M22-XAM 229025 M22-XAMQ EATON ELECTRIC Buzzer BA9s.18-30V DC, continuous tone View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

M22-XAM 229025 M22-XAMQ EATON ELECTRIC Buzzer BA9s.18-30V DC, continuous tone

M22-XAM

229025

M22-XAMQ

EATON-MOELLER

Buzzer BA9s.18-30V DC, continuous tone

M22-XAM

More details


Low-voltage industrial components > Acoustic indicator

Auxiliary Control and Signalling Elements

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $17.40
Unit price: $17.40

Quantity Price
1+$17.40
2+$17.40
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Buzzer BA9s.18-30V DC, continuous tone
Buzzer BA9s, 18-30V, continuous tone, for acoustic device M22-AMC

General specifications
Product name
Eaton Moeller® series M22 Accessory Acoustic indicator
Part no.
M22-XAM
EAN
4015082290252
Product Length/Depth
30 millimetre
Product height
10 millimetre
Product width
10 millimetre
Product weight
0.014 kilogram
Compliances
CE Marked
Certifications
CSA Std. C22.2 No. 14-05
IEC 60947-5
UL 508
EN 60947-5
CSA-C22.2 No. 14-05
CE
CSA File No.: 012528
UL
CSA
UL Category Control No.: NKCR
UL File No.: E29184
CSA Class No.: 3211-03
IEC/EN 60947-5
Product Tradename
M22
Product Type
Accessory
Product Sub Type
Acoustic indicator
Catalog Notes
Positive pin at X1
f = 2300 Hz
Features & Functions
Alarm type
Continuous tone
Continuous tone, 18 - 30 V DC
Loudness
83 dB
General information
Degree of protection
NEMA Other
Voltage type
DC
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Electrical rating
Rated operational voltage (Ue) at AC - max
0 V
Rated operational voltage (Ue) at AC - min
0 V
Rated operational voltage (Ue) at DC - max
30 V
Rated operational voltage (Ue) at DC - min
18 V
Communication
Connection to SmartWire-DT
No
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0.4 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Acoustic indicator (EC001026)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Acoustic alarm unit (ecl@ss13-27-37-12-14 [AKF032019])
Type of acoustic signal
Continuous tone
Loudness
83 dB
Operating voltage AC 50 Hz
0 - 0 V
Operating voltage AC 60 Hz
0 - 0 V
Operating voltage DC
18 - 30 V
Voltage type
DC
Degree of protection (NEMA)
Other

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.