KS95-NZM7 059775 EATON MOELLER Cable lug, 95mm², narrow type View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

KS95-NZM7 059775 EATON MOELLER Cable lug, 95mm², narrow type

KS95-NZM7

059775

EATON - MOELLER

Available

Ship on today

Cable lug, 95mm², narrow type

More details


Control Cabinets Switch Boxes Distribution Enclosures

Enclosures- EATON - MOELLER

CI insulated enclosures - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$15.33
13+$13.32
25+$13.01
37+$12.85
50+$12.74
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Number of conductors
  3/4 pole
Accessories
  Cable lugs
For use with
  NZM2(-4), PN2(-4), N2(-4)
Description
  Not UL/CSA approved.
Narrow tubular cable lugs for switchgear connections.
When using without cover NZM2 (-4)-XKSA, the cable lug must be insulated.
Terminal capacity
 mm295
Instructions For detailed specifications regarding suitable types of conductors and the required crimping tool: See Heading Engineering.
Technical data
Engineering
Engineering notes
  

In order to crimp cable lugs when using stranded conductors, e.g., VDE 0295 Class 2 and rounded stranded sector-shaped conductors, you will need a Klauke K22, HK60/22, or EK22 crimping tool with the following crimping dies:

  • R22/95 for 95 mm2
  • R22/120 for 120 mm2
  • R22/150 for 150 mm2
  • R22/185 for 185 mm2
  • R22/240 for 240 mm2
  • R22/300 for 300 mm2

Flexible conductors are adequate to a limited extent. They must be indent-crimped with a Klauke series 13 or series 25 crimping die.

Design verification as per IEC/EN 61439(Show features)(Hide features)
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
Installation, isolation and connection material (EG000047) / Crimp cable lug for copper conductors according to DIN 46235 (EC001050)
Electric engineering, automation, process control engineering / Electrical insulation and connecting material / Lug, conductor sleeve, connector / Crimp cable lug for copper conductors ([email protected] [AKN512010])
Bolt dimension metric (M..)
  0
Connecting angle
  Straight
Number of fixing holes
  1
Code digit
  0
Nominal cross section
 mm²95
Surface protection
  Tinned
Dimensions
IL01219049Z (AWA1230-2046) Cable lugs-NZM2
 
>>