at various internal ambient temperatures. The switchboard’s internal ambient temperature should be estimated using the calculation methods of IEC regulation.

Other technical data (sheet catalogue)
  >Tripping characteristics for universal and selective protection
>Notes - tripping characteristics
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
Dimensions
>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields