Product name
Eaton XNE Output module
Product Length/Depth
161.5 millimetre
Product height
74.5 millimetre
Product width
13 millimetre
Product weight
0.064 kilogram
Certifications
CULus
IEC/EN 6113-2
Rated data for terminations according to IEC/EN 60947-7-1
CE
IEC/EN 61000-6-2
IEC/EN 61131-2
IEC/EN 61000-6-4
Product Type
Output module
Catalog Notes
-10/0 to +10 V DC
0.2
0/4 to 20 mA
200 ppm/°C of full-scale value
Switchable as channels
Electric connection type
Plug-in connection
Features
Analog outputs configurable
Output, current
Fieldbus connection over separate bus coupler possible
Output, voltage
Output signal configurable
Current consumption
40 mA, from module bus, Analog input modules
150 mA, from supply terminal
Degree of protection
IP20
NEMA 1
Mounting method
Rail mounting possible
Product category
XNE Slice module
Ambient conditions, mechanical
Drop and topple
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
Shock resistance
Continuous according to IEC/EN 60068-2-29
Mechanical, According to IEC/EN 60068-2-27
Vibration resistance
According to IEC/EN 60068-2-6
Climatic environmental conditions
Ambient operating temperature - min
0 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-25 °C
Ambient storage temperature - max
85 °C
Environmental conditions
Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation)
Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation)
Relative humidity
5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C)
Electro magnetic compatibility
Air discharge
According to EN 61100-4-2
Burst impulse
According to IEC/EN 61000-4-4
Contact discharge
According to EN 61100-4-2
Electromagnetic fields
According to IEC EN 61100-4-2
Emitted interference
230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3)
30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3)
Radiated RFI
IEC/EN 61100-4-6
Surge rating
According to IEC/EN 61000-4-5 Level 4
Voltage dips
According to EN 61131-2 (Voltage fluctuations/voltage dips)
Terminal capacity
0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.25 - 1.5 mm², flexible without ferrule, H07V-K
0.25 - 1.5 mm², solid, H07V-U
0.25 - 0.75 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
Gauge pin
A1 (according to IEC/EN 60947-1)
Stripping length (main cable)
8 mm
Rated operational voltage
24 V DC (supply terminal)
Short-circuit current
40 mA, Analog output modules
Supply voltage at AC, 50 Hz - min
0 V AC
Supply voltage at AC, 50 Hz - max
0 V AC
Supply voltage at DC - min
20.4 V DC
Supply voltage at DC - max
28.8 V DC
Connection type
Push-In spring-cage terminals, Connection design in TOP direction
Protocol
Other bus systems
Frequency
20 Hz (Transfer)
Load resistance
< 450 Ω (Current)
> 1 µF (capacitive load)
< 0.001 h (inductive load)
> 1000 Ω (Voltage)
Measured value representation
Standard/extended range/PA (NE43)
16-bit signed integer
12-bit full range, flush left
Measured variables
Current
Voltage
Number of inputs (analog)
0
Number of outputs (analog)
4
Output current
0/4 - 20 mA
Output voltage
-10 - 10 V DC
Settling time
2 ms, Inductive load, Analog output modules
1 ms, Resistive load, Analog output modules
2 ms, Capacitive load, Analog output modules
Timing cycle
0.1 % Offset error
Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Through optocoupler: yes
Equipment heat dissipation, current-dependent Pvid
3 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
3 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.