XN-BR-24VDC-D 140071 4520627 EATON ELECTRIC Bus refreshing module XI/ON, 24 V DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

XN-BR-24VDC-D 140071 4520627 EATON ELECTRIC Bus refreshing module XI/ON, 24 V DC

XN-BR-24VDC-D

140071

4520627

EATON-MOELLER

Bus refreshing module XI/ON, 24 V DC

XN-BR-24VDC-D

More details


PLC's > Fieldbus, decentr. periphery - power supply/segment module

Remote I / O Modules XION

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $182.31
Unit price: $182.31

Quantity Price
1+$182.31
2+$161.58
3+$151.26
4+$145.42
6+$139.77
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



EL-Nummer (Norway)
4520627
Bus refreshing module XI/ON, 24 V DC
The XI/ON standard I/O system offers the right I/O solution for every application due to its great modularity and large variety of functions. Pluggable modules, hot-swapping of modules, wiring on the basic module screw or tension spring, modules' mechanical coding. The standard gateways support the CANopen bus systems, PROFIBUS-DP deviceNet and Ethernet.

Delivery program

Function
XI/ON power supply modules
Function
XN Slice module
Short Description
System power supply 24 V DC for generation of power for module bus and gateway (XN-GW-... )
Field power supply module with 24 V DC nominal voltage
For use with
XN-P3T-SBB
XN-P3S-SBB
XN-P4T-SBBC
XN-P4S-SBBC
XN-P3T-SBB-B
XN-P3S-SBB-B
XN-P4T-SBBC-B
XN-P4S-SBBC-B

Technical data

General
Standards
EN 61000-6-2
EN 61000-6-4
EN 61131-2
Potential isolation
Yes, through optocoupler
Ambient temperature
0 - +55 °C
Storage [ϑ]
-25 - +85 °C
Relative humidity
5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C)
Harmful gases
SO2: 10 (rel. humidity < 75%, no condensation)
H2S: 1.0 (rel. humidity < 75 %,no condensation) ppm
Vibration resistance, operating conditions
according to IEC/EN 60068-2-6
Mechanical shock resistance
according to IEC 60068-2-27 g
Continuous shock resistance (IEC/EN 60068-2-29)
According to IEC 60068-2-29
Drop and topple
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
Degree of Protection
IP20
Electromagnetic compatibility (EMC)ESD [Air/contact discharge]
EN 61000-4-2 kV
Electromagnetic compatibility (EMC)Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ]
EN 61100-4-2 V/m
Electromagnetic compatibility (EMC)Burst
EN 61100-4-4
Electromagnetic compatibility (EMC)Surge
EN 61100-4-5
Electromagnetic compatibility (EMC)Radiated RFI
EN 61100-4-6 V
Electromagnetic compatibility (EMC)Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)]
EN 55016-2-3 dB
Electromagnetic compatibility (EMC)Voltage fluctuations/voltage dips
EN 61131-2
Electromagnetic compatibility (EMC)Type test
to EN 61131-2
Approvals
CE, cULus
Other technical data (sheet catalogue)
Supply modules
System supply [Usys]
24 V DC
Coordination type "1" [Usys]
18…30 V DC
Coordination type "2" [Usys]
4.7…5.3 V DC
Field voltage [UL]
24 V DC
Admissible range
18-30 V DC
Rated insulation voltage [Ui]
500 V AC
Residual ripple
According to EN 61131-2; ripple < 5 %
Maximum operating current [IEI]
10 A
Maximum system supply current [IMB]
1.5 A
Number of diagnostic bytes
4
Base module without gateway power supplywithout C connection
2-/3-wire
XN-P3x-SBB-B
Base module without gateway power supplywith C connection
4-wire
XN-P4x-SBBC-B
Power loss [P]
1.3 W
Notes

Permissible range for system supply:

For Usys= 24 V DC: 18 - 30 V DC (to EN 61131‐2)

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
1.3 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
0 °C
Operating ambient temperature max.
+55 °C
Degree of Protection
IP20
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

PLC's (EG000024) / Fieldbus, decentr. periphery - power supply/segment module (EC001600)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - feed and segment module ([email protected] [BAA071013])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
18 - 30 V
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
1
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
System accessory
Yes
Degree of protection (IP)
IP20
Type of electric connection
Screw-/spring clamp connection
With potential separation
Yes
With power supply module
No
Suitable as segment module
Yes
Remote module
No
Fieldbus connection over separate bus coupler possible
Yes
Bus diagnosis possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
No
Front build in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
Category according to EN 954-1
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
12.6 mm
Height
74.1 mm
Depth
55.4 mm

Approvals

Product Standards
UL 508; CSA-C22.2 No. 142; IEC/EN 6113-2; CE marking
UL File No.
E205091
UL Category Control No.
NRAQ, NRAQ7
CSA File No.
UL report applies to both US and Canada
CSA Class No.
2252-01, 2252-81
North America Certification
UL recognized, certified by UL for use in Canada
Specially designed for North America
No
Current Limiting Circuit-Breaker
No
Degree of Protection
IEC: IP20, UL/CSA Type: -

Dimensions

2725DIM-3
Link to sheet catalogue

Datasheet - PDF

Title: Size: Type:
XN-BR-24VDC-D 4520627 140071 EN_140071.pdf 124 Kbytes   XN-BR-24VDC-D 4520627 140071 EN_140071.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.