060L114366 DANFOSS REFRIGERATION Thermostat View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

060L114366 DANFOSS REFRIGERATION Thermostat

060L114366

DANFOSS REFRIGERATION

Thermostat

KP73 Thermostat M/32

Thermostat, KP73

More details


Home > DANFOSS REFRIGERATION

* Brand new product in its original packaging covered by the warranties and certifications provided by DANFOSS REFRIGERATION

Total price: $126.57
Unit price: $126.57

Quantity Price
1+$126.57
2+$114.76
3+$105.18
4+$99.77
5+$97.04
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Temperature range [°C]: -25 - 15, Reset function: Auto, Contact function: SPDT, Sensor type: Double contact remote sensor, Capillary tube length [mm]: 2000, Enclosure rating IP: IP30

Product details

Gross weight0.444 Kg
Net weight0.37 Kg
Volume1.277 Liter
EAN5702428014892
Gross weight0.444 Kg
Net weight0.37 Kg
Volume1.277 Liter
EAN5702428014892

Amb. Temp. Note80 °C/176 °F for max 120 min
Ambient temperature range [°C] [max]65 °C
Ambient temperature range [°C] [min]-40 °C
Ambient temperature range [°F] [max]150 °F
Ambient temperature range [°F] [min]-40 °F
ApprovalBV
CCC
CE
CMIM
DNV
EAC
GL
LLC CDC EURO-TYSK
LR
LVD
PZH
RINA
RMRS
RoHS China
c UL us UL873, CS C22.2
UKCA
Cap. tube length fraction [in]78 3/4 in
Capillary tube length [mm]2000 mm
Charge typeAdsorption
Contact functionSPDT
Contact ratingAC15=10 A, 400 V
AC1=16 A, 400 V
AC3=16 A, 400 V
DC13=12 W, 220 V
LR=112 A, 400 V
Diff. @ Max. range setting [K] [max]18 K
Diff. @ Max. range setting [K] [min]3.2 K
Diff. @ Max. range setting[°C] [max]18 °C
Diff. @ Max. range setting[°C] [min]3.2 °C
Diff. @ Min. range setting [K] [max]20 K
Diff. @ Min. range setting [K] [min]3.5 K
Diff. @ Min. range setting[°C] [max]20 °C
Diff. @ Min. range setting[°C] [min]3.5 °C
Differential typeAdjustable
Electrical connectionRubber cable gland
Electrical connection size6-14 mm
Electrical spec. standardEN 60947-5
EN 60947 electrical propertiesPollution degree: 3
Rated impulse voltage: 4 kV
Insulation: 400V
Short circuit prot, fuse: 16A
EN 60947 wiring propertiesFlex, ferrules: 0.5-1.5 mm2
Flex, no ferrules: 0.7-2.5 mm2
Solid/stranded: 0.75-2.5 mm2
Enclosure rating IPIP30
Enclosure rating Nema (~)1
EquipmentSensors with double contact
EU RoHS complianceYes
In scope of WEEE and contain batteriesNo
Max. sensor temperature [°C]80 °C
Max. sensor temperature [°F]176 °F
Packing formatMulti pack
Product accessoriesSwitches accessories
Product descriptionThermostat
Product groupSwitches and thermostats
Product Name DescriptionThermostat
Quantity per packing format32 pc
REACH Candidate List substancesLead (CAS no. 7439-92-1)
Reset functionAuto
SCIP dossier no.be15a44e-80b1-41bd-9578-c8ff1cd7b9f3
Sensor size (Ø x L) [in]13/32 x 3 3/8 in
Sensor size (Ø x L) [mm]10 x 85 mm
Sensor typeDouble contact remote sensor
ServiceableNo
Temperature range [°C] [max]15 °C
Temperature range [°C] [min]-25 °C
Temperature range [°F] [max]59 °F
Temperature range [°F] [min]-13 °F
TypeKP73
UL approval file nameE31024
Amb. Temp. Note80 °C/176 °F for max 120 min
Ambient temperature range [°C] [max]65 °C
Ambient temperature range [°C] [min]-40 °C
Ambient temperature range [°F] [max]150 °F
Ambient temperature range [°F] [min]-40 °F
ApprovalBV
CCC
CE
CMIM
DNV
EAC
GL
LLC CDC EURO-TYSK
LR
LVD
PZH
RINA
RMRS
RoHS China
c UL us UL873, CS C22.2
UKCA
Cap. tube length fraction [in]78 3/4 in
Capillary tube length [mm]2000 mm
Charge typeAdsorption
Contact functionSPDT
Contact ratingAC15=10 A, 400 V
AC1=16 A, 400 V
AC3=16 A, 400 V
DC13=12 W, 220 V
LR=112 A, 400 V
Diff. @ Max. range setting [K] [max]18 K
Diff. @ Max. range setting [K] [min]3.2 K
Diff. @ Max. range setting[°C] [max]18 °C
Diff. @ Max. range setting[°C] [min]3.2 °C
Diff. @ Min. range setting [K] [max]20 K
Diff. @ Min. range setting [K] [min]3.5 K
Diff. @ Min. range setting[°C] [max]20 °C
Diff. @ Min. range setting[°C] [min]3.5 °C
Differential typeAdjustable
Electrical connectionRubber cable gland
Electrical connection size6-14 mm
Electrical spec. standardEN 60947-5
EN 60947 electrical propertiesPollution degree: 3
Rated impulse voltage: 4 kV
Insulation: 400V
Short circuit prot, fuse: 16A
EN 60947 wiring propertiesFlex, ferrules: 0.5-1.5 mm2
Flex, no ferrules: 0.7-2.5 mm2
Solid/stranded: 0.75-2.5 mm2
Enclosure rating IPIP30
Enclosure rating Nema (~)1
EquipmentSensors with double contact
EU RoHS complianceYes
In scope of WEEE and contain batteriesNo
Max. sensor temperature [°C]80 °C
Max. sensor temperature [°F]176 °F
Packing formatMulti pack
Product accessoriesSwitches accessories
Product descriptionThermostat
Product groupSwitches and thermostats
Product Name DescriptionThermostat
Quantity per packing format32 pc
REACH Candidate List substancesLead (CAS no. 7439-92-1)
Reset functionAuto
SCIP dossier no.be15a44e-80b1-41bd-9578-c8ff1cd7b9f3
Sensor size (Ø x L) [in]13/32 x 3 3/8 in
Sensor size (Ø x L) [mm]10 x 85 mm
Sensor typeDouble contact remote sensor
ServiceableNo
Temperature range [°C] [max]15 °C
Temperature range [°C] [min]-25 °C
Temperature range [°F] [max]59 °F
Temperature range [°F] [min]-13 °F
TypeKP73
UL approval file nameE31024

Datasheet - PDF

Title: Size: Type:
060L114366 060L114366 EN_060L110166.pdf 246 Kbytes   060L114366  060L114366 EN_060L110166.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.